NYC Law Department release
Independent mirror · updated as the City releases more · v1.5.1
☕ Buy me a coffee
← Document results/Unboxed/No folder label
Document / 4 pages

Indoor air quality, P.S. 89M, Feb 2002

Machine-extracted title · confidence 37%

Indoor air quality measurements collected Feb 7, 2002 at P.S. 89M.

NYC-WTC_000382575–000382578
Page image
Page image not rendered yet.
The pipeline renders page images incrementally; check back or read the OCR text alongside.
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document

Mr. Bernard P. Orlan February 8, 2002 Indoor Air Quality Assessment Page 4 P. S. 89M ATC Project No. 15-19125-0297 building was approximately 32 pg/m^ (A.M.) and 52 pg/m^ (P.M.). One (1) A.M. and thirteen (13) P. M. indoor measurements were above the USEPA recommended concentration of 40 pg/m3 for sensitive individuals such as asthmatic people and children. The outdoor respirable particulate concentration averaged 54 pg/m^ (A.M.) and 99 pg/m^ (P.M.).

* The measurements made during this assessment were instantaneous readings, the NPAAQS is a 24-hour average.

TVOC Concentration

TVOCs were not detected (0.0 ppm) anywhere inside or outside the building.

OBSERVATIONS

During this assessment, ATC noted the following;

• The interior of the building appeared clean and free of dust and debris; • Custodial personnel started buffing the floors after classes finished for the day; • The school was partially occupied (I.S. 89) at the time of the assessment; • No smoke odor was detected in the building.

FINDINGS

Based on the real-time measurements, the following findings are presented:

1. Concentrations of CO2, CO and TVOC were within applicable guidelines; 2. Six (6) of the PM2.5 measurements collected in the afternoon were above the NPAAQS of 65 pg/m3. One (1) PM2.5 measurement collected in the morning and thirteen (13) collected in the afternoon were above the USEPA recommended PM2.5 concentration of 40 pg/nU for sensitive individuals and children. 3. In the morning, two (2) measurements of temperature were below and six (6) measurements were above the recommended range. In the afternoon, seven (7) measurements of temperature were below the recommended range; 4. Fifteen (15) indoor measurements of relative humidity in the afternoon were within the ASHRAE recommended range of 30 to 60 percent for occupant comfort. All other measurements were below the recommended range.

It is our pleasure to provide these indoor air quality services to the New York City Board of Education. If you have any questions about this report, please call (212) 353-8280, extension 261 or212.

Sincerely, A TC ASSOCL4 TES INC.

Andreas C. Andreou Senior Project Manager

Attachment

CITY_21MC100_000466571 NYC-WTC_000382578

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000382578Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

No available related records indexed in this group.

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Buildings in this record

Machine-extracted building matches; verify each source. Buildings, never households.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

IAQ report, P.S.89M, Feb 2002

NYC-WTC_000327374

Indoor air quality report for the NYC Board of Education at PS 89M; measurements taken mid-February.

Similar indexed content

Compare copies and versions →