NYC Law Department release
Independent mirror · updated as the City releases more · v1.5.1
☕ Buy me a coffee
← Document results/Unboxed/No folder label
Document / 12 pages

Dust study authors and affiliations, WTC

Machine-extracted title · confidence 30%

Dust study authors and affiliations for WTC post-collapse work.

NYC-WTC_000407250–000407261
Page image
Page image not rendered yet.
The pipeline renders page images incrementally; check back or read the OCR text alongside.
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document

Articles • Dust/smoke aerosol after the collapse of the WTC - 9/11/2001

size) for determinacion of trace and toxic ele­ developed by MVA 1,4,6). Identified con­ together with a beaker of water to maintain ments by inductively coupled plasma spec­ stituents were then rated as to whether it was the relative humidity near 100%. After a 14- troscopy; ion chromatography was used to “common" (consistently found throughout day exposure, the samples were examined for determine the ionic and cationic components the sample) or “present” (detected but infre­ pinholes and discoloration. of the mass. Other portions of each total mass quently) (7-11). Thi.s designation does not ItaJionucliJes. We analyzed the sample were then extracted and analyzed for necessarily indicate the relative abundance of gamma spectrum of the samples using an organic constituents. We included materials a constituent by weight or volume within a EG&G/Ottec high-purity Ge detector that are typically measured in air or dust sam­ sample; it is an indictor of numerical abun­ (50% relative efficiency) gamma counter ples by gas chromatographic and mass spec- dance of a constituent. 1 he < 73 pm size (EG&G/Ortec Instruments, Inc., Oak trometric techniques; we then scanned for fraction portion was analyzed by scanning Ridge, TN). We analyzed approximately 50 unknown extracts using other mass spectro­ electron microscopy (SEM). which was per­ peaks based on statistical significance (count- scopic analyses. Other analyses completed on formed using a j EOL 6400 (JEOL Inc.. ing/lack of Interferences). The.se included these total mass samples included the mea­ Peabody. MA) equipped with a Noran thorium, uranium, actinium series, and pri­ surement of pH, corrosion, aerodynamic par­ Voyager energy dispersive X-ray analysis unit mordial radionuclides. Liquid scintillation ticle size for fine and coarse particle fractions, (Noran Instruments. Inc., Middleton, Wl) analyses were conducted for emissions on percentage of mass by particle sieving, general and both the secondary and backscattered the total dust and smoke samples using a radiation levels, and asbestos. Dettils on each modes. For SEM analysis, portions of the Packard Tri-Carb Model 2770 TR/SL analysis conducted on the three dust and particles from the sample were transferred to (Packard Instrument, Meriden, Cd). The smoke samples are provided below. conductive carbon tape and coated with a MDA for alpha radioactivity was 0.30 DP.M Morpholagic ant/ grauirnetric anttiyses. thin layer of carbon to provide a conductive (0.14 pCi) based on a NLST-traccable ^-®Ra The dust samples were characterized by both surface in the electron microscope. Using the standard (National Institute of Standards and gravimetric measurement of sieved size frac­ backscattered electron mode, the sample was Technology. Gaithersburg. .MD). When tions and by polarized light microscopy examined for particles that contained heavy placed in the liquid scintillation fluid, the analyses. Ilie samples were sieved using stan­ elements. This procedure is useful in locat­ WTC samples ate somewhat darket than the dard 4-inch diameter brass sieves (U.S. ing particles containing toxic metals such as backgrounds and calibration standard, which Standard Sieve Mesh 50 and 200) as reported lead and cadmium. Using the secondary may cause slight underreporting of rhe beta previously (■/). The gravimetric determina­ electron mode, the sample w.ts examined for activity due to quenching and standard-to- tions were made in triplicate with a SETRA particles that were consistent with asbestos sample efficiency bias. EZ2-500 electronic 3-place balance (Setra fibers. We performed X-ray elemental analy­ InJuetiDely coupleiipinsniti mass spec­ Systems, Inc., Boxborough. MA). All s-ample- sis (energy dispersive spectrometry) on each trometry (ICP-MS) analysis Jot trace and handling activities were performed inside a particle located for further study by either toxic elements. All samples were analyzed in hood with a HE PA exhaust filter. Samples the backscattered electron or secondary elec­ duplicate for trace or toxic elements. were separated into fibrous (lint) and nonfi- tron scans. We prepared the < 75 pm size Approxinaately 0.1 g of sample was accu­ brous fractions using tweezers under the fraction of the samples following the ASTM rately weighed and placed in a CE.M HP500 stcreomicroscopc. Indoor dust has been D6602 procedure (t5) and analyzed them microwave vessel (CEM Corporation, shown to be composed of both fibrous and with analytic electron microscopy using a Matthews, NC). Fisher optima concentrated nonfihrous fractions (5). 1 he fibrous and JEOL 1200, 100 kV scanning transmission nitric acid (10 niL) was then added to the nonfibrous pans are cxfx'cted to respond dif­ electron microscope equipped with a Noran vessels. The six sample vessels phis those of ferently to dust disruptions, which Include energy dispersive spccttomctiy X-ray analysis two method blanks were sealed and placed dean i ng p rocedu res. system. Each sample was subjected to mor­ in the CEM MARS microwave unit at 1,200 We determined the weight of the lint phologic and gravimetric analyses. watts for 5 min. The sample.s were allowed (plus attached fine nonfibrous particulate). Aeradyna?nic particle separation. 1 he to cool for approximately 15 min inside the The remaining particulate was then dry sieved samplc.s were first mechanically separated MARS unit and were then removed and at the following size fractions: > 300 pm (col­ using a sieve with a mesh size of 53 pm. The placed in the cold room for 1 hr at 4“C. lected on Mesh 50), 75—300 pm (collected on fraction of particles < 53 pm wa.s further sep­ After cooling, the samples were then diluted Mesh 200). < 73 pm (through Mesh 200). arated aerodynamically into three size frac­ to 50 niL. A 2-mL aliquot was then diluted The weight of each fraction was determined tions; 10-33 pm, 2.5-10 pm, and < 2.5 pm. to 8 ml fora final acid concentration of5%. and the relative weight percentages were then Particles were resuspended by a jet of filtered We scanned the samples for metals on a calcidated. The lint fraction is found in the air passing through an inlet (Wedding Inlet, Fissons PQ3 ICP/.MS (Fis.som Instruments. large (> .300 pm) fraction. The fractions were 10 pm cut size; Anderson Instrument Co., Inc.. Merrimac. MA) over a mass range of combined and examined by stereoniicroscopy Fultonville, NY) before entering a cyclone 9-238 at 1,350 watts, with a dwell tinae of using a Zeis: Stemi 2000 stcreomicroscopc with a cut size of 2.5 put (BGI, Inc., 1.000 pscc with 40 sweeps for a total acqui­ (Cari Zeiss. Inc.. Thornwood, NY) with a Waltham. MA). Particles between 10 and 2.5 sition time of 70 sec. We used high purity magnification range of 6.5x to 47x. The pm were collected by rhe cyclone, whereas multielement standard and NIS I A&B cali­ physical characteristics of the samples were particles < 2.5 pm. which penetrated through brant for quality control. Acceptable quality then analyzed using an Olympus BH-2 polar­ the cyclone, were collected on Teflon filters. assurance checks were deemed to be 100 ± ized light microscope (Olympus America, Corrosion. We evaluated the corrosive 20% of the certified values. Inc., Melville, NY) with a magnification properties of the dust samples using copper Ion ebromatograp/jy for ionic species and range of 40x to 1,000x. A visual estimate was mirrors. For each dust sample, a small pH analyses. Wc weighed the samples (Fisher made of the relative percentage by volume of amount was sprinkled onto a copper mirror Scientific XT Balance; Fisher Scientific. loosely aggregated separable fibrous lint (hair and a second copper mirror was set aside as a Pittsburgh. PA) and placed them in test + natural fibers t manmade fibeis). control; hence, there were a total of three tubes; aliquots of distilled, deionized water Each sample was characterized morpho- exposed mirrors and three controls. These were added to make a concentration of l('gZ.dlv for major con.stltuents using a form SIX mirrors were placed in a scaled container approximately 30 mg/ml.. The tubes were

tnviraamental Health Perspectives • vowme 110 I number 7 I July 2002 705

CITY_21MC100_006646571

NYC-WTC_000407252

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000407252Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Compare copies and versions →