Bulk sample analysis, 14-22 [name], Manhattan

Machine-extracted title · confidence 42%

Bulk sample analysis report for NYC-DCAS, listing Lab Sample IDs and sample locations.

NYC-WTC_000268233–000268258
Page image
Page image not rendered yet.
The pipeline renders page images incrementally; check back or read the OCR text alongside.
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document

KAM CONSULTANTS 35-40 36th Street Long Island City New York. 11106 Tel: (718)729-1997 Far (718)729-1876

BULK SAMPLE ANALYSIS REPORT

CLIENT: NYC-DCAS BUILDING ADDRESS: 14-22 Reade Street, Manhattan PROJECT#: Client Sample ID# : 35C 36A 363 36C 37A Lab Sample ID# : 010905B-240 010905B-241 010905B-242 010905B-243 010905B-244

Sample Location: Roof'C" Roof'C” Roof'C" Roof'C" Roof"C"

Homogeneity: Yes Yes Yes Yes Yes

Sample Description Roof Membrane Roof Membrane Roof Membrane Roof Membrane Base Flashing 3rd Layer 1st Layer 2niJ Layer 3rd Layer 1 st Layer

Color: Blk Blk Bbe Blk Blk

Texture; Mixed Non Fibrous Non Fibrous Mixed Mixed

Sample Treatment; Acid Digestion Acid Digestion Acid Digestion Acid Digestion Acid Digestion & Ashing & Ashing & Ashing & Ashing & Ashing Asbestos Present; (Type & Percent) <1%CHR ND ND ND L33%CHR Total Percent Asbestos; <1% 0% 0% 0% 1.33%

Other Fibr. Mat. (Type & Percent); 0% 0% 30%FBGL 0% Non Fibr. Mat. (Percent); >99% 100% 100% 70% 98.67% Date Received: 9/5/01 Date of Analysis: 9/6/01 Date of Report: 9/7/01

Analyst; Wi. \)( anJccki Lab Manager: 1 M. Ulanecki David Chen * Analysis of samples is performed by Polarized Light Microscopy (PLM) - Point Counting Method (EPA 600/M4-82-020) * Analytical equipments: Stereobinocular microscope (MEIJI EMT-Serial # 25930), Polarized Light Microscope (MEIJI ML-POL-Serial # 88034) * PLM is not consistently reliable in detecting asbestos in floor coverings and similar non-friable organically bound materials. Quantitative transmission electron microscopy is currently the only method that can be used to determine if this material can be considered or treated as non-asbestos-containing * Samples will be stored for ninety (90) days and then returned to the client upon request * The results relate only to the items calibrated or tested. * The certificate of report shall not be reproduced without the written approval of the laboratory. * The report must not be used by the client to claim endorsement by NVLAP or any agency of the US Government. NYS-DOH ELAP if 11273 NIST-yyLAP # 102047 AIHA if: 100269

17

CITY_21MC100_0 06262478

NYC-WTC_000268249

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000268249Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

No available related records indexed in this group.

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Buildings in this record

Machine-extracted building matches; verify each source. Buildings, never households.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Compare copies and versions →