NYC-WTC_000385990
Ambient air sampling conducted at Rector Street locations 4-8, 13-21 September 2001.
2 shared non-person entities · 1 shared topics · similarity 0.990
machine-extracted · confidence unavailable · Check page ↗September 2001 ambient air sampling report for Rector Street sites by Hygienetics.
NYC-WTC_000386083–000386084OCR status: ok · source: pdftotext
NYC 9/11 Public Portal Document ii
___ rflNR^r-ENT ■> 3808840 NCI. 256 pes
Mr. Victor Purpura September 26,2001 Page 2 I
fibers per cubic centimeter (fee). This 0.01 fZee concentration is also referred to as a “Rcoccupancy Criteria" by the NYC Department of Environmental Protection. While the PCM analytical data generated al Two Rector Street was not obtained for the purpose of determining clean air following asbestos activities, the raw analytical results indicate the majorly (> 95%) of measured airborne fiber corcentrstiona to be below this commonly accepted criteria value. Sample results ranged from < 0.003 fZee to 0.013 Pec. All but four of the air samples collected al Two Rector Street were found co e.^hibil fiber concentrations below 0.01 free. With regards to sampling analysis, optical Phase Contrast Microscopy (PCM) is a standard analytical method to assess airborne fiber concentration. Thia method does not distinguish between asbestos and noD'asbestos fiber types, and only those fibers wider than 0,25 micrometers, greater than 5 micrometers in length, and with a length-to-width (aspect) ratio equal to or greater than 3’ 1 were counted. Because of titcsc limitations, fiber counts by PCM typically provide an "index” of the total concentration of psrtieulaies in the ambieni air of an occupied building.
TYanjintission Electron Microscope Re-anafysis: The afotemeotioned four (4) air samples exhibiting elevated (> 0.0 J free) PCM results were rc- aaalyzed by Scientific Laboratories using Transmission Election M.croscopy (TEM) This form of analysis, coupled with sclec»d area electron diffraction (SaED) and x-ray energy disperaive spectroscopy (EDS), enables a fiber’s cbcmicai composition to be identified, thereby overcoming the aforementioned noii-speciflcity of PCM analysis, allowing a definitive determination of whether foe material is asbestos or not. The laboratory results revealed no asbestos etnictures were detected tn any of the four air samples collected at Two Rector Street that exhibited elevated “wial” airborne fiber concentrauons via PCM analysis. Copies of the analytical data are attached for yoi^r reference. If you have any questions or commenu regarding the informatior. presented herein, please feel free to contact Hygienetics at (212) 244 • 3443. Very ^ly yours,
Laurence M. Jaret Project Director
(attachment)
2060,335
CITY_21MC100_008870458 NYC-WT C_000386084
OCR can misread numbers and units. Confirm readings against the page image before using them.
Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.
NYC-WTC_000385990
Ambient air sampling conducted at Rector Street locations 4-8, 13-21 September 2001.
2 shared non-person entities · 1 shared topics · similarity 0.990
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000268390
Ambient air sampling report for Rector Street floors; 9/13-21/2001, with method details.
1 shared non-person entities · 1 shared topics · similarity 0.988
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000268384
Hygienetics air sampling across multiple floors; September 13-21, 2001.
1 shared non-person entities · 1 shared topics · similarity 0.985
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000268513
Hygienes Environmental Services report of ambient air sampling at captioned locations.
2 shared non-person entities · 1 shared topics · similarity 0.980
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000363690
Hygienetics conducted ambient air sampling in multiple Rector Street floors, Sept 19–21, 2001.
4 shared non-person entities · 1 shared topics · similarity 0.983
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000113977
Laboratory report from Hygienetics detailing ambient air sampling results for airborne fibers at 2 Rector Street.
4 shared non-person entities · 1 shared topics · similarity 0.977
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000306376
Ambient air sampling report for 170 Broadway after cleaning; includes methodology.
2 shared non-person entities · 1 shared topics · similarity 0.970
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000121065
Summary of air and dust sampling results collected from private residences and common areas at 250 South End Avenue.
3 shared non-person entities · 1 shared topics · similarity 0.955
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000420968
Permit-related correspondence regarding exterior facade cleaning and condo unit considerations.
3 shared non-person entities · 1 shared topics · similarity 0.945
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000230980
Application submitted to the DEP regarding cleaning procedures for a residential condominium, including exterior facade and interior duct work.
3 shared non-person entities · similarity 0.945
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000409194
Chain-of-custody documenting asbestos sampling and air monitoring at Building 500.
3 shared non-person entities · 1 shared topics · similarity 0.944
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000409163
Chain-of-custody for asbestos visual, bulk and air sampling at Building 500.
3 shared non-person entities · 1 shared topics · similarity 0.943
machine-extracted · confidence unavailable · Check page ↗Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.
NYC-WTC_000385990
Ambient air sampling conducted at Rector Street locations 4-8, 13-21 September 2001.
Similarity score 0.993 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000363690
Hygienetics conducted ambient air sampling in multiple Rector Street floors, Sept 19–21, 2001.
Similarity score 0.990 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000113977
Laboratory report from Hygienetics detailing ambient air sampling results for airborne fibers at 2 Rector Street.
Similarity score 0.990 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000268390
Ambient air sampling report for Rector Street floors; 9/13-21/2001, with method details.
Similarity score 0.989 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000268384
Hygienetics air sampling across multiple floors; September 13-21, 2001.
Similarity score 0.987 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000268513
Hygienes Environmental Services report of ambient air sampling at captioned locations.
Similarity score 0.985 (not a probability)
machine-extracted · confidence unavailable · Check page ↗Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.
NYC-WTC_000385990
Ambient air sampling conducted at Rector Street locations 4-8, 13-21 September 2001.
Similar indexed content
NYC-WTC_000268390
Ambient air sampling report for Rector Street floors; 9/13-21/2001, with method details.
Similar indexed content
NYC-WTC_000268384
Hygienetics air sampling across multiple floors; September 13-21, 2001.
Similar indexed content
NYC-WTC_000363690
Hygienetics conducted ambient air sampling in multiple Rector Street floors, Sept 19–21, 2001.
Similar indexed content
NYC-WTC_000268513
Hygienes Environmental Services report of ambient air sampling at captioned locations.
Similar indexed content