NYSDOL - DOSH Regulations - Reg Page 27 of 44 be used for passage during work shall also be sealed.

(k) Isolation barners-specific.Separation of the work area from the remainder of the work site by construction of isolation barriers shall be accomplished as follows:

(1) Wall construction. Walls shall be constructed of wood or metal fl-aming to support barriers in all openings larger than 32 square feet, except where any one dimension is one foot or less.

(2) Sheathing thickness. A sheathing material of at least 3/8 -inch thickness shall be applied to the work side of the barrier.

(3) Sealing of partitions. Edges of the partition shall be caulked at the floor, ceiling, walls and fixtures to form an airtight seal.

(4) Plastic sheeting. The work area side of the partition shall be covered with a double layer of at least six-mil fire-retardant plastic sheeting with staggered joints and sealed.

(5) Plasticizing/sealing. All floor, wall and ceiling surfaces shall be covered with a minimum of two layers of at least six-mil fire-retardant plastic sheeting. The floor shall be plasticized first, and its plastic sheeting shall extend up the walls a distance of at least 12 inches on all sides. The walls shall then be plasticized by applying plastic sheeting from ceiling to floor, thus overlapping the floor sheeting by at least 12 inches. This process shall be repeated for the second layer of plastic sheeting for the floor and walls. All seams within a layer shall be separated by a distance of at least six feet and sealed airtight. All seams between layers shall be staggered.

(1) Removal of mounted objects.After isolation barriers are in place, objects such as light fixtures, electrical tracks, alarm systems, ventilation equipment and other items not previously sealed, shall be removed and HEPA-vacuumed. Localized HEPA-filtered vacuum equipment shall be used during fixture removal to reduce asbestos dispersal.

(m) Removal of ceilings. Suspended ceiling tiles and T-grid components contaminated with asbestos material shall remain in place until the work area has been plasticized and personal and equipment decontamination enclosures have been constructed. The tiles and components shall then be removed and disposed of as asbestos waste.

(n) Exits.Emergency and fire exits from the work area shall be maintained or alternate exits shall be established according to all applicable codes.

(o) Boiler areas. When abatement is to be performed within a boiler room, boilers shall be shut down and the burner and boiler accesses and breechings shall be sealed until abatement is completed and satisfactory clearance air-monitoring results have been achieved.

(p) Elevator shutdown or isolation.Elevators running through the work area shall be shut down except as noted in this subdivision.

(1) Isolation-detail. In projects where the elevator cannot be shut down, the hoist-way door frames shall be enclosed with nominal 2ft. x 4ft. framing, 16 inches center-to-center, covered with5/8-inch sheathing, preferably plywood or similar building material, and caulked at all seams. The enclosures shall be covered with two seamless layers of at least six-mil plastic sheeting, taped and sealed airtight. A final larger layer of at least six-mil plastic sheeting shall be taped airtight, but with slack, forming a larger perimeter diaphragm to sense air movement caused by the elevator operation.

(2) Elevator shaft ports. Elevator shaft ports, for pressure equalization when within the work area, shall be http://www.labor.state.ny.us/html/safety/s56.htm 01/20/2001

CITY_21MC100_012156419

NYC-WTC_000340394

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000340394Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

No available related records indexed in this group.

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

NYC-WTC_000446470

State Part 56 asbestos chain-of-custody/document referencing NY Department of Labor; NYC files.

Similar indexed content

Compare copies and versions →