NYC Law Department release
Independent mirror · updated as the City releases more · v1.5.1
☕ Buy me a coffee
← Document results/Unboxed/No folder label
Document / 1 page

WTC monitoring narrative, sampling plan and vulnerabilities

Machine-extracted title · confidence 28%

Overview page showing sampling, analytical notes and vulnerability considerations.

NYC-WTC_000353722
Page image
Page image not rendered yet.
The pipeline renders page images incrementally; check back or read the OCR text alongside.
OCR text

OCR status: ok · source: pdftotext

Z Z WTC Indoor Air Monitoring = Sampiing and Analytical Procedures o co

Analytical '2 o o Media Sampling Points Parameters Sampling Method Proposed Sampling Vulnerability/Practicality

"This test method does not describe procedures or techniques Analytical Method Proposed ■a c CT Ca5 o' tn required to evaluate the safety or habitability of buildings with U tfO Asbestos MicrovacASTM 5755-95 asbestos-containing materials, or compliance with federal, state, or ASTM 5755-95 O KJ 3. ro local regulations or statutes. It is the user's responsibility to make 91 these determinations." (Section 5.1.1 of method 5755-95) O o o Lead Microvac ASTM 5755-95" NIOSH 7300 c Carpets, fabric furniture or 3 Porous Soft After speaking with several people in HQ and RTP, it does not CD drapery in areas of activity Still checking on methods. Reached 3 surfaces appear there are standardized methods for the collection of these To be determined once the sampling method (if (living rooms, family rooms) Dioxins out to RTP and HQ. Waiting for parameters, rather many of the methods being used today are any) has be selected additional information research and development procedures, PAHs

Silica

See the comment for asbestos. Samples will be combined with the MMVF MicrovacASTM 5755-95 EMSL MSD.0300 asbestos sampling.

"This test method does not describe procedures or techniques required Io evaluate the safety or habitability of buildings with Wipe ASTM D 6480-99 or ASTM D 6480-99 (wipe) or Asbestos asbestos-containing materials, or compliance with federal, state, or MicrovacASTM 5755-95 ASTM 5755-95 (microvac) local regulations or statutes. It is the user's responsibility to make these determinations." (Section 5.1.1 of method 5755-95) Horizontal surfaces of Non-porous tables or counters and Lead NIOSH 9100 None known, wipe sampling has been legally defended. SW-846 6010B Hard barefloors, ceilings and surfaces walls in areas of activity Dioxins ASTM D 6661-01 ASTM 6661-01/SW-846 8290 (living rooms, family rooms) PAHs ASTM D 6661-01 ASTM 6661-01/SW-846 8270C

Silica See comment for silica above. See comment for silica above. See comment for silica above. Wipe ASTM D 6480-99 or Same as asbestos microvac. Samples will be combined with the MMVF EMSL MSD.0300 MicrovacASTM 5755-95 asbestos sampling. Air pump operated at 10L/min for 8 hours to achieve the PIC PCM NIOSH 7400 followed by TEM AHERA Asbestos NIOSH 7400 wkgroup detection limits method. Air pump operated at lOL/min for 8 hours to achieve the PIC o Lead NIOSH 7300 SW-846 601 OB Areas of known activity wkgroup detection limits Indoor Air H (living rooms, family rooms) Air pump operated at 2.5L/min for 8 hours to achieve the PIC K Silica NIOSH 7500 NIOSH 7500 (XRD) I wkgroup detection limits

S Assumed that it behaves the same as asbestos, samples will be MMVF NIOSH 7400 EMSL MSD.0300 o combined with the asbestos sampling. o o NOTE: All samples (cassettes and wipes) will be preweighed by the laboratory or supplier prior to sample collection. After sample collection and upon receipt of the samples by the laboratory, the laboratory will weigh I the sample wipe or cassette prior to performing the analysis. o co kO I** This method is for asbestos and is being modified for the collection of lead dust. Modification - to use the filter specified for method NIOSH 7300

CO

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000353722Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

NYC-WTC_000196444

Document outlining monitoring parameters and referencing ASTM 5755-95 for asbestos-containing material evaluation at the WTC site.

Similar indexed content

Compare copies and versions →