02/08/2002 14:03 FAX 212 353 8306 ATC I2J005

Mr. Bernard P. Orlan February 8, 2002 Indoor Air Quality Assessment Page 4 P. S, 89M________________ ATC Project No. 15-19125-0297 building was approximately 32 jigZin^ (a.M.) and 52 pg/ra^ (P.M.). One (1) A.M. and thirteen (13) P. M. indoor measurements were above the USEPA recommended concentration of 40 pg/m3 for sensitive individuals such as astlunatic people and children. The outdoor respirable particulate concentration averaged 54 p-g/m^ (A.M ) and 99 jig/m^ (P.M.).

* The measurements made during tins assessment were instantaneous readings, the NPAAQS is a 24-hour average.

TVOC CoTicenlration

TVOCs were not detected (0.0 ppm) anywhere inside or outside the building.

OBSERVATIONS

During this assessment, ATC noted the following;

• The interior of tlie building appeared clean and free of dust and debris; • Custodial personnel started buffing the floors after classes finished for the day; • The school was partially occupied (l.S. 89) at the time of the assessment; • No smoke odor was detected in die building.

FINDINGS

Based on tire real-time measurements, the following findings are presented;

1. Concentrations of CO2’ CO and TVOC were within applicable guidelines; 2. Six (6) of tire PM2,5 measurements collected in the afternoon were above the NPAAQS of 65 pg/ni3. One (1) PM2.5 measurement collected in the morning and thirteen (13) collected in the afternoon were above the USEPA recommended PMo.s concentration of 40 pg/m^ for sensitive individuals and children. 3. In the morning, two (2) measurements of temperature were below and six (6) measuremenTs were above the recommended range. In the afternoon, seven (7) measurements of temperature were below the recommended range; 4. Fifteen (15) indoor measurements of relative humidity in tlie afternoon were within tire ASHRA.E reconnnended range of 30 to 60 percent for occupant comfort. All other measurements were below tlie recommended range.

It is our pleasure to provide these indoor air quality services to the New York City Board of Education. If you have any questions about this report, please call (212) 353-8280, extension 261 or 212.

Sincerely, ATCASSOC/ATSS r/VC.

Andreas C. Andreou Senior Project Manager

Attachment

CITY_21MC100_009253155

NYC-WTC_000359855

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000359855Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

No available related records indexed in this group.

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Buildings in this record

Machine-extracted building matches; verify each source. Buildings, never households.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Compare copies and versions →