WTC monitoring - sampling and analysis

Machine-extracted title · confidence 37%

WTC monitoring; sampling and analysis parameters for site-related samples.

NYC-WTC_000348867
Page image
Page image not rendered yet.
The pipeline renders page images incrementally; check back or read the OCR text alongside.
OCR text

OCR status: ok · source: pdftotext

z Z o WTC Indoor Air Monitoring - Sampling and Analytical Procedures o i 1^ Analytical co

Media Sp ’^pling Points Sampling Method Proposed Sampling Vulnerability/Practicality Analytical Method Proposed U o Parameters c o CT o o This is a micro vacuuming methcxl. Three collocated samples will be o' Carpels fabric furniture or Asbestos ASTM D 5755-95 ASTM D 5755-95 00 Porous Soft collected from each location. ■D 00 drapery i areas of activity O 03 surfaces 3. (living family rooms) This is a micro vacuuming method. Three collocated samples will be 03 Lead ASTM E 1973-99 SW-846 6010B collected from each location. o o Asbestos o c ASTM D 6480-99 Wipe Samples ASTM D 6480-99 (wipe) 3 CD Lead 3 Horiy'^ntal surfaces of ASTM E 1728 Wipe Samples SW-846 601 OB Non-porous tables O’ counters and bare Dioxins ASTM D 6661-01 Wipe Samples ASTM 6661-01/SW-846 8290 Hard floors, ceilings and walls in surfaces area'^ nf activity (living PAHs ASTM D 6661-01 Wipe Samples ASTM 6661-01/SW-846 8270C roo’-'s family rooms) Silica ASTM E 1728** Wipe Samples NIOSH 7500 (XRD)

MMVF ASTM D 6480-99 Samples will be combined with the asbestos sampling. EMSL MSD.0300

Air pump operated at 10L/min for 8 hours to achieve the PIC PCM NIOSH 7400 followed by TEM AHERA Asbestos NIOSH 7400 wkgroup detection limits method.

Air pump operated at lOL/min for 8 hours to achieve the PIC Lead NIOSH 7300 SW-846 601 OB wkgroup detection limits

TBD Pending sample volume PAHs requirements and to account for Pilot clean-up study only SW-846 8270 Are?" of known activity 7 break through on the cassettes. Indoor Air. (living ■ '■'’'ms, family rooms) / TBD Pending sample volume Pilot clean-up study only. Availability of sample cassettes for dioxins g Dioxins requirements and to account for SW-846 8290 analysis is questionable. Apparently the supply is low. break through on the cassettes. Air pump operated at 2.5L/min for 8 hours to achieve the PIC Silica NIOSH 7500 NIOSH 7500 (XRD) wkgroup detection limits Assumed that it behaves the same as asbestos, samples will be MMVF NIOSH 7400 EMSL MSD.0300 combined with the asbestos sampling.

NOTE: All samples c assettes and wipes) will be preweighed by the laboratory or supplier prior to sample collection. After sample collection and upon receipt of the samples by the laboratory, the laboratory will weigh the sample wipe or cass?"c prior to performing the analysis. This may change depending upon the availability of preweighed materials. May collect samples for total dust. O

K I ** Silica will be colleCed as a dust samples as is Lead. This was decided since pulverized silica would be particulate like and not fiber like as with asbestos and MMVF.

S O O o I o o to

O', rc

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000348867Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

NYC-WTC_000199864

Protocol document detailing micro vacuuming methods for collecting asbestos and lead samples from indoor surfaces at the World Trade Center site.

Similar indexed content

Compare copies and versions →