Microscopy (PCM) fiber results, 22 River Terrace, 2001

Machine-extracted title · confidence 46%

PCM fiber results report with fiber counts and sample data for 22 River Terrace, 2001.

NYC-WTC_000367163–000367166
Page image
Page image not rendered yet.
The pipeline renders page images incrementally; check back or read the OCR text alongside.
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document

SciLabJob#: 201092829 Page 4 of 4 Client Name: GCI Environmental Advisory, Inc. Phase Contrast Microscopy (PCM) Fiber Results NOl-B-4086; Rockrose Development Corp.; 22 River Terrace, New York, NY, Flow Air Fiber Fibers SciLab Client Date Rate Duration Filtered Density Cone. Fields Fibers TWA Sample # Sample # / Location Collected (Hters/min.) (min.) (liters) (Fibers/mm^ ) (Fibers/cc)

46 22- 9/23- 46 9/23/2001 15 65 975 100 7 8.92 0.004 Apt. 4G, Room- Kitchen / CAS 47 22- 9/23- 47 9/23/2001 15 65 975 100 14 17 83 0.007 Apt. 4P, Room Kitchen / CAS 48 22- 9/23- 48 9/23/2001 15 65 975 100 5 6.37 <0.003 Apt 4J, Room. Kitchen / CAS 49 22- 9/23- 49 9/23/2001 15 65 975 100 8 10.19 0.004 Apt 4Q, Room- Kitchen / CAS 50 22- 9/23- 50 9/23/2001 15 64 960 100 4 5.10 <0.003 Apt. 4D, Room Kitchen / CAS Reporting Notes: (1) Fibers/cc cannot be Mlculatexj for samples (or blanks) with no air volume. Analyzed by Victor Slopac . Date Analyzed 9/23/2001

Samples analyzed by NIOSIl 7400(A) Method, Issue #2. 8/15/94, Limit of Decteclion= 5 5 fibers per 100 fields or 7 fibers/mm2. This report relates ONLY to the sample analysis expressed as fibers/sq mm of filter area, ND = no fibers observed, NA = not analyzed, Walton-Beckett gradicule field area 0 00785 mm2. TWA =8 Hr TWA calculation assumes zero exposure for remainder of 8 hr penod not sampled, Upper 95% Confidence limit (Employers Compliance Test)- Calculated as a one sided UCL to determine 95% certainly of compluncc with the 0 01 filier/cc standard. Estimated relative standard deviation Intralab Sr=O 405, Intcriab Sr=O 45, New York samples (NYSDOH ELAP Lab # 11480), National Institute of Standards and Technology ..tl

o K I NJ

S o o I o o NJ CO cn CO o o

NYC-WTC_000367166

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000367166Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Buildings in this record

Machine-extracted building matches; verify each source. Buildings, never households.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Compare copies and versions →