NYC 9/11 Public Portal Document
I N C oO A~T ED The First Choice for Environmental Testing & ConsuIting
October 9. 2001
Gateway Plaza Management Corporation
375 South End Avenue
New York, New York 10280 Via Facsimile
Subject: Gateway Plaza Building #200
Gentlemen:
ALC Environmental Incorporated (ALC) has been retained to perform bulk sampling,
visual assessments & air monitoring according to the EPA Protocol to determine the
presence of asbestos at the above referenced project. Every apartment in the building
was assessed by our inspectors for dust and debris. Any area where visible dust and
debris was found, ALC's inspectors took a bulk sample, which was then sent to a third
party independent laboratory for analysis. In most cases there was insufficient debris to
sample and a visual assessment only was performed. Additionally, air sampling was
performed using TEM Methodology on every floor in the building.
Twenty-one (21) initial background air samples were collected and analyzed at building
200. Twenty-one (21) were analyzed via phase contrast microscopy (PCM) and twelve
(12) were re-analyzed via transmission electron microscopy (TEM). All were below the
permissible limits.
Based on EPA Guidelines, we collected one hundred ninety-nine (199) bulk samples and
analyzed them via Polarized Light Microscopy (PLM) Methodology. Sixteen (16)
samples collected from six (6) apartments were found to be slightly above the regulatory
limits of 1%. Of the sixteen (16) bulk samples that were found to be above the limits,
zero (0) were found to be above the regulatory limits upon further analysis at a second
laboratory for quality control purposes. However, certified asbestos abatement
contractors hired independently by the owner, were used to clean those specific
apartments found to be in question and the areas were cleared by ALC via TEM
sampling. All air samples were found to be well below the permissible limits and the
tenants where this cleanine took place have been notified of the clearance.
ALC then collected air samples on every floor in the building. The air sampling and
analysis was done utilizing applicable Federal, State and City Regulations pertaining to
asbestos to include Federal OSHA (29 CFR 1926.58) EPA NESHAPS (40 CFR PART
61), AND TSCA TITLE II AHERA/ASHARA (40 CFR PART 763) Asbestos
115 West 30th Street • 11th Floor • New York, New York 10001 • 212.279.1001 • 888.466.3620 • Fax: 212.279.6747
Home Office: The Bellevue • Suite 000 • 200 S. Broad Street • Philadelphia. PA 19102 • 215 732.9499 • 888.789.8378 • Fax: 215.732.9559
www.ALCEnvtronni ental.tom
NYC-WTC 000095614