NYC Law Department release
Independent mirror · updated as the City releases more · v1.5.1
☕ Buy me a coffee
← Document results/Unboxed/No folder label
Document / 12 pages

Dust characterization list, WTC aftercollapse

Machine-extracted title · confidence 35%

Dust characterization list for WTC site, post-collapse.

NYC-WTC_000407227–000407238
Page image
Page image not rendered yet.
The pipeline renders page images incrementally; check back or read the OCR text alongside.
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document

Articles • Uoy et a].^

tons) reduced to dust and smoke, and the and the other was on Market Street, one and fractions > 300 pm, 75-300 pnr, and < 75 previously unseen degree of pulverization of two city blocks, respectively, west of the East pm in diameter; and /) an aerodynamic sep­ the building materials. A summary of the River between the Manhattan and Brooklyn aration for the particle size fractions of < 2.5 potentially present types of carcinogenic and Bridges. These cars appeared to have been in pm. 2.5-10 pm. and 10-53 pm in diameter, noncarcinogenic materials was repotted in their respective locations since 1! September, with a gravimetric sieving that separated the EHP in November 2001 (/). but it is possible that each could have been particles > 53 pm in diameter before the The dust and smoke would be inhaled by moved from an adjacent thoroughfare on the aerodynanric sizing of the samples. The sepa­ individuals cither directly or after the settled east side of NYC (FDR Drive). rations were based on the design or availabil­ aerosol was resuspended by turbulence. One of the reasons for collecting samples ity of specific size separation techniques in Deposition and retention of the dust and from these locaticin.s wa.s to determine the laboratories. smoke on surfaces inside homes, as well as the whether chemical composition and physical We selected all of the analyses described residuals of dust and smoke remaining if resi­ morphology of the particles changed with above for the three bulk sample; based on the dences and building ventilation systems were distance from the VTC site. The samples nature of the cvenr.s and the materials that nor properly cleaned before rehabitation, were collected using the protocols established could be associated with the buildings and would be available for uptake by children and for surface soil collection in our studies of the the burning jet fuel. The collapse resulted in adults via nondietary ingestion. Indoor disjrctsal of chromium-laden hazardous waste a pulverization of the buildings. Thus, it was inhalation exposrrtes would also be possible in Jersey City, New Jersey (2), and the important to complete morphologic analyses because of tesuspension from the ventilation National Human Exposure Assessment to obtain a general idea about rhe composi­ systena. Any large-particle inhalation could Suivey (3). Alter collection, all samples were tion and the structure of the particles that also lead to ingestion exposure after particles stored in a 4’C room prior to sending the were produced from the building materials. are cleared from the upper aiiways of the lung subfractions to individual laboratories for We conducted the organic antJyses to deter­ by nuicocilhaiy clearance processes. analysis. We maintained chain of custody mine the chemical nature of the products of A number of initial measurements made throughout sample transferal and analyses. incomplete combustion produced by the fires by various organizations focused on the gen­ and to identify' any other organic materials. eral composition of lire dust and smoke, Methods 7he inorganic analyses were completed to with a primary concern being asbestos (7). Approach obtain quantitative information on the levels The approach we used for analyzing the of various heavy ntetals and other inorganic three dust and smoke samples included The analyses conducrcLl on each sample were materials present in the pulverized building detailed measurement of the inorganic and ha.sed on the nature of the sources of the par­ materials and in the fire. Finally, we con- organic components of the mass and a gen­ ticles that were aerosolized on 1 1 September dticrcrT rhe particle size analyses to provide a eral characterization of the percent distribu­ 2001, The force of the collapse pulverized general description of the typesand levels of tion by mass or volume of various materials the two main WTC structures and several material available that could be inhaled and present in each sample. adjacent low-rise buildings (e.g., W'TC3, deposited in various locations within the Samples of the total settled dust and W'TC7); therefore, our analytic plan lung. These size-separated samples were smoke were collected at three different loca­ included qualitative and quantitative analy­ stored for analyse,; of the same compounds in tions. The first sample was collected from ses to detect construction and furnishing the individual size fractions. E'hcse results are protected external ledges around the entrance debris, and combustible materials and prod­ rhe subject of future manu.scriprs. of a building on Cortlandt Street, which is ucts of incomplete combustion associated one. block east of the YTC building com­ Analylic Methods with the fires in each building. We accom­ plex. The initial direction of the plume was plished the tasks by completing analyses to Bccau.se each of the tot.t! mass dust and from west to cast (Figure 1); thus, the other identify inorganic and organic constituents. smoke samples was determined to contain a two samples were collected at locations' to rhe W'e designed the first sets of analyses to complex mixture of materials, the analytic east of Cortlandt Street. 3 hese two samples provide a general characrerlz-rrlon of the Con­ plan required the inclusion of a number of were collected from 10-15 cm-thick deposits tent of the samples using a combination of different techniques for examining chemical that were on the top of two automobiles microscopic techniques. This provided an and physical chameteristics. Our approach about 0.7 km from rhe WTC site. The auto­ opportunity to classify the general morphol­ included microscopic analysis to identify mobiles were in locations protected from rain ogy and to focus the chemical analyses subse­ major components and the morphology of that occurred on Friday, 15 September 2001. quently performed-on each sample based on particles in each sample. Using stercomi- One automobile was located on Cherry Street, the types of materials detected by the micro­ ctoscopy, we estimated relative percentages of scopic analyses. The second type of analyses larger particles and identifier! large dust com- included the inorganic analyses (including fzonents. We used polarized light microscopy trace and toxic elements, ionic species, and with microchemical testing to identify mo,st functional groups) and the organic analyses particles including minerals, building prod­ [including polycyclic aromatic hydrocarbons ucts, and hair and fibers > I pm in diameter. (PAHs), polychlorinated biphenyls (PCBs), We used scanning electron microscopy with pesticides, dioxins, furans, phthalate esters, X-ray elemental analysis to identify metal and general hydrocarbons]. All of these fragments, building product pieces, and other

J? analyses were performed exclusively on the total of bulk samples. The third set of analyses included the par­ ticle size fractionation experiments on each particles < 1 pm. Transrnission electron microscopy, with electron diffraction and X- ray elemental analysis was. used to identify the smallest fraction of particles including sample. We used two different approaches: a) single asbestos fibrils and carbon srxrt. Figure 1. The WTC dust and smoke plume moving a gravimetric sieving analysis that separated We extracted the portions of each total east on 11 September 2001. the ma-ss of lint and nonfihrous material into m.i.s,s sample (not differentiated by particles

704 VOLUME 110 I NUMBER? I July 2002 • Environmental Health Perspectives

CITY_21MC100_006646362

NYC-WTC_000407228

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000407228Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Compare copies and versions →