NYC 9/11 Public Portal Document
Articles • Dust/smoke aerosol after the collapse of the WTC - 9/11/2001
size) for determination of trace and toxic ele developed by MVA (4,6). Identified con together with a beaker of water to maintain
ments by inductively coupled plasma spec stituents were then rated as to whether it was the relative humidity near 100%. After a 14-
troscopy: ion chromatography was used to “common” (consistently found throughout day exposure, the samples were examined for
determine the ionic and cationic components the sample) or “present” (detected but infre pinholes and discoloration.
of the mass. Other ponions of each total mass quently) (7-11). This designation does not Radionuclides. We analyzed the
sample were then extracted and analyzed for necessarily Indicate the relative abundance of gamma spectrum of the samples using an
organic constituents. We included materials a constituent by weight or volume within a EG&G/Ortec high-purity Ge detector
that are typically measured in air or dust sam sample; it is an indictor of numerical abun (50% relative efficiency) gamma counter
ples by gas chromatographic and mass spec- dance of a constituent. The < 75 pm size (EG&G/Ortec Instruments, Inc., Oak
trometric techniques; we then scanned for fraction portion was analyzed by scanning Ridge, TN). We analyzed approximately 50
unknown extracts using other mass spectro electron microscopy (SEM), which was per peaks based on statistical significance (count-
scopic analyses. Other analyses completed on formed using a JEOL 6400 (JEOL Inc., ing/lack of interferences). These included
these total mass samples included the mea Peabody, MA) equipped with a Noran thorium, uranium, actinium series, and pri
surement of pH, corrosion, aerodynamic par Voyager energy dispersive X-ray analysis unit mordial radionuclides. Liquid scintillation
ticle size for fine and coarse particle fractions, (Noran Instruments, Inc., Middleton, WI) analyses were conducted for emissions on
percentage of mass by particle sieving, general and both the secondary and backscattered the total dust and smoke samples using a
radiation levels, and asbestos. Details on each modes. For SEM analysis, portions of the Packard Tri-Carb Model 2770 TR/SL
analysis conducted on the three dust and particles from the sample were transferred to (Packard Instrument, Meriden, CT). The
smoke samples are provided below. conductive carbon tape and coated with a MDA for alpha radioactivity was 0.30 DPM
Morphologic and gravimetric analyses. thin layer of carbon to provide a conductive (0.14 pCi) based on a NIST-traceable ^^^Ra
The dust samples were characterized by both surface in the electron microscope. Using the standard (National Institute of Standards and
gravimetric measurement of sieved size frac backscattered electron mode, the sample was Technology, Gaithersburg, MD). When
tions and by polarized light microscopy examined for particles that contained heavy placed in the liquid scintillation fluid, the
analyses. The samples were sieved using stan elements. This procedure is useful in locat WTC samples are somewhat darker than the
dard 4-inch diameter brass sieves (U.S. ing particles containing toxic metals such as bacl^rounds and calibration standard, which
Standard Sieve Mesh 50 and 200) as reported lead and cadmium. Using the secondary may cause slight underreporting of the beta
previously (4}. The gravimetric determina electron mode, the sample was examined for activity due to quenching and standard-to-
tions were made in triplicate with a SETRA particles that were consistent with asbestos sample efficiency bias.
EZ2-300 electronic 3-place balance (Setra fibers. We performed X-ray elemental analy Inductively coupled plasma mass spec
Systems, Inc., Boxborough, MA). All sample sis (energy' dispersive spectrometry) on each trometry (ICP-MS) analysis for trace and
handling activities were performed inside a particle located for further study by either toxic elements. All samples were analyzed in
hood with a HEPA exhaust filter. Samples the backscattered electron or secondary elec duplicate for trace or toxic elements.
were separated into fibrous (lint) and nonfi- tron scans. We prepared the < 75 pm size Approximately 0.1 g of sample was accu
brous fractions using tweezers under the fraction of the samples following the ASTM rately weighed and placed in a CEM HP500
stereomicroscope. Indoor dust has been D6602 procedure (6) and analyzed them microwave vessel (CEM Corporation,
shown to be composed of both fibrous and with analytic electron microscopy using a Matthews, NC). Fisher optima concentrated
nonfibrous fractions (5). The fibrous and JEOL 1200, 100 kV scanning transmission nitric acid (10 mL) was then added to the
nonfibrous parts are expected to respond dif electron microscope equipped with a Noran vessels. The six sample vessels plus those of
ferently to dust disruptions, which include energy dispersive spectrometry X-ray analysis two method blanks were sealed and placed
cleaning procedures. system. Each sample was subjected to mor in the CEM MARS microwave unit at 1,200
We determined the weight of the lint phologic and gravimetric analyses. watts for 5 min. The samples were allowed
(plus attached fine nonfibrous particulate). Aerodynamic particle separation. The to cool for approximately 15 min inside the
The remaining particulate was then dry sieved samples were first mechanically separated MARS unit and were then removed and
at the following size fractions; > 300 pm (col using a sieve with a mesh size of 53 pm. The placed in the cold room for 1 hr ar 4°C.
lected on Mesh 50), 75-300 pm (collected on fraction of particles < 53 pm was further sep After cooling, the samples were then diluted
Mesh 200), < 75 pm (through Mesh 200). arated aerodynamically into three size frac to 50 mL. A 2-mL aliquot was then diluted
The weight of each fraction was determined tions: 10-53 pm, 2.5-10 pm, and < 2.5 pm. to 8 mL for a final acid concentration of 5%.
and the relative weight percentages were then Panicles were resuspended by a jet of filtered We scanned the samples for metals on a
calculated. The lint fraction is found in the air passing through an inlet (Wedding Inlet, Fissons PQ3 ICP/MS (Fissons Instruments,
large (> 300 pm) fraction. The fractions were 10 pm cut size; Anderson Instrument Co., Inc., Merrimac, MA) over a mass range of
combined and examined by stereomicroscopy Fultonville, NY) before entering a cyclone 9-238 at 1,350 watts, with a dwell time of
using a Zeiss Stemi 2000 stereomicroscope with a cut size of 2.5 pm (BGI, Inc., 1,000 psec with 40 sweeps for a total acqui
(Carl Zeiss, Inc., Thornwood, NY) with a Waltham, MA). Particles between 10 and 2.5 sition time of 70 sec. We used high purity
magnification range of 6.5x to 47x. The pm were collected by the cyclone, whereas multielement standard and NIST A&B cali
physical characteristics of the samples were panicles <2.5 pm, which penetrated through brant for quality control. Acceptable quality
then analyzed using an Olympus BH-2 polar the cyclone, were collected on Teflon filters. assurance checks were deemed to be 100 ±
ized light microscope (Olympus America, Corrosion. We evaluated the corrosive 20% of the certified values.
Inc., Melville, NY) with a magnification properties of the dust samples using copper Ion chromatography fir ionic species and
range of 40x to 1,000x. A visual estimate was mirrors. For each dust sample, a small pH analyses. We weighed the samples (Fisher
made of the relative percentage by volume of amount was sprinkled onto a copper mirror Scientific XT Balance; Fisher Scientific,
loosely aggregated separable fibrous lint (hair and a second copper mirror was set aside as a Pittsburgh, PA) and placed them in test
+ natural fibers + manmade fibers). control; hence, there were a total of three tubes; aliquots of distilled, deionized water
Each sample was characterized morpho exposed mirrors and three controls. These were added to make a concentration of
logically for major constituents using a form six mirrors were placed in a sealed container approximately 30 mg/mL. The tubes were
Environmental Health Perspectives • volume 1101 number 71 July 2002 705
CITY_21MC100_011199911
NYC-WTC_000290256
OCR can misread numbers and units. Confirm readings against the page image before using them.