Mr. Bernard P. Orlan February 8,2002 Indoor Air Quality Assessment Page 4 P. S. 89M t f ATC Project No. 15-19125-0297 building was approximately 32 pg/rn^ (A.M.) and 52 pg/m3 (P.M.). One (1) A.M. and thirteen (13) P. M. indoor measurements were above the USEPA recommended concentration of 40 pg/m^ for sensitive individuals such as asthmatic people and children. The outdoor respirable particulate concentration averaged 54 pg/m3 (A.M.) and 99 pg/m3 (P.M.).

* The measurements made during this assessment were instantaneous readings, the NPAAQS is a 24-hour average.

TVOC^(^nc^i.tration

TVOGs were not detected (0.0 ppm) anywhere inside or outside the building.

OBSERVATIONS

During this assessment, ATC noted the following;

• The interior of the building appeared clean and free of dust and debris; • Custodial personnel started buffing the floors after classes finished for the day; • The school was partially occupied (I.S. 89) at thetime of the assessment; • No smoke odor was detected in the building.

FINDINGS

Based on the real-time measurements, the following findings are presented:

1. Concentrations of COp, CO and TVOC were within applicable guidelines; 2. Six (6) of the PM2.5 measurements collected in the afternoon were above the NPAAQS of 65 pg/m^. One (1) PM2.5 measurement collected in the morning and thirteen (13) collected in the afternoon were above the USEPA recommended PM2.5 concentration of 40 pg/nC for sensitive individuals and children. —i 3. In the moming, two (2) measurements of temperature were below and six (6) measurements were above the recommended range. . In the afternoon, seven (7) measurements of temperature were below the recommended range; 4. Fifteen (15) indoor measurements of relative humidity in the afternoon were within the ASHRAE recommended range of 30 to 60 percent for occupant comfort. All other measurements were below the recommended range.

It is our pleasure to provide these indoor air quality services to the New York City Board of Education. If you have any questions about this report, please call (212) 353-8280, extension 261 or 212. ■

Sincerely, V ATCASSOCL4TES INC.

Andreas C/Andreou Senior Project Manager

Attachment

CITY_21MC100_003270823

NYC-WTC_000327377

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000327377Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

No available related records indexed in this group.

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Buildings in this record

Machine-extracted building matches; verify each source. Buildings, never households.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Compare copies and versions →