NYC Law Department release
Independent mirror · updated as the City releases more · v1.5.1
☕ Buy me a coffee
← Document results/Unboxed/No folder label
Document / 19 pages

Analysis of aerosols, WTC site, 2001

Machine-extracted title · confidence 38%

Continuation of aerosol analysis results from WTC site across multiple institutions.

NYC-WTC_000354229–000354247
Page image
Page image not rendered yet.
The pipeline renders page images incrementally; check back or read the OCR text alongside.
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document

168 T A. CAHILL ET AL.

While relative time accuracy is excellent (<3 h in 4 weeks), interferences and are not routinely quantified. The measure- absolute times are uncertain because of the finite width of the ment.s are made in a vacuum, which allows elements as light beginning and ending deposits on the Mylar strip, backlash in as carbon to be seen, but self absorption corrections make quan­ the gearing, etc. Normal DELTA Group protocols call for a blank tification very difficult. The X-rays are detected by a digital region in the middle of each strip for time and blank calibration Si(Li) detector and electronics, and calibration is accomplished and for a fixed ultrafine after filter, neither of which could be through 65 thin National Institute ol Standards and Technology implemented in the short time available. Thus, absolute time.s (NIST) traceable elemental standards and 12 certified elements, are given with an estimated maximum error of 6 li. Al-Pb, in NIST Standard Reference Materials (SRMs) 1832 and 1833. The results are reduced in the DELTA Group version of the Hydrogen by PESA International Atomic Energy Agency’s preferred code, AXIL. Hydrogen was measured by PESA (Cahill et al. 1989, 1990, Accuracy and precision have been verified by repealed analyses 1996; Malm et al. 1994) at CAMS, LLNL, which is also de­ and blind intercomparisons with IMPROVE (0.99 ± 0.04) and scribed in Bench et al. (2002). The time and spatial resolution California Air Resources Board (CARB) (1.02 ±0.11) filters wa.s identical to that of the STIM analyses, roughly 1 h resolu­ (DQAP ver. 7.02, 2002). The minimum detectable limit in a tion taken every 45 min. The strips had already been exposed to 30 .s analysis is around 0.2 ng/cm- for most element.s other than vacuum in the STIM analyses and were additionally exposed to the exceptions (above), which converts to 0.004 ng/m’ for the vacuum during the PESA analyses, which removes unbound or 6 week DRUM sampler used in th s study. An example of the lightly bound water and some fraction of volatile constituents. integration of these data with mass by STIM and hydrogen by primarily organic matter and some nitrates. Thus, the remain­ PESA is given in Bench et al. (2002). ing hydrogen is primarily found in inorganic ions and organic matter. With knowledge of the chemical state of major ions, the RESULTS remaining hydrogen has been found to be closely associated with organic matter (Cahill et al. 19.89, 1990, 1996). This has been in­ Single Particle Analysis dependently verified in over 100,000 ambient aerosols sampled The impaction of particles onto the lightly greased fiat Mylar in Ihe past 14 years a,s part of IMPROVE (Interagency Monitor­ substrate made single particle analysis possible for both coarse ing of Protected Visual Environments) quality assurance proto­ and fine particles. Samplers were analyzed on the actual sub­ col (Malm et al. 1994; IMPROVE 1988-2002), which directly strates without attempts at removal, which necessilate.s remov­ compare.s Organic Matter by Carbon (OMC) by combustion to ing a small portion of the DRUM strip onto a SE.M stem for organic matter via PESA (OMH). Despite the fact that the.se analysis. measurements for IMPROVE were made on different substrates Figure la shows an example of particles from aerodynam- (fired quartz for OMC, stretched Teflon for OMH) by different ically defined stage. Stage #2, from 5.0 to 2.5 pm diameter, laboratories, with OMC in air and OMH in vacuum, the results while Figure lb shows the same period but for particles from arc very well correlated, with a slope with ±10% of unity. 0.26 to 0.09 /rm diameter. The SLIM data represent the period that occurred on October 4, a period which will later be as­ Elemental by S-XRF signed to WTC plume impact, and had the highe.st value for The concentration of elements from sodium through molyb­ very fine silicon. In Figure la, in addition to the large number denum and selected heavy elements was established by syn­ of particles in the aerodynamically selected 5 to 2 5 /xm range, chrotron X-ray fluorescence (S-XRF) on the DELTA Group there are what appear to be large agglomerated flakes that would Beam Line 10.3.1. X-ray microprobe at the Advanced Light normally he aerodynamically sized along their thinnest aspect, Source, Lawrence Berkeley National Laboratory (ALS, LBNL). as would the one fiber roughly 25 pm long. In all the pictures S-.\RF is X-ray fluorescence in which the primary excitation taken, only one other asbestos-like fiber was seen, 120 pm long, .source consists of polarized X-ray.s from a synchrotron. We have collected in the coarsest size mode '^12 to 5.0 pm equivalent used thi.s technique on sample.s from the Kuwaiti oil fires at the aerodynamic diameter. Figure 1 b shows the silicon particles are .Stanford Linear Accelerator (Cahill 1992; Reid 1994), and it is indeed very fine, 0.26 > Dp > 0.09 pm diameter. The electron becoming more widely appreciated (Khodzheret al. 2000) as a beam of the SEM system wa,s used to detect numerous silicon- tool for aerosol analysis. The advantages are many, including re­ containing particles belnw the .surface of roughly 3 pm-thick moval of more than 95% of the X-ray background due to the po­ grease antibounce coating. The silicon particles appear to have larization of the beam and Ihe ability to focus the beam into small been imbedded in the grease of the surface coating because of area.s due to ALS’s extraordinary source brightness. Through the high (sonic) speed of impact during collection, while the use of a “white" beam covering 4 keV < Ex < 18 keV, possible sulfate particle,s stayed on the hydrophobic grease surface. The because of the polarization, all elements between sodium and presence of large amounts of sulfur was confirmed in the elon­ uranium can be simultaneously measured. However, in realis­ gated particles, which appear to be generated by postcollection tic ambient samples, the elements from molybdenum through aggregation. The alignment wa.s parallel to the air How over the Ilie rare earths and some heavy element.s usually have seriou,s sample. This is in accord with both the PESA hydrogen data

CITY_21MC100_006698491

NYC-WTC_000354232

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000354232Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Buildings in this record

Machine-extracted building matches; verify each source. Buildings, never households.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Compare copies and versions →