Hygienetics: Sept 2001 air sampling report

Machine-extracted title · confidence 34%

Ambient air sampling report for Rector Street floors; 9/13-21/2001, with method details.

NYC-WTC_000268390–000268391
Page image
Page image not rendered yet.
The pipeline renders page images incrementally; check back or read the OCR text alongside.
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document

r-PNPGErENT 3828840 N0.25&

Mr, Victor Purpura Scpiember 26, 200! Page 2

fibers per cubic centimeter (fee) This 0 01 r7cc concentrarion is also referred to as a “Reoccupancy Criteria” by the NYC Departmeni of Environmental Protection.

While the PCM analytical data generated al Two Rector Sircei was not obtained for the puipose of deiermwing clean air following asbestos activities, rhe raw analylieal results indicate the maiorty (> 95%) of measured airborne fiber concentrations to be below this commonly accepted criteria value. Sample results ranged from < 0.003 free to 0.013 free All but four of the air samples collected al Two Rector Street were found to e.xhipit fiber concentrations below 0.01 free.

With regards to sampling analysis, optical Phase Contras: M’croscopy (PCM) is a standard analytical msthcd to assess airtionie ftbet corccntraticn. This rcsthod does not distinguish between asbestos and non-asbestos fiber types, and only those fibers wider th.an 0,25 nncraineters, greater than 5 micro,meters in length, and with a lenglh-to-widlh (aspect) ratio equal to or greater than 3-1 were counted. Because of diesc limitations, fiber counts by PCM typically provide an "index” of the total concentration of particulates in the ambient su of an occupied building.

Transmission Electron Microscope Hs-anaiysis- The aforementioned four (4) air samples exhibiting elevated (> 0.01 fee) PCM results were tc- acalyzed by Scientific I.3boratone6 using Transnuss'on Eiecuon M-croscopy (TEM). This form of analysts, coupled with selected area electron diffraction (SAED) and x-rsy energy dispersive spectroscopy (EIJS), enables a fiber's chemical coraporitioo to be identifed, thereby overcoming the aforemennoned non-spccificity of PCM analysis, allowing a definitive determination of whether lite matene! is asbestos or not.

The laboratory results revealed no asbestos etructures were detsetsd in any of the four air samples collected at Two Rector Street that exhibited elevated "10131" airbome fiber cancentrahoni via PCM analysis. Copies of the analytical data are atisched foryotir reference

If you have any questions or conimsnu tegarding the infoimatior. presented herein, please feel free ta contact Hygienetics at (212) 2M - 3443.

Very tmly yours,

Laurence M. Jaret Project Director

(anachnenr)

2060.335

CITY_21MC100_006263410 NYC-WTC_000268391

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000268391Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Compare copies and versions →