NYC Law Department release
Independent mirror · updated as the City releases more · v1.5.1
☕ Buy me a coffee
← Document results/Unboxed/No folder label
Document / 1 page

Bulk sample analysis report, 14-22 DCAS

Machine-extracted title · confidence 25%

Bulk sample IDs and roof locations for DCAS 14-22 address.

NYC-WTC_000386157
Page image
Page image not rendered yet.
The pipeline renders page images incrementally; check back or read the OCR text alongside.
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document

KAMCONSUUANTS 35-40 36th Street Long Island City NewYork,11106 Tel:(718)729-W Fax: 718)729-1875

BULK SAMPLE ANALYSIS REPORT CLIENT: NYC-DCAS BUILDING ADDRESS: 14-22 Reade Street, Manhattan PROJECT#: Client Sample ID# 25B 26A 26B 27A 27B Lab Sample 1Df» 010905B-215 010905B-216 010905B-217 010905B-218 010905B-219 Sample Location Roof "A" Root "A" Roof"A" Roof "A" Roof"A"

Homogeneity Yes Yes Yes Yes Yes Sample Description Base Flashing Base Flashing Base Flashing Base Flashing Base Flashing 2nd Laver 1st La\ei 2nd Laver Ist Laver 2nd Laver

Color Blk Blk Blk Blk Blk Texture Mixed Mixed Mixed Mixed Mixed Sample Treatment Acid Digestion Acid Digestion ■Acid Digestion Acid Digestion Acid Digestion & Ashing & Ashing & Ashing & Ashing & Ashing Asbestos Present- (Type & Percent) 1 23%CHR 2 0%CHR 1 42%CHR 19%CHR 1 5%CHR Total Percent Asbestos: 1.23% 2% 1.42% 1.9% 1.5% Other Fibr. Mat (Type & Percent)- 0% 0% 0% 0% 0% Non Fibr. Mat. (Percent): 98.77% 98% 98 58% 98 1% 98.5% Date Received- 9/5/01 Date of Analysis 9/6/01 Date of Report; 9/7/01 Analyst: VV\ . l /l /XTAil-ckt Lab Mana; M. Ulanecki David Chen * Analysis of samples is performed by Polarized Light Microscopy (PLM) - Point Counting Method (EPA 600/M4-82-020) * Analytical equipments: Stereobinocular microscope (MEIJI EMT-Serial # 25930), Polarized Light Microscope (MEIJI ML-POL-Serial # 88034) * PLM is not consistently reliable in detecting asbestos in floor coverings and similar non-friable organically bound materials. Quantitative transmission electron microscopy is currently the only method that can be used to determine if this material can be considered or treated as non-asbestos-containing * Samples will be stored for ninety (90) days and then returned to the client upon request * The results relate only to the items calibrated or tested ♦ The certificate of report shall not be reproduced without the written approval of the laboratory. * The report must not be used by the client to claim endorsement by NVLAP or any agency of the US Government. NYS-DOH ELAP #11273 NIST-NYLAP # 102047 AIHA#: 100269

12

NYC-WTC_000386157

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000386157Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

No available related records indexed in this group.

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Page similarity is temporarily unavailable or this page has no indexed vector.

Buildings in this record

Machine-extracted building matches; verify each source. Buildings, never households.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Compare copies and versions →