Bulk sampling and air monitoring scope, Building 100

Machine-extracted title · confidence 43%

ALC scope: bulk samples and TEM air monitoring across Building 100, Oct 2001.

NYC-WTC_000342675–000342676
Page image
Page image not rendered yet.
The pipeline renders page images incrementally; check back or read the OCR text alongside.
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document

TAL The First Choice for Environmental Testing & Consulting OHP £ D

October 16. 2001

Gateway Plaza Management Corporation 375 South End Avenue New York., New York 10280 Via Facsimile

Subject: Gateway Plaza Building #400

Gentlemen;

ALC Environmental Incorporated (ALC) has been retained to perform bulk sampling, visual assessments & air monitoring according to the EPA Protocol to determine the presence of asbestos at the above referenced project. Every apartment in the building was assessed by our inspectors for dust and debris. Any area where visible dust and -te debris was found, ALC’s inspectors took a bulk sample, which was then sent to a third party independent laboratory for analysis. In most cases there was insufficient debris to sample and a visual assessment only was performed. Additionally, air sampling was performed using TEM Methodology on every floor in the building. .t ■ ■

Twelve (12) initial background air samples were collected and analyzed at building 400. Twelve (12) samples were analyzed via phase contrast microscopy (PCM) and two (2) were analyzed via Transmission Electron Microscopy (TEM). All were below the permissible limits

Based on EPA Guidelines, we collected one hundred fifty-eight (158) bulk samples and analyzed them via Polarized Light Microscopy (PLM) Methodology. One (1) sample collected from one apartment was found to be slightly above the regulatory limits of 1%. Zero (0) were found to be above the regulatory limits upon further analysis at a second laboratory for quality control purposes. However, certified asbestos abatement a contractors hired independently by the owner, were used to clean the specific apartment and the areas were cleared by ALC via TEM air sampling. All air samples were found to be well below the permissible limits and the tenants where this cleaning took place have been notified of the clearance.

ALC then collected air samples on every floor in the building. The air sampling and analysis was done utilizing applicable Federal, State and City Regulations pertaining to asbestos to include Federal OSHA (29 CFR 1926.58) EPA NESHAPS (40 CFR PART 61), AND TSCA TITLE H AHERA/ASHARA (40 CFR PART 763) Asbestos Regulations; the New York State Department of Labor Industrial Code Rule 56 and the New York City Department of Environmental Protection Title 15 Asbestos Regulations.

«st 30th Street • 11th Floor • New York, New York 10001 • 212.279.1001 • 888.466.3620 • Fax: 212.279.6747 I'ce; The Bellevue • Suite 600 • 200 S Broad Street • Philadelphia. P.A 19102 • 215.732.9499 • 888 789.8378 • Fax: 215.732.9559

I www.ALCEnvironmental com

CITY_DEP_WORBY_CANNATA_SUBP_000006498

NYC-WTC_000342675

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000342675Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

No available related records indexed in this group.

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Compare copies and versions →