NYC-WTC_000390887
Chain-of-custody for air sampling analysis at 21 West Street.
2 shared non-person entities · 1 shared topics · similarity 0.986
machine-extracted · confidence unavailable · Check page ↗General methodology description for air samples and lab processing.
NYC-WTC_000390846OCR status: ok · source: pdftotext
NYC 9/11 Public Portal Document FEB-28-2002 THU 11:01 AH CLOSINGS ® ROSE FAX NO. 212 210 6,'24 H. Jb/42
Rose Associates Inc. JLC Project #01-2089 October 23, ZOO I page? Air Sampling Analysis and Procedure
Introduction Air sampling is defined as the process of measuring the filter content of a known volume of air : entrained on a filter membrane over a specified period of time. Each sample is cross-referenced fay field designation and a JLC lab internal code to ensure proper, consistent handling through a chain of custody. Sample preparation takes place within an HEPA filter clean bench to avoid any possible contamination.
Methodology ‘Test proceduTes for these sarnies conform to the National Institute of Occupational Safety and Health (NIOSH) standards. 'I '1 Air sampling was conducted at a level approximating the breathing zone of persons anticipated to be present in the area during normal operations. Samples collected should represent the area's typical airhnrne fiber concentration.
All samples were collected on fully exposed 26 millimeter, 0.8 micrometer (pm) cellulose ester membrane air sampling cassettes with conductive cowl.
Analytical Procedures A soction of the filter approximating twenty-five percent of the total filter was remnvert and placed on a pre-cleaned microscope slide and then exposed to approximately 250 microliter (pl) of acetone vapor. A single 3.0 - 3.5 pl drop of triacetin was applied and a clean #1.5 cover slip was placed Upon the filter. The prepared slide was then heated on a slide heater until clarity allowed analysis to be conducted.
Analysis was accomplished utilizing a Phase Contrast Microscope in accordance with NIOSH 7400 method, counting lule "A."
Phase Contrast Microscopy JLC Environmental's laboratory uses an Olympus BH-PC Phase Contrast Microscope, (PCM) equipped with a Walton-Beckett Graticule. Samples were analyzed by first dissolving the filler through a chemical process (described above) and then counting the fibers with PCM at 400x magnification. Phase contrast increases the tight contrast between the object and the background, thus enhancing the microscopist’s ability to see fibers. Normally, 100 microscopic fields or 100 fibers are counted, whichever occurs first.
Analytical Results ■ The "Summar/ of Analytical Results" represents the results of the analysis of the samples. The i: PCM limit of reliable quantification is less than 0.01 fibers/cubic centimeter (f/cc) of air. If final tests do not meet these requliements, the entire work site must be re-cleaned and rc-tested.
CITY_21MC100_0 02388916 NYC-WTC_000390846
OCR can misread numbers and units. Confirm readings against the page image before using them.
Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.
NYC-WTC_000390887
Chain-of-custody for air sampling analysis at 21 West Street.
2 shared non-person entities · 1 shared topics · similarity 0.986
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000390889
Chain-of-custody for air sampling analysis at 21 West Street.
2 shared non-person entities · 1 shared topics · similarity 0.986
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000390896
Chain-of-custody for air sampling analysis at 21 West Street.
1 shared non-person entities · 1 shared topics · similarity 0.985
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000390904
Chain-of-custody for air sampling at 21 West Street.
1 shared non-person entities · 1 shared topics · similarity 0.985
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000390853
Analytical results for air samples from 21 West Street; PM/NIOSH/AIHA codes listed.
2 shared non-person entities · similarity 0.982
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000390867
Chain of custody for air sampling analyses by JLC.
1 shared non-person entities · similarity 0.980
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000390880
Chain-of-custody for air sampling analysis of asbestos fibers at building site.
2 shared non-person entities · 1 shared topics · similarity 0.980
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000390860
Chain of custody for air sampling at 21 West Street.
1 shared non-person entities · similarity 0.979
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000342723
Chain-of-custody form for air sampling at a New York site, documenting sample handling.
1 shared non-person entities · 1 shared topics · similarity 0.976
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000342704
Air sampling chain-of-custody for 100 [name], Dec 2001.
1 shared non-person entities · similarity 0.975
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000220454
Procedural document describing air sampling methods and chain of custody protocols for measuring airborne fiber concentrations at the site in September 2001.
1 shared non-person entities · 1 shared topics · similarity 0.975
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000342685
Air sampling chain-of-custody form for site sampling and handling procedures, Sept 2001.
1 shared non-person entities · 1 shared topics · similarity 0.973
machine-extracted · confidence unavailable · Check page ↗No available related records indexed in this group.
Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.
NYC-WTC_000390887
Chain-of-custody for air sampling analysis at 21 West Street.
Similarity score 0.993 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000390889
Chain-of-custody for air sampling analysis at 21 West Street.
Similarity score 0.993 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000094592
Multi-page chain of custody document tracking the handling of samples collected from 21 West Street.
Similarity score 0.993 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000094592
Multi-page chain of custody document tracking the handling of samples collected from 21 West Street.
Similarity score 0.993 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000094592
Multi-page chain of custody document tracking the handling of samples collected from 21 West Street.
Similarity score 0.992 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000390896
Chain-of-custody for air sampling analysis at 21 West Street.
Similarity score 0.992 (not a probability)
machine-extracted · confidence unavailable · Check page ↗Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.
NYC-WTC_000390887
Chain-of-custody for air sampling analysis at 21 West Street.
Similar indexed content
NYC-WTC_000390889
Chain-of-custody for air sampling analysis at 21 West Street.
Similar indexed content
NYC-WTC_000390896
Chain-of-custody for air sampling analysis at 21 West Street.
Similar indexed content
NYC-WTC_000390904
Chain-of-custody for air sampling at 21 West Street.
Similar indexed content
NYC-WTC_000390853
Analytical results for air samples from 21 West Street; PM/NIOSH/AIHA codes listed.
Similar indexed content