NYC-WTC_000367169
PCM fiber results report with sample data for 22 River Terrace, 2001.
5 shared non-person entities · 1 shared topics · similarity 0.993
machine-extracted · confidence unavailable · Check page ↗PCM fiber results report with fiber counts and sample data for 22 River Terrace, 2001.
NYC-WTC_000367163–000367166OCR status: ok · source: pdftotext
NYC 9/11 Public Portal Document
SciLabJob#: 201092829 Page 4 of 4 Client Name: GCI Environmental Advisory, Inc. Phase Contrast Microscopy (PCM) Fiber Results NOl-B-4086; Rockrose Development Corp.; 22 River Terrace, New York, NY, Flow Air Fiber Fibers SciLab Client Date Rate Duration Filtered Density Cone. Fields Fibers TWA Sample # Sample # / Location Collected (Hters/min.) (min.) (liters) (Fibers/mm^ ) (Fibers/cc)
46 22- 9/23- 46 9/23/2001 15 65 975 100 7 8.92 0.004 Apt. 4G, Room- Kitchen / CAS 47 22- 9/23- 47 9/23/2001 15 65 975 100 14 17 83 0.007 Apt. 4P, Room Kitchen / CAS 48 22- 9/23- 48 9/23/2001 15 65 975 100 5 6.37 <0.003 Apt 4J, Room. Kitchen / CAS 49 22- 9/23- 49 9/23/2001 15 65 975 100 8 10.19 0.004 Apt 4Q, Room- Kitchen / CAS 50 22- 9/23- 50 9/23/2001 15 64 960 100 4 5.10 <0.003 Apt. 4D, Room Kitchen / CAS Reporting Notes: (1) Fibers/cc cannot be Mlculatexj for samples (or blanks) with no air volume. Analyzed by Victor Slopac . Date Analyzed 9/23/2001
Samples analyzed by NIOSIl 7400(A) Method, Issue #2. 8/15/94, Limit of Decteclion= 5 5 fibers per 100 fields or 7 fibers/mm2. This report relates ONLY to the sample analysis expressed as fibers/sq mm of filter area, ND = no fibers observed, NA = not analyzed, Walton-Beckett gradicule field area 0 00785 mm2. TWA =8 Hr TWA calculation assumes zero exposure for remainder of 8 hr penod not sampled, Upper 95% Confidence limit (Employers Compliance Test)- Calculated as a one sided UCL to determine 95% certainly of compluncc with the 0 01 filier/cc standard. Estimated relative standard deviation Intralab Sr=O 405, Intcriab Sr=O 45, New York samples (NYSDOH ELAP Lab # 11480), National Institute of Standards and Technology ..tl
o K I NJ
S o o I o o NJ CO cn CO o o
NYC-WTC_000367166
OCR can misread numbers and units. Confirm readings against the page image before using them.
Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.
NYC-WTC_000367169
PCM fiber results report with sample data for 22 River Terrace, 2001.
5 shared non-person entities · 1 shared topics · similarity 0.993
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000367172
PCM fiber results report with sample data for 22 River Terrace, 2001.
5 shared non-person entities · 1 shared topics · similarity 0.992
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000367150
SciLab PCM fiber results for 22 River Terrace, sample 01/22/01 data.
5 shared non-person entities · 1 shared topics · similarity 0.983
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000366982
Template PCM fiber results for 333 Rector Place with measured fibers per mm2 and per cc.
4 shared non-person entities · 1 shared topics · similarity 0.974
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000366984
PCM microscopy fiber results for Apt. OSS and Apt 08R at 333 Rector Place.
2 shared non-person entities · 1 shared topics · similarity 0.974
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000366994
PCM microscopy fiber results; single sample referenced, 333 Rector Place NYC.
4 shared non-person entities · 1 shared topics · similarity 0.963
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000366976
PCM microscopy fiber results for 333 Rector Place samples; fiber concentrations reported.
4 shared non-person entities · 1 shared topics · similarity 0.963
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000366972
PCM microscopy fiber results for 333 Rector Place samples; fiber counts and TWA provided.
2 shared non-person entities · 1 shared topics · similarity 0.961
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000367140
SciLab microscopy PCM fiber results for 22 River Terrace, clearance N01-B4086.
5 shared non-person entities · 1 shared topics · similarity 0.959
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000367153
SciLab PCM fiber results for 22 River Terrace, Rockrose project, 4-page report.
5 shared non-person entities · 1 shared topics · similarity 0.957
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000120885
Detailed laboratory analysis of ambient air samples collected in September 2001 at 22 River Terrace to assess asbestos contamination.
5 shared non-person entities · 1 shared topics · similarity 0.976
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000120604
Laboratory analysis of ambient air samples collected in September 2001 at 333 Rector Street to detect asbestos fibers.
4 shared non-person entities · 1 shared topics · similarity 0.966
machine-extracted · confidence unavailable · Check page ↗Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.
NYC-WTC_000367169
PCM fiber results report with sample data for 22 River Terrace, 2001.
Similarity score 0.995 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000367172
PCM fiber results report with sample data for 22 River Terrace, 2001.
Similarity score 0.994 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000120885
Detailed laboratory analysis of ambient air samples collected in September 2001 at 22 River Terrace to assess asbestos contamination.
Similarity score 0.991 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000120604
Laboratory analysis of ambient air samples collected in September 2001 at 333 Rector Street to detect asbestos fibers.
Similarity score 0.989 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000120885
Detailed laboratory analysis of ambient air samples collected in September 2001 at 22 River Terrace to assess asbestos contamination.
Similarity score 0.989 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000120604
Laboratory analysis of ambient air samples collected in September 2001 at 333 Rector Street to detect asbestos fibers.
Similarity score 0.988 (not a probability)
machine-extracted · confidence unavailable · Check page ↗Machine-extracted building matches; verify each source. Buildings, never households.
Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.
NYC-WTC_000367169
PCM fiber results report with sample data for 22 River Terrace, 2001.
Similar indexed content
NYC-WTC_000367172
PCM fiber results report with sample data for 22 River Terrace, 2001.
Similar indexed content
NYC-WTC_000367150
SciLab PCM fiber results for 22 River Terrace, sample 01/22/01 data.
Similar indexed content
NYC-WTC_000120885
Detailed laboratory analysis of ambient air samples collected in September 2001 at 22 River Terrace to assess asbestos contamination.
Similar indexed content
NYC-WTC_000366982
Template PCM fiber results for 333 Rector Place with measured fibers per mm2 and per cc.
Similar indexed content