NYC Law Department release
Independent mirror · updated as the City releases more · v1.5.1
☕ Buy me a coffee
← Document results/Unboxed/No folder label
Document / 2 pages

Report of air sampling, Rector Street sites

Machine-extracted title · confidence 42%

September 2001 ambient air sampling report for Rector Street sites by Hygienetics.

NYC-WTC_000386083–000386084
Page image
Page image not rendered yet.
The pipeline renders page images incrementally; check back or read the OCR text alongside.
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document * 5, _ _ ___ SrELLPR TONPGEr’ENT 3308848 NO.268 584

Hygienetics® Environmental Hygicneae* Cnvirenm»..iiai Servieet, 1 West 349^ Sueei Phoni: (313) 244.34e3 7tr, Facr rax; (212) 244-8305 September 26.2001 NtwMxk, (W 1(X»O1

Mr. Victor Purpura Building Manager Stellar Management Two Rector Street New York, NY 10006

Be; Report of Air Sampling Rest! Ite Two Rector Street -Floors 4-8, IS, )6,18-33 and 37

Dear Mr. Purpura;

As requested, Hygienctics Envircninenu) Services, he (Hygiersucs) conducted ambient air ! sampling at the captioned areas. This air sampling was conducted on September 15-21,2001. I Air monitoring was performed by setting up a sampling train at each sampling location Each train consisted of a high volume air sampling pump, which was calibrated to collect air in accordance with the appropriate sampling methodology (NIOSH 7400 Method for airborne fibers), attached to 0 45 Tniciomcterpore size, 25 millimeter diameter mixed cellulose ester membrane filter cassettes with rygon tubing. Open faced cassettes were utilized for the air aamphng. Area air samples were collected at representative interior spaces on each of the referenced floors at Two Rector Street. In addition, field blank samples were also submitted to ths analytical laboratory, for quality controVquality assurance (QA/QC) purposes. A total of 74 samples were submitted for analysis by Scientific Laboratches. Inc. a New York State Department of Hcaltlt (ELAP) Approved laboratory.

On-site pump calibratioo was performed with a high-flow rowmeter. at the start and completion of each sample collection penod, to ensure an accurate volumetric reading The rotameter’s calibration was confirmed prior to its use on-sne, utilizing a Mini Buck Model M-30 bubble calibrator, a primaiy calibration standard. Samoie Data and Discusaon Opucal Phase CtsnirasJ Micrasiope Analysis: Please refer to copies of the attached analytical laboratory's report for the results of the sampling conducted. In summary, toe levels of measured airborne fibers present during the sampling period were relatively low, and did not approach or exceed any applicable, enforceable industrial exposure limits as set by governmental agencies

At the present time, there arc no nan-mdustri?! indoor ait quality standards, or permissible exposure limita for airborne asbestos However, s generaily accepted aiTbnme fiber concentration for “Clean Air” subsequent to asbestos abatement activities in commercial buildings in New York City is 0.01

CITY_21MC100_008870457 NYC-WT C_000386083

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000386083Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Compare copies and versions →