NYC 9/11 Public Portal Document ®004 FAX

Insignia Residential Group, Inc. JLG Project# 01 •'2094 September 20, 2001 □age 2 Air Sampling. and Procedure

Introduction Air sampling is defined as the process of measuring the filter content of a known volume of air entrained on a filter membrane over a specified period of time. Each sample is cross-referenced by field designation and a JLC lab internal code to ensure proper, consistent handling through a chain of custody. Sample preparation takes place within an HEPA filter clean bench to avoid any possible contamination.

Methodology Test procedures tor these samples conform to the National Institute of Occupational Safety and Health (NIOSH) standards.

Air sampling was conducted at a level approximating the breathing zone of persons anticipated to be present in the area during normal operations. Samples collected should represent the area's typical airborne fiber concentration.

All samples were collected on fully exposed 25 millimeter, 0.8 micrometer (pm) cellulose ester membrane air sampling cassettes with conductive cowl.

Analytical Procedures A section of the filter approximating twenty-five percent of the total filter was removed and placed on a pre-cleaned microscope slide and then exposed to approximately 260 microliter (pl) of acetone vapor. A single 3.0 - 3.5 pl drop of triacetin was applied and a clean #1.5 cover slip was placed upon the filter. The prepared slide was then heated on a slide heater until clarity allowed analysis to be conducted.

Analysis was accomplished utilizing a Phase Contrast Microscope in accordance with NIOSH 7400 method, counting rule "A."

Phase Contrast Microscopy JLC Environmental's laboratory uses an Olympus BH-PC Phase Contrast Microscope, (PCM) equipped with a Walton-Beckett Graticule. Samples were analyzed by first dissolving the filter through a chemical process (described above) and then counting the fibers with PCM at 400x magnification. Phase contrast increases the light contrast between the object and the background, thus enhancing the microscopist's ability to see fibers. Normally, 100 microscopic fields or 100 fibers are counted, whichever occurs first

Analytical Results "Summary of Analytical Results" represents the results of the analysis of the samples. The limit of reliable quantification is less than 0,01 fibers/cubic centimeter (f/cc) of air. If final tests do not meet these requirements, the entire work sits must be re-cleaned and re-tested.

CITY_DEP_WORBY_CANNATA_SUBP_000006534

NYC-WTC_000342685

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000342685Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

No available related records indexed in this group.

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Chain of custody, 01-2089

NYC-WTC_000390896

Chain-of-custody for air sampling analysis at 21 West Street.

Similar indexed content

Compare copies and versions →