10 shared non-person entities · 1 shared topics · similarity 0.979
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000205639
Label derived from the City's folder field. The City does not supply document titles.NYC-WTC_000205639–000205640
OCR status: ok · source: pdftotext
NYC 9/11 Public Portal Document
CENTAL /> ate 0 The First Choice for Environmental Testing & Consulting
October 9. 2001
Gateway Plaza Management Corporation 375 South End Avenue New York. New York 10280 Via Facsimile
Subject; Gateway Plaza Building #200
Gentlemen;
ALC Environmental Incorporated (ALC) has been retained to perform bulk sampling, visual assessments & air monitoring according to the EPA Protocol to determine the presence of asbestos at the above referenced project. Every apartment in the building was assessed by our inspectors for dust and debris. Any area where visible dust and debris was found, ALC’s inspectors took a bulk sample, which wa.s then sent to a third party independent laboratory for analysis. In most cases there wa.s insufficient debris to sample and a visual assessment only was performed. Additionally, air sampling was performed using TEM Methodology on every floor in the building
Twenty-one (21) initial background air samples were collected and analyzed at building 200. Twenty-one (21) were analyzed via phase contrast microscopy (PCM) and twelve (12) were re-analyzed via transmission electron microscopy (TEM). All were below the pernussiblelimits. I Based on EPA Guidelines, we collected one hundred ninety-nine (199) bulk samples and analyzed them via Polarized Light Microscopy (PLM) Methodology. Sixteen (16) samples collected from six (6) apartments were found to be slightly above the regulatory limits of 1%. Of the sixteen (16) bulk samples that were found to be above the limits, zero (0) were found to be above the regulatory limits upon further analysis at a second laboratory for quality control purposes. However, certified asbestos abatement contractors hired independently by the owner, were used to clean those specific apartments found to be in question and the areas were cleared by ALC via TEM samp 1 ing. All air samples were found to be well below the permissible limits and the tenants where this cleaning took place have been notified of the clearance.
ALC then collected air samples on every floor in the building. The air sampling and analysis was done utilizing applicable Federal, State and City Regulations pertaining to asbestos to include Federal OSHA (29 CFR 1926.58) EPA NESHAPS (40 CFR PART 61). AND TSCA TITLE H AHERA/ASHARA (40 CFR PART 763) Asbestos
I- it 30th Street • 11 th Floor • Sc'A Virk. New York 10001 » 212 27U 1001 • ,SH.S 4hfi 5ti2O • Fa.\ 2I2.27UO747 ■ ’ '’'Hive: rhe Bellevue • Suiie fiOO • 200 '' Broad sireei • Philadelphia P \ H102 • 215'12 • sH.s '.su s 17,4 • I .i\ 215'12
I rvuu .AL( En v i' iHirncnril/,. mi
CITY_DEP_WORBY_CANNATA_SUBP_000006452
NYC-WTC_000205639
OCR can misread numbers and units. Confirm readings against the page image before using them.
Related records
Browse subjects →Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.
Same-box records
12 shared non-person entities · 1 shared topics · similarity 0.970
machine-extracted · confidence unavailable · Check page ↗12 shared non-person entities · similarity 0.952
machine-extracted · confidence unavailable · Check page ↗5 shared non-person entities · similarity 0.948
machine-extracted · confidence unavailable · Check page ↗Filed elsewhere
NYC-WTC_000117493
Cover page for a report detailing annual assessment, bulk sampling, and air monitoring activities at the specified address.
12 shared non-person entities · 1 shared topics · similarity 0.970
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000117536
Chain of custody documentation for bulk sampling and air monitoring at 345 South End Avenue Building 100.
12 shared non-person entities · similarity 0.966
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000117723
Chain of custody documentation for bulk sampling and air monitoring at 365 South End Avenue Building 300.
12 shared non-person entities · 1 shared topics · similarity 0.965
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000117668
Chain of custody documentation for bulk sampling and air monitoring at 385 South End Avenue Building 500.
12 shared non-person entities · similarity 0.962
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000121065
Summary of air and dust sampling results collected from private residences and common areas at 250 South End Avenue.
4 shared non-person entities · 1 shared topics · similarity 0.951
machine-extracted · confidence unavailable · Check page ↗8 shared non-person entities · similarity 0.950
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000095478
Cover page for an air monitoring and bulk sampling report for Building #200 at 375 South End Avenue.
12 shared non-person entities · 1 shared topics · similarity 0.950
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000117757
Cover page for a report detailing annual assessment, bulk sampling, and air monitoring activities at the specified address.
11 shared non-person entities · similarity 0.946
machine-extracted · confidence unavailable · Check page ↗More like this page
Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.
NYC-WTC_000095208
Documentation tracking the chain of custody for environmental samples collected from Building #400 at 375 South End Avenue in October 2001.
Similarity score 0.996 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000095331
Chain of custody form documenting bulk sampling and air monitoring at 375 South End Avenue on November 17, 2001.
Similarity score 0.995 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000121516
Document tracking environmental samples collected from Building #600 at 395 South End Avenue on January 2, 2002.
Similarity score 0.995 (not a probability)
machine-extracted · confidence unavailable · Check page ↗Similarity score 0.994 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000095478
Cover page for an air monitoring and bulk sampling report for Building #200 at 375 South End Avenue.
Similarity score 0.994 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000119863
Document tracking environmental samples collected from 365 South End Avenue on October 17, 2001.
Similarity score 0.993 (not a probability)
machine-extracted · confidence unavailable · Check page ↗Others also read
Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.
Similar indexed content
Cover page for a report detailing annual assessment, bulk sampling, and air monitoring activities at the specified address.
Similar indexed content
Similar indexed content
Chain of custody documentation for bulk sampling and air monitoring at 345 South End Avenue Building 100.
Similar indexed content
Chain of custody documentation for bulk sampling and air monitoring at 365 South End Avenue Building 300.
Similar indexed content