NYC 9/11 Public Portal Document

ATTACHMENT 2

WTC Indoor Air Monitoring - Sampling and Analytical Procedures Analytical Vledia Sampling Points Parameters Sampling Method Proposed Sampling Vuinerabiiity/Practicaiity Analytical Method Proposed

This is a micro vacuuming method. Three collocated samples Jetfled Carpets, fabric furniture Asbestos ASTM D 5755-95 will be collected from each location. ASTM D 5755-95 Dust or drapery In areas of rous Soft activity (living rooms, This is a micro vacuuming method. Three collocated samples jrfaces family rooms) Lead ASTM E 1973-99 will be collected from each location. SW-846 6010B

Asbestos ASTM D 6480-99 Wipe Samples ASTM D 6480-99 (wipe)

Lead ASTM E 1728 Wipe Samples SW-846 601 OB

Dioxins .ASTM D 6661-01 Wipe Samples ASTM 6661 -01 /SW-846 8290

Horizontal surfaces of tables or counters and P7\Hs ASTMD 6661-01 Wipe Samples ASTM 6661-01 /SW-846 8270C iettled Dust bare floors, ceilings and 'n-porou walls in areas of activity Silica ASTM E 1728" Wipe Samples NIOSH 7500 (XRD) 5 Hard (living rooms, family jrfaces rooms) MMVF ASTM D 6480-99 Samples will be combined with the asbestos sampling. EMSL MSD.0300

Aar pump operated at lOL/min for 8 hours to achieve the COPC PCM NIOSH 7400 followed by TEM AHER? , Aisbestos NIOSH 7400 wkgroup detection limits method. Air pump operated at 1 OL/min for 8 hours to achieve the COPC Lead NIOSH 7300 wkgroup detection limits SW-846 601 OB

TBD Pending sample volume requirements and to account for PAHs break through on the cassettes. Pilot clean-up study only SW-846 8270

TBD Pending sample volume requirements and to account for Pilot clean-up study only. Availability of sample cassettes for Dioxins break through on the cassettes. dioxins analysis is questionable. Apparently the supply is low. SW-846 8290 Air pump operated at 2.5L/min for 8 hours to achieve the Silica NIOSH 7500 COPC wkgroup detection limits NIOSH 7500 (XRD) Areas of known activity (living rooms, family Assumed that It behaves the same as asbestos, samples will be door Air rooms) MMVF NIOSH 7400 combined with the asbestos sampling. EMSL MSD.0300

)TE: All samples (cassettes and wipes) will be preweighed by the laboratory or supplier prior to sample collection. After sample collection and upon receipt of the samples by the laboratory, the loratory will weigh the sample wipe or cassette prior to performing the analysis. This may change depending upon the availability of preweighed materials. May collect samples for total dust.

NYC-WTC_000178135

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000178135Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Compare copies and versions →