NYC Law Department release
Independent mirror · updated as the City releases more · v1.5.1
☕ Buy me a coffee
← Document results/Unboxed/No folder label
Document / 1 page

Chain of Custody, JLC project 01-2089, Oct 2001

Machine-extracted title · confidence 33%

Chain of custody for air sampling analyses by JLC.

NYC-WTC_000390867
Page image
Page image not rendered yet.
The pipeline renders page images incrementally; check back or read the OCR text alongside.
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document FEB-28-2Q02 THU 11:15 AM CLOSINGS • ROSE FAX NO. 212 210 6724 P. 29/42

FJoqe Aeeociates ' \ JLC Project#01-2089 ; : October 6, 2001 ■ page 2 Air Sampling Analysis and Procedure

Introduction 'i , Air sampling is defined as the process of measuring the filter content of a known volume of air entrained on a filter membrane over a specified period of time. Each sample is cross-referenced by field designation and a JLC lab internal code to ensure proper, consistent handling through a chain of custody. Sample preparation takes place within an HEPA filter clean bench to avoid any possible ' contamination.

4 Methodology •I , Test procedures for these samples conform tn the National Institute of Occupational Safety and Health (NIOSH) standards.

Air sampling was conducted at a level approximating the breathing zone of persons anticipated to be present in the area during normal operations. Samples collected should represent the area's typical airborne fiber concentration.

All samples ware coilected on tully exposed 25 millimeter, 0.8 micrometer (pm) cellulose esUr membrane air sampling cassettes with conductive cowl.

J ’ Analytical Procedures 1’'^ A section of the filter approximating twenty-five percent of the total filter was removed and placed on a pre-cleaned microscope slide and then exposed to approximately 250 microliter (pl) of acetone vapor. A single 3,0 - 3.5 pl drop of triacetin was applied and a clean #1.5 cover slip was placed upon tho filter. The prepared slide was then heated on a slide heater until clarity allowed analysis to be conducted. Analysis was accomplished utilizing a Phase Contrast Microscope in accordance with NIOSH 7400 method, counting rule "A,"

Phase Contrast Microscopy .It .C Environmental's laboratory uses an Olympus BH-PC Phase Contrast Microscope, (PCM) equipped with a Walton-Beckett Graticule. Samples were analyzed by first dissolving the filter through a chemical prococo (described above) and then counting the fibers with PCM at 400y magnification. Phase contrast increases the light contrast between the object and the background, thus enhancing the microscopist's ability to see fibers. Normally, 100 mioroscopic fields or 100 fibers are counted, whichever occurs first.

Analytical Results Tho "SuiTUnaiy of Analytical Results" represents the results of the analyeia of tho samples. The PCM limit of reliable quantification is less than 0.01 fibers/cubic centimeter (f/cc) of air. If final tests do not meet these requirements, the entire work site must be re-cleaned and re-tested,

'I

CITY_21MC100_002388939

NYC-WTC_000390867

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000390867Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

No available related records indexed in this group.

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Chain of custody, 01-2089

NYC-WTC_000390896

Chain-of-custody for air sampling analysis at 21 West Street.

Similar indexed content

Air sampling procedures documentation, Sept 2001

NYC-WTC_000220454

Procedural document describing air sampling methods and chain of custody protocols for measuring airborne fiber concentrations at the site in September 2001.

Similar indexed content

Compare copies and versions →