NYC-WTC_000385123
Form containing terrorism-related materials; NYC archives material.
6 shared non-person entities · 1 shared topics · similarity 0.956
machine-extracted · confidence unavailable · Check page ↗Codified records of documents and custody in DOT files.
NYC-WTC_000355074–000355754OCR status: ok · source: pdftotext
NYC 9/11 Public Portal Document
§38.83 49 CFR Subtitle A (10-1-98 Edition)
new vehicle if passengers using wheel- ment and the lift is intended to be chairs or mobility aids could not be ac- stowed while occupied. commodated on a single vehicle. (iii) Exception. The brake or propul- (b) Vehicle lift—(l) Design load. The sion system interlocks requirement design load of the lift shall be at least does not apply to a station platform 600 pounds. Working parts, such as ca- mounted lift provided that a mechani- bles, pulleys, and shafts, which can be cal, electrical or other system operates expected to wear, and upon which the to ensure that vehicles do not move lift depends for support of the load, when the lift is in use. shall have a safety factor of at least (3) Emergency operation. The lift shall six, based on the ultimate strength of incorporate an emergency method of the material. Nonworking parts, such deploying, lowering to ground level as platform, frame, and attachment with a lift occupant, and raising and hardware which would not be expected stowing the empty lift if the power to to wear, shall have a safety factor of at the lift fails. No emergency method, least three, based on the ultimate manual or otherwise, shall be capable strength of the material. of being operated in a manner that (2) Controls—(i) Requirements. The could be hazardous to the lift occupant controls shall be interlocked with the or to the operator when operated ac- cording to manufacturer's instructions, vehicle brakes, propulsion system, or and shall not permit the platform to be door, or shall provide other appropriate stowed or folded when occupied, unless mechanisms or systems, to ensure that the lift is a rotary lift intended to be the vehicle cannot be moved when the stowed while occupied. lift is not stowed and so the lift cannot (4) Power or equipment failure. Lift be deployed unless the interlocks or platforms stowed in a vertical position, systems are engaged. The lift shall de- and deployed platforms when occupied, ploy to all levels (i.e., ground, curb, shall have provisions to prevent their and intermediate positions) normally deploying, falling, or folding any faster encountered in the operating environ- than 12 inches/second or their dropping ment. Where provided, each control for of an occupant in the event of a single deploying, lowering, raising, and stow- failure of any load carrying compo- ing the lift and lowering the roll-off nent. barrier shall be of a momentary con- (5) Platform barriers. The lift platform tact type requiring continuous manual shall be equipped with barriers to pre- pressure by the operator and shall not vent any of the wheels of a wheelchair allow improper lift sequencing when or mobility aid from rolling off the lift the lift platform is occupied. The con- during its operation. A movable barrier trols shall allow reversal of the lift op- or inherent design feature shall pre- eration sequence, such as raising or vent a wheelchair or mobility aid from lowering a platform that is part way rolling off the edge closest to the vehi- down, without allowing an occupied cle until the lift is in its fully raised platform to fold or retract into the position. Each side of the lift platform stowed position. which extends beyond the vehicle in its (ii) Exception. Where physical or safe- raised position shall have a barrier a ty constraints prevent the deployment minimum 11h inches high. Such bar- at some stops of a lift having its long riers shall not Interfere with maneu- dimension perpendicular to the vehicle vering into or out of the aisle. The axis, the transportation entity may loading-edge barrier (outer barrier) specify a lift which is designed to de- which functions as a loading ramp ploy with its long dimension parallel to when the lift is at ground level, shall the vehicle axis and which pivots into be sufficient when raised or closed, or a or out of the vehicle while occupied supplementary system shall be pro- (i.e., "rotary lift"). The requirements vided, to prevent a power wheelchair or of paragraph (b)(2)(i) of this section mobility aid from riding over or defeat- prohibiting the lift from being stowed ing it. The outer barrier on the out- while occupied shall not apply to a lift board of the lift shall automatically design of this type if the stowed posi- rise or close, or a supplementary sys- tion is within the passenger compart- tem shall automatically engage, and
520
NYC-WTC 000355603
OCR can misread numbers and units. Confirm readings against the page image before using them.
Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.
No available related records indexed in this group.
NYC-WTC_000385123
Form containing terrorism-related materials; NYC archives material.
6 shared non-person entities · 1 shared topics · similarity 0.956
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000153563
Document page from DEP Box 26 regarding World Trade Center Air Quadrant D with illegible text content.
4 shared non-person entities · 1 shared topics · similarity 0.940
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000115338
License agreement between the City of New York and a landowner for removing foreign material from building exteriors at 211 Pearl Street.
4 shared non-person entities · 1 shared topics · similarity 0.934
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000165271
Engineering drawings and specifications for replacing a high-pressure water line under the Lincoln Tunnel contract.
1 shared non-person entities · 1 shared topics · similarity 0.934
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000115561
Attorney letter regarding legal proceedings between environmental protection authorities and property owners at 29 Park Row.
5 shared non-person entities · 1 shared topics · similarity 0.933
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000118384
Agreement between the City of New York and 60 Broad Street LLC for removing foreign material from building exteriors.
6 shared non-person entities · 1 shared topics · similarity 0.932
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000102407
Header page of legal correspondence from counsel regarding environmental remediation at 83 Maiden Lane in October 2002.
6 shared non-person entities · 1 shared topics · similarity 0.932
machine-extracted · confidence unavailable · Check page ↗5 shared non-person entities · 1 shared topics · similarity 0.930
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000112508
A license agreement between the City of New York and a landowner to remove foreign material from building exteriors near the World Trade Center site.
7 shared non-person entities · 1 shared topics · similarity 0.930
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000118972
Facility inspection form documenting ACM and air monitoring status for a building at 65 Beaver Street.
6 shared non-person entities · 1 shared topics · similarity 0.930
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000118359
Agreement between the City of New York and 60 Broad Street LLC for removing foreign material from building exteriors.
6 shared non-person entities · 1 shared topics · similarity 0.930
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000127520
Official notice urging building owners to participate in the DEP program for cleaning World Trade Center debris from exterior surfaces.
6 shared non-person entities · 1 shared topics · similarity 0.929
machine-extracted · confidence unavailable · Check page ↗Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.
NYC-WTC_000125098
Protocol document outlining air sampling and monitoring procedures for 130 Cedar Street.
Similarity score 0.912 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000164671
Draft document titled World Trade Center Emergency Safety and Health Plan dated September 30, 2001.
Similarity score 0.911 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000145027
Notice from NYC Law Department instructing staff to preserve World Trade Center documents for potential legal actions.
Similarity score 0.909 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000279102
Building Department memo/guide related to emergency planning after 9/11.
Similarity score 0.908 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000145027
Notice from NYC Law Department instructing staff to preserve World Trade Center documents for potential legal actions.
Similarity score 0.906 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000145027
Notice from NYC Law Department instructing staff to preserve World Trade Center documents for potential legal actions.
Similarity score 0.902 (not a probability)
machine-extracted · confidence unavailable · Check page ↗Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.
NYC-WTC_000385123
Form containing terrorism-related materials; NYC archives material.
Similar indexed content
Document page from DEP Box 26 regarding World Trade Center Air Quadrant D with illegible text content.
Similar indexed content
NYC-WTC_000115338
License agreement between the City of New York and a landowner for removing foreign material from building exteriors at 211 Pearl Street.
Similar indexed content
NYC-WTC_000165271
Engineering drawings and specifications for replacing a high-pressure water line under the Lincoln Tunnel contract.
Similar indexed content
Attorney letter regarding legal proceedings between environmental protection authorities and property owners at 29 Park Row.
Similar indexed content