FDNY spill at Barclay Street, Sept 2001

Machine-extracted title · confidence 46%

Preliminary report of a potential asbestos and transformer oil release at a substation site.

NYC-WTC_000355951–000355957
Page image
Page image not rendered yet.
The pipeline renders page images incrementally; check back or read the OCR text alongside.
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document

Environmental Detailed Incident Report

Report Type: Preliminary Trade Center Incident ID: 139420 Incident Status: - Pending Safe Access Incident Type: Spill - Dielectric, Transformer Brief Description: TRANSF. ~ BARCLAY ST (TRADE CT SUBSTATION) - POTENTIAL OIL SPILL Administrative Site: Manhattan Substations Responsible Operation: Substation Operations Location: BARCLAY ST (TRADE CT SUBSTATION) No. of Injuries: Any Outside Impact: N NOV Number: Immediate Abatement/Containment Actions: NONE - PENDING SAFE ACCESS DUE TO WTC CONTINGENCY Start (Incident First Discovered): 1 l-SEP-2001 19:26:00 First Reported: II-SEP-2001 19:26:00 First Reported to CIG: I l-SEP-2001 19:45:00 Cleanup Completed/Stopped: Resolved (administrative closure): Duration Hours (discovery to closure):

Detailed Description: 9/11/01 19:50 hrs.

Harry Coates #74415, Section Mgr. E,H&S reported to W. Lee #33243 at 19:26 hrs. the potential release of asbestos and transformer oil to the environment due to the World Trade Center contingency. Mr. Coates was making this report for Substation Operations. The asbestos and transformer oil release was from transformers located in the Trade Center Substation No. 1 & 2 and possibly from network protectors located in distribution transformer vaults. The cause was from fire and equipment damage due to the WTC contingency. It is not known at this time how much asbestos and transformer oil was released.

There was fire involved. It is not known if sewer or waterway was affected. The following private property was affected; buildings, vehicles, property and personal articles. The substance was spilled on concrete, asphalt, bluestone, soil, water, people and unknown at this time. There was oil filled equipment in the structures. Sewer connections cannot be verified at this time. No samples taken at this time. No initial cleanup action taken. Cleanup pending investigation and safe access.

CIG Bill Murphy #76378 notified at 19:45 hrs. Note: This incident was recorded by W. Lee #33243 and logged by R. Pellegrino #38620 o H 1"^ Updated CIG Sean McKeever #15523 at 21:06 hrs. R. Pellegrino #38620 S o o o update 9-12-01 @ 01:40 . H Coates reports that there is fs6 gas in the circuit switchs and the automatic ground switchs, also potential peb's in the oil. 1 CIG S McKeever #15523 notified @ 23:43 { update could not be inputted at time of report due to e2mis system was o o down) .J Moran #01182 co kO fO

fO E2MI3 24-SEP-2001 08:13:23 Page 1 of 7 CO

NYC-WTC_000355951

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000355951Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

No available related records indexed in this group.

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Buildings in this record

Machine-extracted building matches; verify each source. Buildings, never households.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

NYC-WTC_000130438 · Box DEP Box 53

Draft special investigative audit report on environmental data from the World Trade Center site prepared by IT Corporation.

Similar indexed content

Compare copies and versions →