Bulk sampling and air testing plan, *******

Machine-extracted title · confidence 25%

Asbestos bulk sampling and air monitoring plan for Building #300 under EPA protocol.

NYC-WTC_000409506–000409507
Page image
Page image not rendered yet.
The pipeline renders page images incrementally; check back or read the OCR text alongside.
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document

ENVfKONMEfTAL I N C O R P TEO The First Choice for Environmental Testing & Consulting

October 17. 2001

Gateway Plaza Management Corporation 375 South End Avenue Nev/ York. New York 10280

Subiect; Gateway Plaza Building #300

Gentlemen:

ALC Environmental Incorporated (ALC) has been retained to perform bulk sampling, visual assessments & air monitoring according to the EPA Protocol to determine the presence of asbestos at the above referenced project. Every apartment in the building was assessed by our inspectors for dust and debris. Any area where visible dust and debris was found, ALC’s inspectors look a bulk sample, which was then sent to a third party independent laboratory for analysis. In most cases there was msut’iicien! debns lo sample and a visual assessment only was performed. Additionally, air sampling was performed using TEM Methodology on every floor in the building

Twelve (12) initial background air samples were collected and analyzed via phase contrast microscopy (PCM) at building 300. Seven (7) samples were analyzed via Transmission Electron Microscopy (TEM). Afterjnalysis via rEM;all werebelow the permissible limits.

Based on EPA Guidelines, we collected six (6) bulk samples and analyzed them via Polaidzed Light Microscopy (PLM) Methodology. Zero (0) were found to be above the regulatory limits.

ALC then collected air samples on every floor in the building. The air sampling and analysis was done utilizing applicable Federal, State and City Regulations pertaining to asbestos to include Federal OSHA (29 CFR 1926.58) EPA NESHAPS (40 CFR PART 61), AND TSCA TITLE H AHERA/ASHARA (40 CFR PART 763) Asbestos Regulations; the New York State Department of Labor Industrial Code Rule 56 and the New York City Department of Environmental Protection Title 15 Asbestos Regulations.

Thiny (30) air samples were collected and analyzed via TEM Methodology. The results indicated that the living areas achieved the acceptance criteria below <70 structures per mmZ set by the above regulations.

1 15 Wesi 30th Street • 11th Floor • New York. New York 1000! • 212.270.1001 • 888,400 3820 • Fxx: 212.279 6747

Home t)llice: The Bellevue • Suiic 800 • ,00 S Broad Streei • Phibdclphu PA NIO? • 215 752 Auuo . 7HQ,557,s • Fax 215 752 9539

vvuH A/( En\‘n

CONFIDENTIAL, CITY_2IMCl00_003385343 SUBJECT TO PROTECTIVE ORDER NO. 2, SEPT. 2008

NYC-WTC_000409506

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000409506Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

No available related records indexed in this group.

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

NYC-WTC_000342648

ALC subcontract: bulk sampling, visual assessments, and air monitoring for Building #300.

Similar indexed content

NYC-WTC_000342625

Correspondence about bulk sampling, visual assessments, and air monitoring at Building #500.

Similar indexed content

Compare copies and versions →