NYC-WTC_000409221
Project description for asbestos bulk sampling and air monitoring at Building 500.
12 shared non-person entities · 1 shared topics · similarity 0.997
machine-extracted · confidence unavailable · Check page ↗Agency describes bulk sampling, visual assessment, and air monitoring for asbestos at Building 500.
NYC-WTC_000409192–000409193OCR status: ok · source: pdftotext
NYC 9/11 Public Portal Document
ENVIRONi 7U. The First Choice for Environmental Testing & Consulting INCORPORATED
October 22. 2001
Gateway Plaza Management Corporation 375 South End Avenue New York, New York 10280
Subject: Gateway Plaza Building #500
Gentlemen;
ALC Environmental Incorporated (ALC) has been retained to perform bulk sampling, visual assessments & air monitoring according to the EPA Protocol to determine the presence of asbestos at the above referenced project. Every apartment in the building was assessed by our inspectors for dust and debris. Any area where visible dust and debris was found, ALC’s inspectors took a bulk sample, which was then sent to a third party independent laboratory for analysis. In most cases there was insufficient debris to sample and a visual assessment only was performed. Additionally, air sampling was performed using TEM Methodology on every floor in the building.
Eight (8) initial background air samples were collected and analyzed at building 500. Eight (8) were analyzed via phase contrast microscopy (PCM) and four (4) were analyzed via transmission electron microscopy (TEM). After analysis via TEM, all were below the permissible limits.
Based on EPA Guidelines, we collected forty-six (46) bulk samples and analyzed them via Polanzed Light Microscopy (PLM) Methodology. Zero (0) were found to be above the regulatory limits
ALC then collected air samples on every floor in the building. The air sampling and analysis was done utilizing applicable Federal, State and City Regulations pertaining to asbestos to include Federal OSHA (29 CFR 1926.58) EPA NESHAPS (40 CFR PART 61), AND TSCA TITLE H AHERA/ASHARA (40 CFR PART 763) Asbestos Regulations; the New York State Department of Labor Industrial Code Rule 56 and the New York City Department of Environmental Protection Title 15 Asbestos Regulations.
Thirty-five (35) air samples were collected and analyzed via TEM Methodology. The results indicated that the living areas achieved the acceptance criteria below <70 structures per mm2 set by the above regulations.
1 15 West JOth Street ’ 1 1th Floor ‘ New York. New York lUOOl • 212 274 1001 • 88S -IbO 5020 > Fj\ 212 274 6747
. The BcilcMiL ’ Mute oOO ' 200 s Broad Sircct ’ Philadelphia PA P>102 ' 2 1 t 12 4440 . SHK , SO s >, s • fax 215 752 4554
wiviv \LCEin iiiinmoual mitt
CONFIDENTIAL, CITY_21MC100_003384912 SUBJECT TO PROTECTIVE ORDER NO. 2, SEPT. 2008
NYC-WTC_000409192
OCR can misread numbers and units. Confirm readings against the page image before using them.
Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.
NYC-WTC_000409221
Project description for asbestos bulk sampling and air monitoring at Building 500.
12 shared non-person entities · 1 shared topics · similarity 0.997
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000409132
ALC assessment describing bulk sampling, visual survey, and air monitoring for Building 100.
12 shared non-person entities · 1 shared topics · similarity 0.997
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000409161
ALC scope note: bulk sampling, visual assessments, and air monitoring at Building 100.
12 shared non-person entities · 1 shared topics · similarity 0.995
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000342625
Correspondence about bulk sampling, visual assessments, and air monitoring at Building #500.
12 shared non-person entities · 1 shared topics · similarity 0.995
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000342682
ALC bulk sampling and TEM air monitoring for Building 100, Oct 2001.
11 shared non-person entities · 1 shared topics · similarity 0.994
machine-extracted · confidence unavailable · Check page ↗12 shared non-person entities · 1 shared topics · similarity 0.993
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000409506
Asbestos bulk sampling and air monitoring plan for Building #300 under EPA protocol.
12 shared non-person entities · 1 shared topics · similarity 0.993
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000342648
ALC subcontract: bulk sampling, visual assessments, and air monitoring for Building #300.
12 shared non-person entities · 1 shared topics · similarity 0.992
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000409700
Summary of bulk sampling, visual assessments, and air monitoring per EPA protocol for asbestos at Building 400.
11 shared non-person entities · similarity 0.986
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000342675
ALC scope: bulk samples and TEM air monitoring across Building 100, Oct 2001.
12 shared non-person entities · similarity 0.986
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000229732
Memo describing bulk sampling and air monitoring procedures for asbestos at Building 400 in October 2001.
10 shared non-person entities · similarity 0.983
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000409435
Final air assessment for Building 600; bulk and TEM results summarized.
10 shared non-person entities · 1 shared topics · similarity 0.979
machine-extracted · confidence unavailable · Check page ↗No available related records indexed in this group.
Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.
NYC-WTC_000121409
Document tracking environmental samples collected from Building #500 at 385 South End Avenue on October 22, 2001.
Similarity score 0.998 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000120991
Record documenting the transfer and custody of air samples from Building #100 at 345 South End Avenue collected on October 22, 2001.
Similarity score 0.997 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000409132
ALC assessment describing bulk sampling, visual survey, and air monitoring for Building 100.
Similarity score 0.997 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000409221
Project description for asbestos bulk sampling and air monitoring at Building 500.
Similarity score 0.997 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000342682
ALC bulk sampling and TEM air monitoring for Building 100, Oct 2001.
Similarity score 0.996 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000409506
Asbestos bulk sampling and air monitoring plan for Building #300 under EPA protocol.
Similarity score 0.996 (not a probability)
machine-extracted · confidence unavailable · Check page ↗Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.
NYC-WTC_000409221
Project description for asbestos bulk sampling and air monitoring at Building 500.
Similar indexed content
NYC-WTC_000409132
ALC assessment describing bulk sampling, visual survey, and air monitoring for Building 100.
Similar indexed content
NYC-WTC_000409161
ALC scope note: bulk sampling, visual assessments, and air monitoring at Building 100.
Similar indexed content
Correspondence about bulk sampling, visual assessments, and air monitoring at Building #500.
Similar indexed content
NYC-WTC_000342682
ALC bulk sampling and TEM air monitoring for Building 100, Oct 2001.
Similar indexed content