Insignia Residential Group, Inc.
JLG Project #01-2094
Septbmber 20, 2001
,age 2 Air Samplings Analysisand Procedure
Introduction
Air sampling is defined as the process of measuring the fifer content of a known
volume of air
entrained on a filter membrane over a specified period of time. Each sample is
field designation and a JLC lab internal code to ensure proper, consistent cross-referenced by
handling through a chain
of custody. Sample preparation takes place within an HEPA filter clean bench to
avoid any possible
contamination.
Methodology
Test procedures for these samples conform to the National Institute of Occupational
Health (NIOSH) standards. Safety and
Air sampling was conducted at a level approximating the breathing zone of
persons anticipated to
be present In the area during normal operations. Samples collected should
represent the area's
typical airborne fiber concentration.
All samples were collected on fully exposed 25 millimeter, 0.8 micrometer (pm) cellulose ester
membrane air sampling cassettes with conductive cowl.
J Analytical Procedures
A section of the filter approximating twenty-five percent of the total filter
was removed and placed on
a pre-cleaned microscope slide and then exposed to approximately 250
microliter (pl) of acetone
vapor. A single 3.0 - 3.5 pl drop of triacetin was applied and a clean #1.5
cover slip was placed
upon the filter. The prepared slide was then heated on a slide heater until
be conducted. clarity allowed analysis to
Analysis was accomplished utilizing a Phase Contrast Microscope in accordance
with NIOSH 7400
method, counting rule "A."
Phase Contrast Microscopy
JLC Environmental's laboratory uses an Olympus 811-PC Phase Contrast
Microscope, (PCM)
equipped with a Waiton-Beckett Graticule. Samples were analyzed by first
through a chemical process (described above) and then counting the fibers dissolving the filter
with PCM at 400x
magnification. Phase contrast increases the light contrast between the object and
thus enhancing the microscopists ability to see fibers. Normally, 100 the background,
fibers are counted, whichever occurs first microscopic fields or 100
Analytical Results
Th+e "Summary of Analytical Results" represents
the results of the analysis of the samples. The
limit of reliable quantification is less than 0.01 fiberstcubic centimeter
do not meet these requirements, the entire work site must be re (f/cc) of air. If final tests
-cleaned and re-tested.