1 .c.b. J. C. Broderick & Associates Environmental Engineers

October 23, 2001

Mr. Howard Berman 69 Murray Street Housing Coop. 69 Murray Street New York, New York 10007

Re: Asbestos Air Monitoring Report Letter for Abatement Activities Performed on the Roof, 3rd Floor and Lobby Areas at 69 Murray Street New York, New York 10007 October 2001

JCB# 01-2273

Dear Mr. Berman:

J.C. Broderick & Associates, Inc. (JCB) was retained to perform asbestos air monitoring services during the abatement activities performed by Branch Services, Inc. at the above referenced locations. The air sampling and abatement activities were performed on October 17, 18, 19 and 20, 2001. The air sampling was performed by a JCB New York State certified air sampling technician in accordance with NYS Industrial Code Rule 56 Part 17. Samples were collected, chain of custody forms prepared, and delivered to an independent ELAP certified laboratory for analysis.

The samples were analyzed by Phase Contrast Microscopy (PCM) method. The NIOSH Physical and Chemical Analytical Method No. 7400 involves the collection of all airborne contaminants across the face of a mixed cellulose ester filter. Air is drawn across these filters utilizing miniature portable vacuum samplers as well as large volume vacuum pumps. Chemical treatment of the filter medium causes it to become transparent to allow examination and counting of fibers by PCM at 400X magnification. The criteria specified in this method for counting fibers are size and length to width ratio. Under this methodology, all fibers which meet these criteria are counted as asbestos.

Copies of the air sampling analytical reports are attached. The results of the PCM clearance sampling performed satisfies the clearance requirements established by NYS Industrial Code Rule 56 Part 17. Attached please find a copy of the chain of custody, lab analysis and a copy of JCB’s asbestos handling license.

If you have any questions or if more information is needed please call.

Sincerely,

Kevin J. Kortlang J.C. BRODERICK & ASSOCIATES, INC.

attach

lDl-4 Colin Drive, Holbrook, NY 11741-ThI: 631-419-0913 - 631-504-5492 • FAX: 631-504-3395

CITY_21MC100_003008591

NYC-WTC_000342882

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000342882Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

NYC-WTC_000342899

JCB report on ambient asbestos in air sampling; TEM analysis coordination, Oct 2001.

Similar indexed content

Compare copies and versions →