NYC Law Department release
Independent mirror · updated as the City releases more · v1.5.1
☕ Buy me a coffee
← Document results/Unboxed/No folder label
Document / 681 pages

Chain of custody log, DOT materials, 1998

Machine-extracted title · confidence 52%

Codified records of documents and custody in DOT files.

NYC-WTC_000355074–000355754
Page image
Page image not rendered yet.
The pipeline renders page images incrementally; check back or read the OCR text alongside.
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document

Office of the Secretary of Transportation §38.83 remain raised, closed, or engaged at all (10) Platform movement. No part of the times that the lift is more than 3 platform shall move at a rate exceed- inches above the station platform or ing 6 inches/second during lowering and roadway and the lift is occupied. Alter- lifting an occupant, and shall not ex- natively, a barrier or system may be ceed 12 inches/second during deploying raised, lowered, opened, closed, en- or stowing. This requirement does not gaged or disengaged by the lift opera- apply to the deployment or stowage cy- tor provided an interlock or inherent cles of lifts that are manually deployed design feature prevents the lift from or stowed. The maximum platform hor- rising unless the barrier is raised or izontal and vertical acceleration when closed or the supplementary system is occupied shall be 0.3g. engaged. (11) Boarding direction. The lift shall (6) Platform surface. The lift platform permit both inboard and outboard fac- surface shall be free of any protrusions ing of wheelchairs and mobility aids. over i/a inch high and shall be slip re- (12) Use by standees. Lifts shall ac- sistant. The lift platform shall have a commodate persons using walkers, minimum clear width of 28% inches at crutches, canes or braces or who other- wise have difficulty using steps. The the platform, a minimum clear width lift may be marked to indicate a pre- of 30 inches measured from 2 inches ferred standing position. above the lift platform surface to 30 (13) Handrails. Platforms on lifts inches above the surface, and a mini- shall be equipped with handrails, on mum clear length of 48 inches meas- two sides, which move in tandem with ured from 2 inches above the surface of the lift which shall be graspable and the platform to 30 inches above the sur- provide support to standees throughout face. (See Fig. 1) the entire lift operation. Handrails (7) Platform gaps. Any openings be- shall have a usable component at least tween the lift platform surface and the 8 inches long with the lowest portion a raised barriers shall not exceed % inch minimum 30 inches above the platform wide. When the lift is at vehicle floor and the highest portion a maximum 38 height with the inner barrier (if appli- inches above the platform. The hand- cable) down or retracted, gaps between rails shall be capable of withstanding a the forward lift platform edge and ve- force of 100 pounds concentrated at any hicle floor shall not exceed V inch point on the handrail without perma- horizontally and % inch vertically. nent deformation of the rail or its sup- Platforms on semi-automatic lifts may porting structure. Handrails shall have have a hand hold not exceeding 1V a cross-sectional diameter between 13 inches by 4Va inches located between inches and 1½ inches or shall provide the edge barriers. an equivalent grasping surface, and (8) Platform entrance ramp. The en- have eased edges with corner radii of trance ramp, or loading-edge barrier not less than % inch. Handrails shall be used as a ramp, shall not exceed a slope placed to provide a minimum 1% inches of 1:8 measured on level ground, for a knuckle clearance from the nearest ad- maximum rise of 3 inches, and the jacent surface. Handrails shall not transition from the station platform or interfere with wheelchair or mobility roadway to ramp may be vertical with- aid maneuverability when entering or out edge treatment up to ¼ inch. leaving the vehicle. Thresholds between ¼ inch and ½ inch (c) Vehicle ramp or bridge plate.—(1) high shall be beveled with a slope no Design load. Ramps or bridge plates 30 greater than 1:2. inches or longer shall support a load of (9) Platform deflection. The lift plat- 600 pounds, placed at the centroid of form (not including the entrance ramp) the ramp or bridge plate distributed shall not deflect more than 3 degrees over an area of 26 inches, with a safety (exclusive of vehicle roll) in any direc- factor of at least 3 based on the ulti- tion between its unloaded position and mate strength of the material. Ramps its position when loaded with 600 or bridge plates shorter than 30 inches pounds applied through a 26 inch by 26 shall support a load of 300 pounds. inch test pallet at the centroid of the (2) Ramp surface. The ramp or bridge lift platform. plate surface shall be continuous and

521

NYC-WTC 000355604

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000355604Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

No available related records indexed in this group.

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Compare copies and versions →