NYC Law Department release
Independent mirror · updated as the City releases more · v1.5.1
☕ Buy me a coffee
← Document results/Unboxed/No folder label
Document / 12 pages

Chain-of-custody, dust sampling near WTC

Machine-extracted title · confidence 50%

Authored chain-of-custody for dust sampling following WTC collapse; multiple investigators listed.

NYC-WTC_000337884–000337895
Page image
Page image not rendered yet.
The pipeline renders page images incrementally; check back or read the OCR text alongside.
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document

Articles • Dust/smoke aerosol after the collapse of the WTC - 9/11/2001

.size) for determination of trace and toxic ele- developed by MVA (4,6). Identified con­ together with a beaker of water to maintain nicnts by inductively coupled plasma spec­ stituents were then rated as to whether it was the relative humidity near 100%. After a 14- troscopy; ion chromatography was used to “common” (consistently found throughout day exposure, the samples were examined for determine the ionic and cationic components the sample) or “present” (detected but infre­ pinholes and discoloration. of the mass. Other portions of each total mass quently) (7-/7). This designation does not Radionuclides. We analyzed the sample were then extracted and analyzed for necessarily indicate the relative abundance of gamma spectrum of the samples using an organic constitucnt.s. We included materials a constituent by weight or volume within a EG&G/Ortee high-purity Ge detector that are typically measured in air or dust sam- sample; it is an indictor of numerical abun­ (50% relative efficiency) gamma counter ple.s by gas chromatographic and mass spec- dance of a constituent. The < 75 pm size (EG&G/Ortec Instruments, Inc., Oak tromctric techniques; we then scanned for fraction portion was analyzed by scanning Ridge, TN). We analyzed approximately 50 unknown extracts using other mass spectro- electron microscopy (SEM), which was per­ peaks based on statistical significance (count- scopie analyses. Other analyses completed on formed using a JEOL 6400 (JEOL Inc., ing/lack of interferences). These included these total mass samples included the mea­ Peabody, MA) equipped with a Noran thorium, uranium, actinium series, and pri­ surement of pH, corrosion, aerodynamic par­ Voyager energy dispersive X-ray analysis unit mordial radionuclides. Liquid scintillation ticle size for fine and coarse particle fractions, (Noran Instruments, Inc., Middleton, Wl) analyses were conducted for emissions on percentage of mass by particle sieving, general and both the secondary and backscattered the total dust and smoke sample.s using a radiation levels, and asbestos. Details on each modes. For SEM analysis, portion.s of the Packard Tri-Carb Model 2770 TR/SL analysis conducted on the three dust and particles from the sample were transferred to (Packard Instrument, Meriden, CT). The smoke samples arc provided below. conductive carbon tape and coated with a MDA for alpha radioactivity was 0.30 DPM Morphologic and gravimetric analyses. thin layer of carbon to provide a conductive (0.14 pCi) based on a NIST-traceable ^-*Ra The dust simples were characterized by both surface in the electron microscope. Using the standard (National Institute of Standards and gravimetric measurement of sieved size frac­ backscattered electron mode, the sample was Technology, Gaithersburg, MD). When tions and by polarized light microscopy examined for particles that contained heavy placed in the liquid scintillation fluid, the analyses. The samples were sieved using stan­ elements. This procedure is useful in locat­ WTC samples are somewhat darker than the dard 4-inch diameter brass sieves (U.S. ing particles containing toxic metals such as background.s and calibration standard, which Standard Sieve Mesh 50 and 200) as reported lead and cadmium. Using the secondary may cause slight urderreporting of the beta previously (4). The gravimetric determina- electron mode, the sample was examined for activity due to quenching and standard-to- tion.s were made in triplicate with a SETRA particles that were consistent with asbestos sample efficiency bias. EZ2-500 electronic 3-place balance (Setra fibers. We performed X-ray elemental analy­ Inductively coupled plasma mass spec­ Systems, Inc., Boxborough, MA). All sample­ sis (energy dispersive spectrometry) on each trometry (ICP-MS) analysis for trace ana handling activitiet: were performed inside a particle located for further study by either toxic elements. /UI .samples were analyzed in hood with a HEPA exhaust filter. Samples the backscattered electron or secondary elec­ duplicate for trace or toxic elements. were separated into fibrous (lint) and nonfi- tron scans. We prepared the < 75 pm size Approximately 0.1 g of sample was accu­ brous fractions using tweezers under the fraction of the samples following the ASTM rately weighed and placed in a CEM HP500 stereomicroscope. Indoor dust has been D6602 procedure (6) and analyzed them microwave vessel (CEM Corporation, shown to he composed of both fibrous and with analytic electron microscopy using a Matthews, NC). Fisher optima concentrated nonfibrous fractions (.5). The fibrous and JEOL 1200, 100 kV scanning transmission nitric acid (10 mLl was then added to the nonfibrous parts are expected to respond dif­ electron microscope equipped with a Noran vessels. The six sample vessels plus those of ferently to dust disruptions, which include energy dispersive spectrometry X-ray analysis two method blanks were sealed and placed cleaning procedures. system. Each sample was subjected to mor­ in the CEM MARS microwave unit at 1,200 We determined the weight of the lint phologic and gravimetric analyses. wares for 5 min. The samples were allowed (plu.s attached fine nonfibrous particulate). Aerodynamic farticle separation. The to cool for approximately 15 min inside the The remaining particulate was then dry sieved samples were first mechanically separated MARS unit and were then removed and at the following size fractions: > 300 pm (col­ using a sieve with a mesh size of 5.3 pm. The plated in the cold room for 1 hr at 4°C. lected on Mesh 50). 75—300 pm (collected on fraction of particles < 53 pm was further sep­ After cooling, the samples were then diluted Mesh 200), < 75 pm (through Mesh 200). arated aerodynamically into three size frac­ to 50 mL. A 2-mL aliquot was then diluted The weight of each fraction was determined tions: 10-53 pm, 2.5-10 pm, and < 2.5 pm. to 8 ml, for a final acid concentration of 5%, and the relative weight percentages were then Particles were resuspended by a jet of filtered We scanned the samples for metals on a calculated. The lint fraction is found in the air passing through an inlet (Wedding Inlet, Fissons PQ3 ICP/MS (Fissons Instruments, large (> 300 pm) fraction. The fractions were 10 pm cut size; Anderson Instrument Co., Inc., Merrimac, MA) over a mass range ot combined and examined by stereomicroscopy Fultonville, NY) before entering a cyclone 9-238 at 1,350 watts, with a dwell time ol using a Zeiss Stemi 2000 stereomicroscope with a cut size of 2.5 pm (BGI, Inc., 1,000 psec with 40 sweeps for a total acqui­ (Carl Zeiss, Inc,, Thornwood, NY) with a Walthatn, MA). Particles between 10 and 2.5 sition time of 70 sec. We used high purity magnification range of 6.5x to 47x. The pm were collected by the cyclone, whereas multielement standard and NIST A&B cali­ physical characteristics of the samples were particles < 2.5 pm, which penetrated through brant for quality control. Acceptable quality then analyzed using an Olympus BH-2 polar­ the cyclone, were collected on Teflon filters. assurance checks were deemed to be 100 ± ized light microscope (Olympus America, Corrosion. We evaluated the corrosive 20% of the certified values. Inc., Melville, NY) with a magnification propertie.s of the dust samples using copper Ion chromatography for ionic species ana range of 40x to 1,0Q0x. A visual estimate was mirrors. For each dust sample, a small pH analyses. We weighed the samples (Fisher made of rhe relative percentage by volume of amount was sprinkled onto a copper mirror Scientific XT Balance; Fisher Scientific. loosely aggregated separable fibrous lint (hair and a second copper mirror was set aside as a Pittsburgh, PA) and placed them in test + natural fibers + manmade fibers). control; hence, there were a total of three tubes; aliquots of distilled, deionized water Each sample was characterized morpho­ exposed mirrors and three controls. These were added to make a concentration of logically for major constituents using a form six mirrors were placed in a sealed container approximately 30 mg/mL. The tubes were

Environmental Health Perspectives • volume 1101 number 71 July 2002 705

CITY_21MC100_011099352

NYC-WTC_000337886

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000337886Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Compare copies and versions →