NYC 9/11 Public Portal Document
ATTACHMENT 2
WTC Indoor Air Monitoring - Sampling and Analytical Procedures
Analytical Sampling Method Proposed Sampling Vulnerability/Practicality
Media Sampling Points Analytical Method Proposed
Parameters
Carpets, fabric furniture or
Settled drapery in areas of activity This is a micro vacuuming method. Three collocated samples will
Dust (living rooms, family Asbestos ASTM D 5755-95 be collected from each location. ASTM D 5755-95
Porous rooms)
Soft
surfoces This is a micro vacuuming method. Three collocated samples vrill
Lead ASTM E 1973-99 SW-846 601OB
be collected from each location.
Horizontal surfaces of
tables or counters and Asbestos ASTM D 6480-99 Wipe Samples ASTM D 6480-99 (wipe)
bare floors, ceilings and
walls in areas of activitv
(living rooms, family
rooms) Lead ASTM E 1728 Wipe Samples SW-846 601 OB
Settled
Dust
Non-porou Dioxins ASTM D 6661-01 Wipe Samples ASTM 6661-01/SW-846 8290
s Hard
surfaces PAHs ASTM D 6661-01 Wipe Samples ASTM 6661-01/SW-846 8270C
Silica ASTM E 1728“ Wipe Samples NIOSH 7500 (XRD)
MMVF ASTM D 6480-99 Samples will be combined with the asbestos sampling. EMSL MSD.0300
Areas of known activity Air pump operated at lOL/min for 8 hours to achieve the COPC PCM NIOSH 7400 followed by TEM AHERA
(living rooms, family Asbestos—. wkgroup detection limits method.
----------rooms)---------
n erated at 10L/min for 8 hours to achieve the COPC
wkgroup detection limits SW-846 601 OB
PAHs requirements and to account for Pilot clean-up study only SW-846 8270
break through on the cassettes.
Indoor Air
TBD Pending sample volume
Pilot clean-up study only. Availability of sample cassettes for
Dioxins requirements and to account for SW-846 8290
break through on the cassettes. dioxins analysis is questionable. Apparently the supply is low.
Air pump operated at 2.5Umin for 8 hours to achieve the COPC
Silica NIOSH 7500 NIOSH 7500 (XRD)
wkgroup detection limits
MMVF NIOSH 7400 Assumed that it behaves the same as asbestos, samples will be
EMSL MSD.0300
combined with the asbestos sampling.
NOTE: All samples (cassettes and wipes) will be preweighed by the laboratory or supplier prior to sample collection. After sample collection and upon receipt of the samples by the laboratory, the laboratory will weigh
the sample wipe or cassette prior to performing the analysis. This may change depending upon the availability of preweighed materials. May collect samples for total dust
“ Silica will be collected as a dust samples as is Lead. This was decided since pulverized silica would be particulate like and not fiber like as with asbestos and MMVF.
NYC-WTC_000140461