NYC 9/11 Public Portal Document
Jessica Leighton - RA_sitrep12-28.wpd
U.S. Environmental Protection Agency (www.epa.gov)
Sampling Situation Report
Friday, December 28, 2001
Ambient Air Sampling Locations
NYC / ER (Dec 3 - Dec 13) - Dioxin (EPA-ORD)
o Five (5) 72-hour samples were collected during this period at Park Row (3 samples)
and Chambers St./West St. (2 samples) at roof top locations.
o None of the samples collected were above the EPA Removal Action guidelines (based
on a 30-year exposure).
o Data is not attached.
NYC / ER (Dec 27) - Particulate Monitoring (Dataram)
o Particulate levels noted at three locations (Stations L, N, R) were below the OSHA
TWA.
o Instruments operated approximately b'A to 7 hours.
o Station L values ranged from 0.0 to 685.2 ug/m’ with an average of 30.9 ug/m\
0 Station N values ranged from 14.6 to 61.6 ug/m" with an average of 21.4 ug/m\
o Station R values ranged from 3.0 to 86.5 ug/m’with an average of 20.5 ug/m\
NYC / ER (Dec 27) - Volatile Organics (Mobile Laboratory)
o Benzene exceeded OSHA TWA PEL (1 ppm) at one location (North Tower) in the
debris area at ground level.
o 2 of the 3 of the other samples (Washing Tent and South Tower) did not note any
benzene above the detection limit (ranging from 20 ppbv to 50 ppbv).
Direct Reading Instruments
NYC / ER (Dec 27)
o Nothing of significance reported.
CITY_21MC100_002458787
NYC-WTC_000321212