Re-occupancy recommendations for 170 Broadway, Sep 2001

Machine-extracted title · confidence 95%

A letter from Hygienetics to a building manager providing operational recommendations for reopening 170 Broadway in September 2001.

NYC-WTC_000105738–000105758

Folder label: “170 BROADWAY; Block: 64 Lot: 16 BIN: 1001088 24 Maiden Lane

Page image
Scanned page image, NYC-WTC_000105740
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document FEB-25-2002 18:04 HYGIENETICS NYC 212 244 8505 P.08/21

N gg~leneticsw nyironmental Hygienetics Environinental Servie s, Inc. I West 34th Street Phone: (212) 244-3443 7th Floor Fax- (212) 244-8505 Ncw York, NY 10001

September 27, 2001

Ms. Peggy Nash Building Manager Jones Lang LaSalle Management 170 Broadway Now York, NY 10038

Re: Report of Ambient Air Sampling Results 170 Broadway, New York, NY -

Dear Ms. Nash:

Hygienetics Environmental Services, Inc. (Hygienetics) conducted ambient air sampling throughout the tenant spaces and common areas at the above-captioned facility. This air sampling was conducted subsequent to the interior spaces undergoing environmental cleaning by Pinnacle Environmental Corp. during the period September 19 - 23, 2001.

Pinnacle utilized NYC and NYS Certified asbestos handlers to perform all aspects of the environmental cleaning that was executed at 170 Broadway. Work procedures included the use of HEPA vacuums, and wet wiping techniques.

Air monitoring was performed by setting up a sampling train at each sampling location. Each train consisted of a high volume air sampling pump, which was calibrated to collect air in accordance with the appropriate sampling methodology (NIOSH 740() Method for airborne fibers), attached to 0.45 micrometer pore size, 25 millimeter diameter mixed cellulose ester membrane filter cassettes with tygon tubing. Open faced cassettes were utilized for the air sampling.

Area air samples were collected at representative interior spaces on each of the floors at 170 Broadway. In addition, field blank samples were also submitted to the analytical laboratory, for quality control/quality assurance (QA/QC) purposes. All air samples were submitted for analysis by 5rientiflc Laboratories, Inc. a New York State Department of Health (FLAP) Approved laboratory.

On-site pump calibration was performed with a high-flow rotameter, at the start and completion of each sample collection period, to ensure an accurate volumetric reading_ The rotameter's calibration was confirmed prior to its use on-site, utilizing a Mini Buck Model M-30 bubble calibrator, a primary calibration standard.

NYC-WTC 000105740

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000105740Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Page similarity is temporarily unavailable or this page has no indexed vector.

Buildings in this record

Machine-extracted building matches; verify each source. Buildings, never households.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Compare copies and versions →