NYC Law Department release
Independent mirror · updated as the City releases more · v1.5.1
☕ Buy me a coffee
← Document results/Unboxed/No folder label
Document / 6 pages

EPA air/bulk sampling, Oct 24, 2001

Machine-extracted title · confidence 46%

Comprehensive asbestos air sampling results across NYC ER and Fresh Kills sites; most below standard.

NYC-WTC_000287596–000287601
Page image
Page image not rendered yet.
The pipeline renders page images incrementally; check back or read the OCR text alongside.
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document

Ambient Air Sampling Locations NYC / ER (Oct 8) - Silicates

o All 10 samples did not detect any silicates. NYC / ER (Oct 8) - Dioxin o 4 of the 10 samples (Location B, 3, Cl, and D) collected were above the EPA Removal Action guidelines (based on a 30-year exposure). o No samples were identified above the EPA Removal Action level guidelines adjusted to a 1-year exposure duration. o Levels do not pose a short-term health concern. However, elevated sufficiently to be of concern for long-term (chronic exposure). NYC / ER (Oct 22) - Particulate Monitoring (PXL 5) o Pace University (Site 1) - 24-hr average concentration for this period was 25.85 ug/n^. o Manhattan Boro Community College (Site 2) - 24-hour average concentration for this period was 22.59 ug/nr’. o Coast Guard Building - Battery Park (Site 3) - 24-hour average concentrations for this period was 21.87 ug/tn’. o All readings below the National Ambient Air Quality Standard for PM, 5 (65 ug/m^). NYC / ER (Oct 23) - Particulate Monitoring (Dataram) o Particulate levels noted at three locations (Stations L, N, R) were below the OSHA TWA. o Instruments operated between 6 to b'T hours. o Station L values ranged from 58.0 to 262.9 ug/m3 with an average of 118.4 ug/m\ o Station N values ranged from 80.9 to 193.5 ug/m3 with an average of 120.3 ug/m’. o Station R values ranged from 81.5 to 172.5 ug/m3 with an average of 108.1 ug/m'. NYC / ER (Oct 23) - Volatile organics (TAGA) o Benzene exceeded OSHA TWA PEL (1 ppm) at two locations on the debris pile in the plume at ground level. o Chlorodifluoromethane (Freon-22) continues to be noted as a Tentatively Identified Compound (TIC) at apparently significant concentrations in samples collected from the debris pile in the plume at ground level. o 2 separate samples collected at the North Tower location (3 hours apart) both tentatively identified chlorodifluoromethane (Freon-22). o Similarly, 2 separate samples collected on October 22 at the North Tower location (4 hours apart) both tentatively identified chlorodifluoromethane (Freon-22). o Note: Yesterday’s VOC results were from samples collected on Oct 22 (the Sampling Situation Report cover page identified the date as Oct 21). Bulk/Dust Samples NYC / ER (Oct 8) - Dioxin o 2 dust samples obtained from rooftops in the vicinity of the WTC (22 Cortlandt, 7* fl. and 600 Gateway Plaza, 34* fl.) o All samples below the EPA residential cleanup goal of 1 ppb.

CITY_DEP_WORBY_CANNATA_SUBP_000030168

NYC-WTC_000287598

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000287598Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Compare copies and versions →