Asbestos air sampling locations, NYC ER Feb 2002

Machine-extracted title · confidence 28%

EPA/DEP asbestos sampling locations with notes on sample counts and equipment issues, Feb 2002.

NYC-WTC_000287267–000287268
Page image
Page image not rendered yet.
The pipeline renders page images incrementally; check back or read the OCR text alongside.
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document

Ambient Air Sampling Locations

NYC / ER (Jan 21 - Jan 28) - Dioxin (EPA-ORD) o Six (6) 72-hour samples were collected during this period at Park Row (2 samples), Chambers St./West St. (2 samples), and Albany St. (2 samples) at roof top locations. o None of the samples collected were above the EPA Removal Action guidelines (based on a 30-year exposure). o Note: The analytical results for all but one of these samples (Park Row during the period January 21 -24) indicate that dioxin is not present in these air samples at levels sufficiently above those in the control samples to be considered a valid result. o Data is not attached.

NYC / ER (Feb 2 - 4) - Asbestos Monitoring (Particulate Monitoring Stations) o Monitoring sites include: Park Row (Site 1) Chambers St./West St. (Site 2) Public School 154: 333 East 135*** St. Bronx (Site 5) Intermediate School 143: 511 West 182"‘' St.. Manhattan (Site 6) Public School 274: 800 Bushwick Ave.. Brooklyn (Site 7) Public School 44: 80 Maple Parkway. Staten Island (Site 8) Public School 199: 3290 - 48"’ Ave.. Queens (Site 9) o During this period a total of 21 samples were collected from these monitoring sites. o All of the samples were below the TEM AHERA standard. o Resubmittal: Corrected spreadsheet for Feb. 1 attached. No changes in results. NYC / ER (Feb 11) - Particulate Monitoring (Dataram) o Particulate levels noted at two locations (Stations L and R) were below the OSHA TWA. o Equipment malfunction at Station N. o Instruments operated approximately 8 hours. o Station L had an average of 7.42 ug/m’ with a maximum reading of 80.51 ug/m\ o Station R had an average 8.17 ug/m^ with a maximum reading of 45.52 ug/m\

NYC / ER (Feb 11) - Volatile Organics (Mobile Laboratory) o Aside from two compounds detected from a ground level plume sample at the South Tower, volatile organic compounds were not detected above the detection limit (20 ppbv) in any of the four samples collected (Washing Tent, Austin Tobin Plaza, North Tower, and South Tower).

CITY_21MC100_002967537

NYC-WTC_000287268

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000287268Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Air sampling locations, Jan 25, 2002

NYC-WTC_000321287

NYC/ER asbestos sampling across multiple days; all samples below TEM AHERA; equipment malfunctions caused some misses.

Similar indexed content

Compare copies and versions →