KAMCONSUUAMTS 35-« 36th Street Long Island City NewYork. 11106 Tel: (718)729-1997 Fax:(718)729-1876

BULK SAMPLE ANALYSIS REPORT CLIENT: NYC-DCAS BUILDING ADDRESS: 14-22 Reade Street, Manhattan PROJECT#: Client Sample ID# :34A 34B 34C 35A 35B Lab Sample ID# : 010905B-235 C10905B-236 010905B-237 010905B-238 010905B-239 Sample Location: RoofC" Roof "C" RacfC" RoofC" RoofC"

Homogeneity; Yes Yes Yes Yes Yes Sample Description Roof Membrane Roof Membrane Roof Membrane Roof Membrane Roof Membrane 1 st Laver 2nd Layer 3td Layer 1st Layer 2nd Layer

Color; Blk Blue Blk Blk Blue Texture: Non Fibrous Non Fibrous Mixed Non Fibrous Non Fibrous Sample Treatment: Acid Digestion Acid Digestion Acid Digestion Acid Digestion Acid Digestion & Ashing & Ashing & Ashing & Ashing & Ashing Asbestos Present: (Type & Percent) ND ND ND ND ND Total Percent Asbestos: 0% 0% 0% 0% 0% Other Fibr. Mat. (Type & Percent): 0% 0% 3()%FBGL 0% 0% Non Fibr. Mat. (Percent): 100% 100% 70% 100% 100% Date Received; 9/5/01 Date of Analysis; 9/6/01 Date of Report: 9/7/01

Analyst: Ya ' 1J 7kY\~ie cK t M. Ulanecki Lab Mana; David Chen * Analysis of samples is performed bv Polarized Light Microscopy (PLM) - Point Counting Method Q (EPA 600/M4-82-020) ♦ Analytical equipments: Stereobinocular microscope (MEIJI EMT-Serial # 25930), Polarized Light Microscope (MEIJI ML-POL-Serial # 88034) * PLM is not consistently reliable in detecting asbestos in floor coverings and similar non-friable organically bound materials. Quantitative transmission electron microscopy is currently the only method that can be used to determine if this material can be considered or treated as r on-asbestos-containing * Samples will be stored for ninety (90) days and then returned to the client upon request * The results relate only to the items calibrated or tested. * The certificate of report shall not be reproduced without the v/ritten approval of the laboratory. * The report must not be used by the client to claim endorsement bv NVLAP or any agency of the US Government. NYS-DOH ELAP# 11273 MST-yyiAP # 102047 AIHA #: 100269

16

CITY_21MC100_0 06262477

NYC-WTC_000268248

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000268248Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

No available related records indexed in this group.

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Buildings in this record

Machine-extracted building matches; verify each source. Buildings, never households.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Compare copies and versions →