NYC Law Department release
Independent mirror · updated as the City releases more · v1.5.1
☕ Buy me a coffee
← Document results/Unboxed/No folder label
Document / 166 pages

Bulk sample report, 100 Church Street site

Machine-extracted title · confidence 55%

Report of bulk sample collection at 100 Church Street for WTC-related work.

NYC-WTC_000364399–000364564
Page image
Page image not rendered yet.
The pipeline renders page images incrementally; check back or read the OCR text alongside.
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document

MINIMUM CONTRACTOR REQUIREMENTS

tape. At each perimeter breach place at least three separate layers of poly so that one layer can be left in place after air clearance monitoring and until the breach can be repaired permanently.

1.5 On each respective floor, select a single location as means of access onto the floor. It will either through the freight elevator corridor or stairwell. Seal all other communicating openings, which lead onto the respective floor. These openings can include but not be limited to all passenger elevator doors, emergency stairwells, shafts, all HVAC supply and return diffusers, etc.

1.6 Isolate any unaffected (non-contaminated) areas from the areas to be work in. After cleanup is successfully completed in each respective area of a floor, isolate area so as avoid possible re-contamination of clean areas.

1.7 All contaminated areas on floors are to be cleaned and released prior to cleanup of any non-contaminated areas. Non-contaminated areas can be cleaned as a non- ACM activity.

1.8 Coordinate with Tenant Representative the decontamination of any employee personal property and tenant office fixtures.

1.3 Perform the work in strict compliance with applicable federal, state, and local regulations, codes, standards and guidelines regarding asbestos abatement except where more stringent requirements are set forth herein. Where conflicting requirements are set forth in the above, the more stringent requirements or guidelines shall apply. Require that all woric be executed by skilled craftsperson experienced in their respective trades.

1.4 The most recently dated issue or set of the following documents shall govern. If any of these documents are revised or updated prior to the final completion of the project, the revised or updated issue shall govern and all work affected by the revision or update shall be modified accordingly.

a) New York State Industrial Code, Rule 56 “Asbestos (12 NYCRR 56) b) New York City Local Law 70 and Title 15, Chapter 1. c) AU other applicable NYS and NYC laws, codes, variances and ordinances. d) USEPA regulations for asbestos abatement projects. Final Rule (CFR 40 Part 763) e) USEPA regulations for Asbestos, CFR 40 Part 61, Subpart M, National Emission Standards for Hazardous Air Pollutants (NESHAPS) f) U.S. Department of Labor, Occupational Safety and Health Administration (OSHA) Asbestos Regulations (CRF 29, Parts 1910 and 1926). g) USEPA Office of Pesticides and Toxic Substance, “Guidance for Controlling Asbestos- Containing Materials in Building", EPA 560/5-85-024, June 1985.

Maintain one copy of each reference standard on site for the duration of the project.

1.5 The Work shall be sequenced as follows:

a) Isolate the work area by establishing a restricted zone around the area. Protect, as necessary. b) Construct applicable remote decontamination system. c) Erect appropriate enclosure in the work area.

REMOVAL OF ACM DUST PAGE 2 ZAE Realty Selected Floors/Areas 100 Church Street

CITY_DEP_WORBY_CANNATA_SUBP_000001842

NYC-WTC_000364402

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000364402Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Buildings in this record

Machine-extracted building matches; verify each source. Buildings, never households.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Compare copies and versions →