Asbestos air sampling at Battery Place, Oct 2001

Machine-extracted title · confidence 32%

Asbestos air sampling report for Battery Place, NIOSH 7400 method, detailed pump specs.

NYC-WTC_000363798
Page image
Scanned page image, NYC-WTC_000363798
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document

01/30/02 15:37 NC.975 CQT

Enviro Techniques, Inc. 22 California Avenue, Paterson, NJ 07503 6 (973)684-0202

October 11, 2001

Mr. Sal Panico Urban Associates, LLC. 400 West 59th Street New York, 10019

Re: Asbestos Air Quality Sampling at: River Watch 70 Battery Place New York, New York 10280

Dear Mr. Sal Panico;

Enviro Techniques, Inc. conducted air quality sampling at the above referenced building.

All samples were collected and analyzed by NIOSH 7400 method using Phase Contrast Microscopy. Airborne asbestos fibers were collected on miilipore type AA mixed cellulose ester fiber filters with a diameter of 25mm and a pore size of 0.8 gm. The filters were housed in three stage plastic cassettes and connected by Tygon tubing to portable air sampling pumps. The top piece of each cassette was removed during sampling, providing the open faced collection called for by the NIOSH method. This provides an even distribution of fibers on to the filters.

Precision portable air sampling pumps were, used for sample collection. The make and models of these high volume pumps are Speedaire 4Z791, Speedaire 4X792, Gast 1531-1070-G288X, Dawson and Allegro equivalents. These pumps operate at flow rates between 5 0 and 16.0 liters per minute. All pumps are calibrated at the beginning and the end of each sampling period using a precision rotometer which is calibrated against a primary standard in our laboratory. Following sampling, the samples were analyzed using Phase Contrast Microscopy. The non analyzed portion of the filter was archived at our laboratory.

The NIOSH 7400 method does not distinguish asbestos fibers from other airborne fibers. The criteria specified in the method for counting fibers are size and length to width ratio. Under this methodology all fibers which meet these criteria are counted to determine the concentration of airborne contaminants. The results achieved by this method represent the concentrations of all airborne fibers above a certain size.

1

CITY_21MC100_002860136 NYC-\/VTC_000363798

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000363798Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Compare copies and versions →