12 shared non-person entities · 1 shared topics · similarity 0.998
machine-extracted · confidence unavailable · Check page ↗Draft Statement of Work for indoor dust sampling in NYC
Machine-extracted title · confidence 90%Contractual document outlining services to collect and analyze dust samples for hazardous substances in selected New York City buildings.
NYC-WTC_000178163–000178169
OCR status: ok · source: pdftotext
NYC 9/11 Public Portal Document
ATTACHMENT 2
WTC Indoor Air Monitoring - Sampling and Analytical Procedures Analytical Media Sampling Points Sampling Method Proposed Sampling Vulnerability/Practicality Analytical Method Proposed Parameters
Carpets, fabric furniture or Settled drapery in areas of activity This IS a micro vacuuming method Three collocated samples will Dust Asbestos ASTM D 5755-95 ASTM D 5755-95 f'ving rooms, family be collected from each location. Porous rooms) Soft surfaces Lead This IS a micro vacuuming method Three collocated samples will ASTM E 1973-99 SW-846 601 OB be collected from each location
Hnrizontal surfaces of tables or counters and Asbestos ASTM D 6480-99 Wipe Samples ASTM D 6480-99 (wipe) bare floors, ceilings and walls in areas of activity (living rooms, family rooms) Lead ASTM E 1728 Wipe Samples SW-846 6010B Settled Dust Non-porou Dioxins ASTM D 6661-01 Wipe Samples ASTM 6661-01/SW-846 8290 sHard surfaces PAHs ASTM D 6661-01 Wipe Samples ASTM 6661-01/SW-846 8270C
Silica ASTM E 1728** Wipe Samples NIOSH 7500 (XRD)
MMVF ASTM D 6480-99 Samples will be combined with the asbestos sampling EMSL MSD.0300
AroAs of known activity Air pump operated at lOL/min for 8 hours to achieve the COPC PCM NIOSH 7400 followed by TEM AHERA P'ving rooms, family Asbestos----- .(JIOaHTTOO irjil wkgroup detection limits -T method rooms)------------ ,^OSH 7300 ; Air pi rnp (Iterated at lOL/min for 8 hours to achieve the COPC Lear SW-846 601 OB is? TBD"Penc!ihg-samjile“vdiCime j wkgroup detection limits
PAHS requirements and to account for Pilot clean-up study only SW-846 8270 break through on the cassettes Indoor Air TBD Pending sample volume Pilot clean-up study only Availability of sample cassettes for o Dioxins requirements and to account for SW-846 8290 dioxins analysis is questionable Apparently the supply is low. H break through on the cassettes.
Air pump operated at 2 5L/min for 8 hours to achieve the COPC to Silica NIOSH 7500 NIOSH 7500 (XRD) wkgroup detection limits S O Assumed that it behaves the same as asbestos, samples will be MMVF NIOSH 7400 EMSL MSD 0300 o combined with the asbestos sampling o I o NOTE All samples (cassettes and wipes) will be preweighed by the laboratory or supplier pnor to sample collection After sample collection and upon receipt of the samples by the laboratory, the laboratory will weigh the sample wipe or cassette pnor to performing the analysis This may change depending upon the availability of preweighed materials. May collect samples fortotaldust co co ** Silica will be collected as a dust samples as is Lead This was decided since pulverized silica would be particulate like and not fiber like as with asbestos and MMVF O', co rc rc
NYC-WTC_000178169
OCR can misread numbers and units. Confirm readings against the page image before using them.
Related records
Browse subjects →Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.
Same-box records
No available related records indexed in this group.
Filed elsewhere
12 shared non-person entities · 1 shared topics · similarity 0.998
machine-extracted · confidence unavailable · Check page ↗12 shared non-person entities · 1 shared topics · similarity 0.998
machine-extracted · confidence unavailable · Check page ↗12 shared non-person entities · 1 shared topics · similarity 0.998
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000176016
Draft contract document outlining the scope for collecting and analyzing settled and airborne dust samples in fourteen buildings.
11 shared non-person entities · 1 shared topics · similarity 0.993
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000162212
EPA staff distributed a chain of custody document to multiple federal and city agencies on May 15, 2002.
12 shared non-person entities · 1 shared topics · similarity 0.990
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000182053
Contract document outlining the scope for collecting and analyzing settled and airborne dust samples from buildings affected by Ground Zero dust.
12 shared non-person entities · 1 shared topics · similarity 0.990
machine-extracted · confidence unavailable · Check page ↗12 shared non-person entities · 1 shared topics · similarity 0.990
machine-extracted · confidence unavailable · Check page ↗12 shared non-person entities · 1 shared topics · similarity 0.989
machine-extracted · confidence unavailable · Check page ↗12 shared non-person entities · 1 shared topics · similarity 0.989
machine-extracted · confidence unavailable · Check page ↗12 shared non-person entities · 1 shared topics · similarity 0.989
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000178128
Contract statement of work for collecting settled and airborne dust samples in New York City buildings.
12 shared non-person entities · 1 shared topics · similarity 0.989
machine-extracted · confidence unavailable · Check page ↗More like this page
Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.
Similarity score 0.999 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000140461
Technical attachment specifying ASTM methods for collecting and analyzing asbestos and lead in settled dust from residential surfaces.
Similarity score 0.998 (not a probability)
machine-extracted · confidence unavailable · Check page ↗Similarity score 0.995 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000178128
Contract statement of work for collecting settled and airborne dust samples in New York City buildings.
Similarity score 0.994 (not a probability)
machine-extracted · confidence unavailable · Check page ↗Similarity score 0.994 (not a probability)
machine-extracted · confidence unavailable · Check page ↗Similarity score 0.993 (not a probability)
machine-extracted · confidence unavailable · Check page ↗Others also read
Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.
Similar indexed content
Similar indexed content
Similar indexed content
Similar indexed content
Draft contract document outlining the scope for collecting and analyzing settled and airborne dust samples in fourteen buildings.
Similar indexed content