NYC-WTC_000354210
Academic article detailing aerosol analysis from WTC site with multi-institution collaboration.
31 shared non-person entities · 1 shared topics · similarity 0.999
machine-extracted · confidence unavailable · Check page ↗Continuation of aerosol analysis results from WTC site across multiple institutions.
NYC-WTC_000354229–000354247OCR status: ok · source: pdftotext
NYC 9/11 Public Portal Document
WORLD TRADE CENTER AEROSOL 167
Table 1 Parameters of the DELTA DRUM slotted drum impactor
Stage W (s) L S P out u out ECD W (d) A True no. (cm) (cm) (cm) (kPa) Re (rn/s) (ae, p,m) (/rm) (h)
! 0.360 0.65 1.44 101.3 2231 7.7 5.0 750 4.5 2 0.163 0.65 0.65 101.1 2810 17.1 2.5 500 3.0 3 0.073 0.65 0.29 100.2 3195 38.3 1.15 300 1.8 4 0.049 0.65 0.20 98.3 3331 58.3 0.75 265 1.6 5 0.038 0.65 0.15 94.9 3416 77.4 0.56 240 1.4 6 0.026 0.65 0.11 86.8 3575 122.2 0.34 245 1.8 7 0.024 0.65 0.10 75.1 3692 156.0 0.26 180 0.9 8 0.021 0.65 0.10 39.7 4595 315.9 0.09 175 0.9
The widih of the mass at full width, half maximum. W mass, represents the measured footprint of a noiirotating DRUM, accurate to about ±15%. This results in a resolution in time u.sing a 42 day rotation period (4 mm/day) given in T (h). The after fdter was not used in this work.
The effective time resolution At i.s thus set by the width of the 5. Elemental; Na-U, synchrotron x-ray fluorescence (in vac deposit and the rotation rate of the DRUM sampler. It is best for uum) (S-XRF), digital Si (Li) analysis at Advanced Light the finest stages, which for the 6 week rotation rate (4 inm per Source, Lawrence Berkeley National Laboratory (LBNL). 24 hr day for thi.s work) delivers a time resolution of about 1 h. 6. Speciated organic matter: laser desorption ionization time- The time resolution on the coarser stages is not as great as the of-flight mass spectrometry (LDITOF/MS) (in vacuum) at physical dimension of the slot. The observed width of deposit UCD. W (d) i.s much smaller on the coarse stage.s than the slot width 7. Size and morphology: scanning electron microscopy W (s), resulting in improved time resolution, ATime, three to (SEM) with X-ray analysis (in vacuum, using small pieces four times better than would have been expected from the slot of the strip) at UCD. width alone. This difference decreases in the finer stages until We will emphasize in this report mass data from scanning the observed width is about 85% of the slot width. The DRUM transmission ion microscopy (STIM), hydrogen data from pro protocol delivered a lime resolution approximating 1 to 1.-5 h ton elastic scattering analysis (PESA), and elemental data from for the fine (PMy 5) stages, although better resolution could be Synchrotron-induced X-Ray Fluorescence (S-XRF), while other obtained using a deconvolution protocol. results will be used to help clarify and interpret these primary data. SAMPLE ANALYSIS Samples were received at Davis shipped on the drums used Mass by STIM to collect the particles. Samples were di-smounted according to Mass was measured in vacuum by STIM using the 3 MeV DRUM protocols and transferred to stiff plastic frames foranaly- proton microprobe of the Center for Accelerator Mass Spec- sis.Thefrumeswerecodedtoestablishthetimeatwhichthesam- irometry (CAMS), Lawrence Livermore National Laboratory pies were taken. Due to the nature of the study, we were unable (LLNL). This method is described in Bench et al. (2002), which to incorporate automatic time-marking protocols on the strips establishes the accuracy and precision of STIM on equivalent during sampling thus, increasing the uncertainty with which ab- samples in some detail. Mass was measured by the energy loss of solute time.s can be determined. the proton as itpas.ses through the Mylar substrate (480 ^tg/enr). Seven separate nondestructive technique.s routinely used by the grease coating (nominally 10 /rg/cm^), and the deposit with DELTA Group collaborators were applied to theWTC samples: a minimum detectable level equivalent to about 0.5 /xg/m’ in 1. Optical: color photography (macro lens) (in air) at UCD. clean DRUM samples. The STIM proton beam, which can be as 2. Mass; soft beta ray transmission for mass and quality as- narrow as 1 ^m, was set at a width of 125 /rm to match the width surance (Mass /)) (in air), at UCD. of deposit of the sampler which was equivalent to 45 min time 3. Mass; scanning transmission ion microscopy (STIM) to resolution forthe 4 mm/day DRUM rotation rate (Table l).Thus, measure high temporal resolution aerosol mass profiles the analysis width is slightly less than the width of deposit, giv- (Mass STIM) (in vacuum) at Center for Accelerator Mass ing an equivalent time resolution of about 1 h taken every 45 rain Spectrometry, Lawrence Livermore National Laboratory for the finest DRUM stages. The measurement wa.s made in a (LLNL). vacuum, which removes unbound or lightly bound water and 4. Hydrogen: Proton elastic scattering analysis (PESA) (in some fraction of volatile consfituents, primarily organic matter vacuum) at LLNL. and some nitrates.
CITY_21MC100_006698490
NYC-WTC_000354231
OCR can misread numbers and units. Confirm readings against the page image before using them.
Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.
NYC-WTC_000354210
Academic article detailing aerosol analysis from WTC site with multi-institution collaboration.
31 shared non-person entities · 1 shared topics · similarity 0.999
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000337884
Authored chain-of-custody for dust sampling following WTC collapse; multiple investigators listed.
18 shared non-person entities · 1 shared topics · similarity 0.958
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000407250
Dust study authors and affiliations for WTC post-collapse work.
18 shared non-person entities · 1 shared topics · similarity 0.957
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000289526
Draft environmental monitoring report for WTC area air sampling, Sept 2001.
18 shared non-person entities · 1 shared topics · similarity 0.956
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000290254
Chain of custody listing contributors for World Trade Center dust samples.
18 shared non-person entities · 1 shared topics · similarity 0.956
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000436285
Front-matter listing authors and affiliations for WTC dust sampling report series.
18 shared non-person entities · 1 shared topics · similarity 0.956
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000242195
Chain-of-custody list for environmental samples related to World Trade Center dust investigation, Health and Mental Hygiene.
18 shared non-person entities · 1 shared topics · similarity 0.956
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000301521
Draft background study for WTC air quality prepared by EPA Region 2 and NYC agencies.
18 shared non-person entities · 1 shared topics · similarity 0.956
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000246024
Chain-of-custody content referencing environmental health journal material from 2002.
18 shared non-person entities · 1 shared topics · similarity 0.958
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000277590
Author list and affiliations for WTC dust samples and health studies.
18 shared non-person entities · 1 shared topics · similarity 0.957
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000434418
Chain-of-custody listing authors and contributors for WTC dust study at various sites.
18 shared non-person entities · 1 shared topics · similarity 0.956
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000417640
Author list for WTC dust study; team affiliations and collaboration across agencies.
18 shared non-person entities · 1 shared topics · similarity 0.956
machine-extracted · confidence unavailable · Check page ↗Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.
NYC-WTC_000354210
Academic article detailing aerosol analysis from WTC site with multi-institution collaboration.
Similarity score 0.990 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000354210
Academic article detailing aerosol analysis from WTC site with multi-institution collaboration.
Similarity score 0.940 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000354210
Academic article detailing aerosol analysis from WTC site with multi-institution collaboration.
Similarity score 0.937 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000407227
Dust characterization list for WTC site, post-collapse.
Similarity score 0.933 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000301521
Draft background study for WTC air quality prepared by EPA Region 2 and NYC agencies.
Similarity score 0.932 (not a probability)
machine-extracted · confidence unavailable · Check page ↗Similarity score 0.932 (not a probability)
machine-extracted · confidence unavailable · Check page ↗Machine-extracted building matches; verify each source. Buildings, never households.
Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.
NYC-WTC_000354210
Academic article detailing aerosol analysis from WTC site with multi-institution collaboration.
Similar indexed content
NYC-WTC_000246024
Chain-of-custody content referencing environmental health journal material from 2002.
Similar indexed content
NYC-WTC_000337884
Authored chain-of-custody for dust sampling following WTC collapse; multiple investigators listed.
Similar indexed content
NYC-WTC_000407250
Dust study authors and affiliations for WTC post-collapse work.
Similar indexed content
NYC-WTC_000277590
Author list and affiliations for WTC dust samples and health studies.
Similar indexed content