Dioxin sampling table, Sept–Oct 2001

Machine-extracted title · confidence 53%

Dioxin results across sites; some locations above EPA guidelines but generally below critical levels.

NYC-WTC_000354397
Page image
Page image not rendered yet.
The pipeline renders page images incrementally; check back or read the OCR text alongside.
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document

CCT-12-2001 16:04 71S 732 452 6464 710 732 452 6464 P.03/25

Ambient Air Sampling; Locations NYC / ER (Sept 27) - Dioxin o No occupational standards available. o 2 of the 10 samples collected were above the EPA Removal Action guidelines (based on a 30-year exposure). o 1 of the 10 samples (Location A - West Broadway/Barclay) was nominally above the EPA Removal Action level guidelines adjusted to a l-year exposure duration. o Levels do not pose a short-term health concern. However, elevated sufficiently to be of concern for long-term (chronic exposure). o Other than Location A, overall levels were generally lower than the previously reported round of dioxin sampling (Sep 23). o All current results are below the dioxin levels noted at the 4 locations (Locations B, C, D, and F) sampled during the initial round of dioxin sampling (Sep 16). 0 iNVC / ER (Oct 9) - Particulate Monitoring (PMj j) o Pace University (Site 1) - 24-hr average concentration for this period was 15,84 ug/mL o Manhattan Boro Community College (Site 2) - 24-hour average concentration for this period was 13.70 ug/m^ o Coast Guard Building - Battery Park (Site 3) - 24-hour average concentrations for this period was 10.36 ug/m-* o All readings below the National Ambient Air Quality Standard for PMjj (65 ug/m^).

NYC / ER (Oct 10) - Particulate Monitoring (PM^J O Face University (Sits 1) - 24-hr average concentration for this period was 18.04 ug/mL o Manliattan Boro Community College (Site 2) - 24-hour average concentration for this period was 17.77 ug/m\ o Coast Guard Building - Battery Park (Site 3) - 24-hour average concentrations for this period was 12.36 ug/m\ ~ o All readings below the National Ambient Air Quality Standard for PM, , (65 ug/mQ. NYC / ER (Oct 11) - Particulate Monitoring (Dataram) o Levels noted at three locations (Stations L, M, and N) were well below the OSHA TV/A (respirable) for particulates.

NYC / ER (Oct 11) - Volatile organics (TAGA) o General increase in overall volatile organic levels (including benzene) noted in plume samples collected in debris arsa as compared to yesterday’s data. o Benzene exceeded OSHA TWA PEL at two locations on the debris pile in the plume at ground level.

Direct Reading Instruments NYC / ER (Oct 11) o Nothing of significance reported.

CITY_21MC100_008111808

NYC-WTC_000354397

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000354397Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

No available related records indexed in this group.

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

NYC-WTC_000318160

Asbestos air sampling locations and results; all samples below standard with one indoor exceedance noted.

Similar indexed content

Air sampling locations, Dec 15, 2001

NYC-WTC_000321283

NYC/ER asbestos monitoring; Dioxin data notes and particulate monitoring constrained by weather; some results pending.

Similar indexed content

Compare copies and versions →