lv

§38.95 49 CFR Subtitle A (10-1-98 Ectlon)

be within plus or minus 2 inches of the or shall provide other appropriate platform height. mechanisms or systems, to ensure that (e) Signage. The International Sym- the car cannot be moved when the lift bol of Accessibility shall be displaced is not stowed and so the lift cannot be on the exterior of all doors complying deployed unless the interlocks or sys. with this section unless all cars are ac- tems are engaged. The lift shall deploy cessible and are not marked by the ac- to all platform levels normally encoun- cess symbol (see Fig. 6). Appropriate tered in the operating environment. signage shall also indicate which acces- Where provided, each control for de- sible doors are adjacent to an acces- ploying, lowering, raising, and stowing sible restroom, if applicable. the lift and lowering the roll-off bar- rier shall be of a monetary contact §38.95 Mobility aid accessibility. type requiring continuous manual pres- (a)(1) General. All new commuter rail sure by the operator and shall not cars, other than level entry cars, cov- allow improper lift sequencing when ered by this subpart shall provide a the lift platform is occupied. The con- level-change mechanism or boarding trols shall allow reversal of the lift op- device (e.g., lift, ramp or bridge plate) eration sequence, such as raising or complying with either paragraph (b) or lowering a platform that is part way (c) of this section; sufficient clearances down, without allowing an occupied to permit a wheelchair or mobility aid platform to fold or retract into the user to reach a seating location; and at stowed position. least two wheelchair or mobility aid (ii) Exception. Where physical or safe- seating locations complying with para- ty constraints prevent the deployment graph (d) of this section. at some stops of a lift having its long (2) Exception. If portable or platform dimension perpendicular to the car lifts, ramps or bridge plates meeting axis, the transportation entity may the applicable requirements of this sec- specify a lift which is designed to de- tion are provided on station platforms ploy with its long dimension parallel to or other stops required to be accessible, the car axis and which pivots into or or mini-high platforms complying with out of the car while occupied (i.e., "ro- §38.93(d) are provided, the car is not re- tary lift"). The requirements of para- quired to be equipped with a car-borne graph (b)(2)(i) of this section prohibit- device. Where each new car is compat- ing the lift from being stowed while oc- ible with a single platform-mounted cupied shall not apply to a lift design access system or device, additional sys- of this type if the stowed position is tems or devices are not required for within the passenger compartment and each car provided that the single de- the lift is intended to be stowed while vice could be used to provide access to occupied. each new car if passengers using wheel- (iii) Exception. The brake or propul- chairs or mobility aids could not be ac- sion system interlock requirement does commodated on a single car. not apply to a platform mounted or (b) Car Lift—(1) Design load. The de- portable lift provided that a mechani- sign load of the lift shall be at least 600 cal, electrical or other system operates pounds. Working parts, such as cables, to ensure that cars do not move when pulleys, and shafts, which can be ex- the lift is in use. pected to wear, and upon which the lift (3) Emergency operation. The lift shall depends for support of the load, shall incorporate an emergency method of have a safety factor of at least six, deploying, lowering to ground or plat- based on the ultimate strength of the form level with a lift occupant, and material. Nonworking parts, such as raising and stowing the empty lift if platform, frame, and attachment hard- the power to the lift fails. No emer- ware which would not be expected to gency method, manual or otherwise, wear, shall have a safety factor of at shall be capable of being operated in a least three, based on the ultimate manner that could be hazardous to the strength of the material. lift occupant or to the operator when (2) Controls—(1) Requirements. The operated according to manufacturer's controls shall be interlocked with the instructions, and shall not permit the car brakes, propulsion system, or door, platform to be stowed or folded when

524

NYC-WTC 000355607

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000355607Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

No available related records indexed in this group.

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Compare copies and versions →