NYC 9/11 Public Portal Document
Articles • Lioyetal.
tons) reduced to dust and smoke, and the and the other was on Market Street, one and fractions > 300 pm, 75-300 pm, and <75
previously unseen degree of pulverization of two city blocks, respectively, west of the East pm in diameter; and b} an aerodynamic sep
the building materials. A summary of rhe River between the Manhattan and Brooklyn aration for the particle size fractions of < 2.5
potentially present types of carcinogenic and Bridges. These cars appeared to have been in pm, 2.5-10 pm. and 10-53 pm in diameter,
noncarcinogenic materials was reported in their respective locations since 11 September, with a gravimetric sieving that separated the
EHP in November 2001 (7). but it is possible that each could have been particles > 53 pm in diameter before the
The dust and smoke would be inhaled by moved from an adjacent thoroughfare on the aerodynamic sizing of the samples. The sepa
individuals either directly or after the settled east side of NYC (FDR Drive). rations were based on the design or availabil
aerosol was resuspended by turbulence. One of the reasons for collecting samples ity of specific size separation techniques in
Deposition and retention of the dust and from these locations was to determine the laboratories.
smoke on surfaces inside homes, as well as the whether chemical composition and physical We selected all of the analyses described
residuals of dust and smoke remaining if resi morphology of the particles changed with above for the three bulk samples based on the
dences and building ventilation systems were distance from the V^C site. The samples nature of the events and the materials that
not properly cleaned before rehabitation, were collected using the protocols established could be associated with the buildings and
would be available for uptake by children and for surface soil collection in our studies of the the burning jet fuel. The collapse resulted in
adults via nondietary ingestion. Indoor dispersal of chromium-laden hazardous waste a pulverization of the buildings. Thus, it was
inhalation exposures would also be possible in Jersey City, New Jersey (2), and the important to complete morphologic analyses
because of resuspension from the ventilation National Human Exposure Assessment to obtain a general idea about the composi
system. Any large-particle inhalation could Surv'ey (3). After collection, all samples were tion and the structure of the particles that
also lead to ingestion exposure after particles stored in a 4°C room prior to sending the were produced from the building materials.
are cleared from the upper airways of the lung subfractions to individual laboratories for We conducted the organic analyses to deter
by mucocilliary clearance processes. analysis. We maintained chain of custody mine the chemical nature of the products of
A number of initial measurements made throughout sample transferal and analyses. incomplete combustion produced by the fires
by various organizations focused on the gen and to identify any other organic materials.
eral composition of the dust and smoke, Methods The inorganic analyses were completed to
with a primary concern being asbestos (7). Approach obtain quantitative information on the levels
The approach we used for analyzing the of various heavy' metals and other inorganic
three dust and smoke samples included The analyses conducted on each sample were materials present in the pulverized building
detailed measurement of the inorganic and based on the nature of the sources of the par materials and in the fire. Finally, we con
organic components of the mass and a gen ticles that were aerosolized on 11 September ducted the particle size analyses to provide a
eral characterization of the percent distribu 2001. The force of the collapse pulverized general description of the types and levels of
tion by mass or volume of various materials the two main WTC structures and several material available that could be inhaled and
present in each sample. adjacent low-rise buildings (e.g., WTC3, deposited in various locations within the
Samples of the total settled dust and WTC7); therefore, our analytic plan lung. These size-separated samples were
smoke were collected at three different loca included qualitative and quantitative analy stored for analyses of the same compounds in
tions. The first sample was collected from ses to detect construction and furnishing the individual size fractions. These results are
protected external ledges around the entrance debris, and combustible materials and prod the subject of future manuscripts.
of a building on Cortlandt Street, which is ucts of incomplete combustion associated
one block east of the WTC building com with the fires in each building. We accom TVnaiytic Methods
plex. The initial direction of the plume was plished the tasks by completing analyses to Because each of the total mass dust and
from west to east (Figure 1); thus, the other identify inorganic and organic constituents. smoke samples was determined to contain a
two samples were collected at locations to the We designed the first sets of analyses to complex mixture of materials, the analytic
east of Cortlandt Street. These two samples provide a general characterization of the con plan required the inclusion of a number of
were collected from 10-15 cm-thick deposits tent of the samples using a combination of different techniques for examining chemical
that were on the top of two automobiles microscopic techniques. This provided an and physical characteristics. Our approach
about 0.7 km from the WTC site. The auto opportunity to classify the general morphol included microscopic analysis to identify
mobiles were in locations protected from rain ogy’ and to focus the chemical analyses subse major components and the morphology of
that occurred on Friday, 15 September 2001. quently performed on each sample based on particles in each sample. Using stereomi
One automobile was located on Cherry Street, the types of materials detected by the micro croscopy, we estimated relative percentages of
scopic analyses. The second type of analyses larger particles and identified large dust com
.... included the inorganic analyses (including ponents. We used polarized light microscopy
trace and toxic elements, ionic species, and with microchemical testing to identify most
functional groups) and the organic analyses particles including minerals, building prod
[including polycyclic aromatic hydrocarbons ucts, and hair and fibers > 1 pm in diameter.
(PAHs), polychlorinated biphenyls (PCBs), We used scanning electron microscopy with
pesticides, dioxins, furans, phthalate esters, X-ray elemental analysis to identify metal
and general hydrocarbons]. All of these fragments, building product pieces, and other
analyses were performed exclusively on the particles < 1 pm. Transmission electron
'1'”’
UA' Ins
total of bulk samples.
The third set of analyses included the par
ticle size fractionation experiments on each
microscopy, with electron diffraction and X-
ray elemental analysis was used to identify
the smallest fraction of particles including
sample. We used two different approaches; zz) single asbestos fibrils and carbon soot.
Rgure 1. The WTC dust and smoke plume moving a gravimetric sieving analysis that separated We extracted the portions of each total
east on 11 September 2001. the mass of lint and nonfibrous material into mass sample (not differentiated by particles
704 VOLUME 1101 NUMBER 71 July 2002 • Environmental Health Perspectives
CITY_21MC100_011199910
NYC-WTC_000290255
OCR can misread numbers and units. Confirm readings against the page image before using them.