Dust characterization at WTC site, authors

Machine-extracted title · confidence 40%

Co-authored report detailing dust characterization after WTC collapse.

NYC-WTC_000407202–000407213
Page image
Page image not rendered yet.
The pipeline renders page images incrementally; check back or read the OCR text alongside.
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document

Articles • Dust/smoke aerosol after the collapse of the WTC - 9/11/2001

size) for dcterniinarion of trace and toxic ele­ developed by MVA {4,6). Identified con­ together with a beaker of water to maintain ments by inductively coupled plasma spec­ stituents were then rated as to whether it was the relative humidity near 100%. After a 14- troscopy; ion chromatography was used to “common” (consistently found throughout day exposure, the samples were examined for determine the ionic and cationic components the sample) or “present” (detected but infre­ pinholes and discoloration. of the mass. Other portions of each total mass quently) (7-11). This designation does not Ratiionucltdes. We analyzed the sample were then extracted and analj’zed for necessarily indicate the relative abundance of gamma spectrum of the samples using an organic constituents. We included materials a constituent by weight or volume within a EG&G/Orccc high-puficy Ge detector that are typically measured in air or dust sam­ sample; it is an indictor of numerical abun­ (50% Tclative efficiency) gamma counter ples by gas chromatographic and mass spcc- dance of a constituent. The < 75 pni size (EG&G/Orcec Instruments, Inc., Oak rromccric techniques; we then scanned for fraction portion was analyzed by scanning Ridge, TN). We analyzed approximately 50 unknown extracts using other mass spectro­ electron microscopy (SEM). which was per­ |xaks based on statistical significance (count- scopic analyses. Other analyses completed on formed using a JEOL 6400 (JEOL Inc., ing/lack of interferences). These included these total mass samples included the mea­ Peabody, MA) equipped with a Noran thorium, uranium, actinium series, and pri­ surement of pH, corrosion, aerodynamic par­ Voyager energy dispersive X-ray analysis unit mordial radionuclides. Liquid .scintillation ticle size for fine and coarse particle fractions, (Noran Instruments, Inc., Middleton, WI) analyses were conducted for emissions on percentage of mass by particle sieving, general and both the secondary and backscattered the total dust and smoke samples using a radiation levels, and asbestos. Dcuilson each modes. For SEM analysis, portions of rhe Packard Tri-Carb Model 2770 'FR/SL analysis conducted on the three dust and particles from rhe sample were transferred to (Packard Instrument, Meriden, CT). The smoke samples are provided below. conductive carbon tape and coated with a MDA for alpha radioactivity was 0.30 DPM Aforj)holog/c aft J grrtutMeiric afialyses. thin layer of carbon to provide a conductive (0.14 pCi) based on a NIST-traceable ^^^Ra The dust samples were characterized by both surface in the electron microscope. Using the standard (Nacional Institute of Standards and gravimetric measurement of sieved size frac­ backscattered electron mode, the sample was Technology, Gaithersburg, MD). When tions and by polarized light microscopy examined for particles that contained heavy placed in rhe liquid scintillation fluid, the analyses. The samples were sieved using stan­ elements. This procedure is useful in locat­ WTC samples arc somewhat darker than the dard 4-inch diameter brass sieves (U.S. ing particles containing toxic metals such as backgrounds and calibration stanebrd, which Standard Sieve Mesh 50 and 200) as reported lead and cadmium. Using the secondary may cause slight underteponing of the beta previously (4). The gravimetric determina­ electron mode, the sample was examined for activity due to quenching and srandard-to- tions were made in triplicate with a SETRA particles that were consistent with asbestos sample efficiency bias'. EZ2-500 electronic 3-place balance (Setra fibers. We performed X-ray elemental analy­ ]n4uctii/e/y eoup/t'iJ pfasnia mass spre- Systems, Inc., Boxborough, MA). All sample­ sis (energy dispersive spectrometry) on each trofnetry (/CP-MS) analysis fir [race and handling activities were performed inside a particle located for further study by either to.xic elements. All samples were analyzed in hood with a HEPA exhaust filter. Samples the backscattered electron or secondary elec­ duplicate for trace or toxic elements. were separated into fibrous (lint) and nonfi- tron scans. We prepared the < 75 pm size Approximately 0.1 g of sample was accu­ brous fractions using tweezers under the fraction of the samples following the ASTM rately weighed and placed in a CEM HP500 stcreomicroscope- Indoor dust has been D6602 procedure (6) and analyzed them microwave vessel (CBM Corporation, shown to be composed of both fibrous and with analytic electron microscopy using a Matthews, NC). Fisher optima concentrated nonfihrous fractions (5). The fibrous and JEOL 1200, 100 kV scanning transmission nitric acid (10 mL) was then added to the nonfibrous parts are expected to respond dif­ electron microscope equipped with a Noran vessels. The six sample vessels plus those of ferently to dust disruptions, which include energy dispersive spectrometry X-ray analysis two method blanks were seated and placed cleaning procedures. system. Each sample was subjected to mor­ in the CEM MARS microw'ave unit at 1,200 We determined the weight of the linr phologic and gravimetric analyses. watts for 5 min. The samples were allowed (plus attached fine nonfibrous particulate). Aerody/tiiffiic j)article sejfaration. The to cool for approximately 15 min inside the The remaining paniculate was then dry sieved samples were first mechanieally separated MARS unit and w'crc then removed and at the following size fractions: > 300 pm (col­ using a sieve with a mesh size of 53 pm. The placed in the cold room for 1 hr at 4"C. lected on Mesh 50), 75-300 pm (collected on fraction of paiticles < 53 pm was further sep­ After cooling, the samples were then diluted Mesh 200), < 75 pm (through Mesh 200). arated aerodynamically into three size frac­ to 50 mL. A 2-mL. aliquot was (hen diluted The weight of each fraction was determined tions: 10—53 pm, 2.5-1 0 pm, and < 2.5 pm. to 8 mL for a final acid concentration of 5%- and the relative weight percentages were then Particles were resuspended by a jet of filtered We scanned the samples for metals on a calculated. The lint fraction is found in the air pa.ssing through an inlet (Wedding Inlet, Fissons PQ3 ICP/MS (Fissons Instruments, large (> 300 pm) fraction. The fractions were 10 pm cut size; Anderson Instrument Co., Inc., Merrimac. MA) over a mass range of combined and examined by stereomicroscopy Fultonville, NY) before entering a cyclone 9-238 ar 1,350 watts, with a dwell time of using a Zei.ss Scend 2000 stcreomicroscope with a cut size of 2.5 pm (BGl, Inc., 1,000 psec with 40 sweeps for a total acqui- (Carl Zeiss, Inc., Thornwood, NY) with a Waltham, MA). Particles between 10 and 2.5 sirion time of 70 sec. We used high purity magnification range of 6.5x to 47x. The pm were collected by rhe cyclone, whereas multielement standard and NIS F A&:B cali­ physical characteristics of the samples were particles < 2.5 pm, which jTenetrated through brant for quality control. Acceptable quality then analyzed using an Olympus BH-2 polar­ the cyclone, were collected on Teflon filters. assurance checks were deemed to be 100 ± ized light microscope (Olympus America. Corrosion. We evaluated the corrosive 20% of the certified values. Inc., Melville, NY) with a magnification properties of the dust samples using copper Ion chromatography fir ionic species and range of 40x to l,000x. A visual estimate was mirrors. For each dust sample, a small pH analyses. We weighed the s-imp!es (Fisher made of the relative percentage by volume of amount was sprinkled onto a copper mirror Scientific XT Balance; Fisher Scientific, loosely aggregated separable fibrous lint (hair and a second copper mirror was set aside as a Pittsburgh, PA) and placed them in test + natural fibers + manmade fibers). control; lienee, there were a total of three rubes; aliquots of distilled, deionized water Each sample was characterized morpho­ exposed mirrors and three controls. These were added to make a concentration of logically for major constituents using a form six mirrors were placed in a scaled container approximately 30 mg/mL. The tubes were

Environmental Health Perspectives • volume 110 I numbes 7 I July 2002 705

CITY_21MC100_006646045

NYC-WTC_000407204

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000407204Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Compare copies and versions →