NYC Law Department release
Independent mirror · updated as the City releases more · v1.5.1
☕ Buy me a coffee
← Document results/Unboxed/No folder label
Document / 19 pages

Analysis of aerosols from WTC site, 2001

Machine-extracted title · confidence 40%

Academic article detailing aerosol analysis from WTC site with multi-institution collaboration.

NYC-WTC_000354210–000354228
Page image
Page image not rendered yet.
The pipeline renders page images incrementally; check back or read the OCR text alongside.
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document

WORLD TRADE CENTER AEROSOL 167

Table 1 Pararneter,s of the DELTA DRUM slotted drum impactor

.Stage W (s) L S P out u out ECD W (d) ATime no. (cm) (cm) (cm) (kPa) Re (nVs) (ae, /rm) (/rm) (h)

I 0.360 0.65 1.44 101.3 2231 7.7 5.0 750 4.5 2 0.163 0.65 0.65 101.1 2810 17.1 500 3.0 .3 0.073 0.65 0.29 100.2 3195 38.3 1.15 300 1.8 4 0.049 0.6.5 0.20 98.3 3331 58.3 0.75 265 1.6 .5 0.038 0.65 0.15 94.9 3416 0.56 240 1.4 6 0.026 0.65 0.1 I 86.8 3575 0.34 245 1.8 0.024 0.65 0.10 75.1 3692 156.0 0.26 180 0.9 8 0.021 0.6.5 0.10 39.7 4595 315.9 0.09 ■ 175 0,9

The width of the mass at full width, half maximum, W rnas.s, represents the measured footprint of a nonroiating DRUM, accurate to about ±15%. This results in a resolution in time using a 42 day rotation period (4 nim/day) given in 1’ (h). The after filter wa.s not used in this work.

The effective time resolution At is thu.s set by the width of the 5. Elemental: Na-U, synchrotron x-ray fluorescence (in vac­ deposit and the rotation rate of the DRUM sampler. It is best for uum) (S-XRF), digital Si (Li) analysi.s at Advanced Light the fine.st stages, which for the 6 week rotation rate (4 mtn per Source, Lawrence Berkeley National Laboratory (LBNL). 24 hr day for this work) delivers a time resolution of about I h. 6. Speciatcd oiganic matter: laser desorption ionization liine- The time resolution on the coarser stages is not as great as the of-Hight mas.s spectrometry (LDITOF/MS) (in vacuum) at physical dimension of the slot. The observed width of depo.sit UCD. W (d) is much smaller on the coarse stages than the slot width 7. .Size and morphology: scanning electron microscopy W (s), resulting in improved time resolution, ATime, three to (SEM) with X-ray nualysrs (in vacuum, using small pieces four times belter than would have been expected from the slot of the strip) at UCD. width alone. Thi.s difference decreases in the liner stages until We will emphasize in thi.s report mas.s data from scanning the observed width is about 85% of the slot width. The DRUM traiisiius.sioii ion microscopy (STIM), hydrogen data from pro­ protocol delivered a time resolution approximating 1 Io 1.5 h ton elastic scaltering analysis (PESA), and elemental data from for the fine (PMi 5) stages, although better resolution could be Synchrotron-in Juced X-Ray Fluorescence (S-XRF), while other obtained using a deconvolution protocol. results will be used to help clarify and interpret these primary data. SAMPLE ANALYSIS .Samples were received al Davis shipped on the drums used Mass by STIM to collect the particles. Sample.s were dismounted according to Mass was measured in vacuum by STIM using the 3 MeV DRUM protocols and transferred to stiff plastic frames for analy­ proton microprobe of the Center for Accelerator Mas,s Spec­ sis. The frames were coded to establish the time at which the sam­ trometry (CAMS), Lawrence Livermore National Laboratory ple.s were taken. Due to the nature of the study, we were unable (LLNL). This method i.s described in Bench et al. (2002), which to incorporate automatic lime-marking protocols on the strips establishes the accuracy and precision of STIM on equivalent during sampling thus, increasing the uncertainty with which ab­ samples in some detail. Mass wa.s measured by the energy los.s of solute times can be determined. the proton as it passe.s through the Mylar substrate (480 /ag/cm"), Seven separate nondestructive technique,s routinely used by the grease coating (nominally 10 gg/cm’), and the deposit with DELTA Group collaborators were applied to the WTC samples: a minimum detectable level equivalent to about ()..5 yrg/m’ in I. Optical: color photography (macro lens) (in air) at UCL5. clean DRUM samples. The STIM proton beam, winch can be as 2. Mass: soft beta ray transmis.sion for mass and quality as­ narrow as I /am, was set at a width of 125 /am to match the width surance (Mass 6) (in air), at UCD. of deposit of the sampler which was equivalent to 4.5 min time 3. Mass: scanning transmission ion microscopy (STIM) to resolution for the 4 mm/day DRUM rotation rate (Table 1). Thus, measure high temporal resolution aerosol mass profiles the analysis width is slightly le.s.s than the width of deposit, giv­ (Mas.s STIM) (in vacuum) at Center for Accelerator Mass ing an equivalent time resolution of about I h taken every 45 min Spectrometry, Lawrence Livermore National Laboratory for the finest DRUM stages. The measurement wins made in a (LEND. vacuum, which removes unbound or lightly bound water and 4. Hydrogen: Proton elastic scattering analysis (PESA) (in some fraction of volatile constitueiils, primarily oiganic matter vacuum) at LLNL, and some iiilrales.

CITY_21MC100_006698455

NYC-WTC_000354212

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000354212Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Buildings in this record

Machine-extracted building matches; verify each source. Buildings, never households.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Compare copies and versions →