NYC-WTC_000453278
Chain-of-custody for asbestos-related samples under Part 56 rules in NYC WTC context.
17 shared non-person entities · 1 shared topics · similarity 0.978
machine-extracted · confidence unavailable · Check page ↗New York DOSH Part 56 asbestos regulations and definitions.
NYC-WTC_000340368–000340411OCR status: ok · source: pdftotext
NYC 9/11 Public Portal Document
NYSDOL - DOSH Regulations - Reg Page 28 of 44 vented to the outside or nonwork areas using oversized solid-walled ducts or chambers constructed of a minimum of 3/8-inch sheathing over nominal 2ft. x 4ft. framing, 16 inches center-to-center. The joints shall be caulked and the ducts or chambers shall be sealed with two layers of at least six-mil fire-retardant plastic sheeting and duct tape. The first layer of plastic sheeting shall be attached to the ducts or chambers using a spray adhesive. This system shall be subjected to and pass a negative pressure test daily.
(q) Toilet facilities.Adequate toilet facilities shall exist, either in the clean area of the personal decontamination enclosure or shall be readily accessible to the personal decontamination enclosure.
Historical Sec. filed July 7, 1987; amds. filed; Oct. 18, 1991; Oct. 25, 1994 eff. Nov. 9, 1994. Amended Note: (d). § 56-8.2 Demolition-large and small asbestos projects.
(a) Timing-removal of salvage.Removal of nonporous, nonmovable salvage from a full or partial demolition with asbestos material in evidence shall occur after isolation barriers and decontamination enclosures are in place in that portion of the building or structure, and only after the salvage has been wet-cleaned and/or HEPA- vacuumed.
(b) Flooring.On demolition projects^ flooring shall be made watertight.
(c) Chimney effects.On demolition projects, all chimney effects in stacks, columns, flues, shafts and double walled enclosures shall be eliminated by sealing the accesses.
(d) Specific requirements.Demolition projects shall comply with section 56-8.1(a)-(f) and (i)-(q) of this Subpart.
(e) Enclosure projects.Prior to the placement of isolation barriers, surfaces to be enclosed shall be cleaned using HEPA-filtered vacuum equipment and/or wet cleaning.
Historical Note: Sec. filed July 7, 1987 eff. July 28, 1987. § 56-8.3 Minor asbestos projects.
(a) Vacation of work areas.All project areas shall be vacated by the occupants prior to work area preparation and until full abatement has been achieved.
(b) Isolation of work area.The project area shall be isolated by cordoning it off with barrier tape or line and shall be accessible through only one entrance/exit.
(c) Signs.Caution signs shall be posted at any location and approaches to a location wherever airborne concentrations of asbestos may exceed ambient background levels. Signs shall be posted that permit a person to read the sign and take the necessary protective measures to avoid exposure.
Historical Note: Sec. filed July 7, 1987; amd. filed Oct. 18, 1991 eff. Jan. 1, 1992. Subpart 56-9. PERSONAL DECONTAMINATION ENCLOSURE SYSTEM
Historical Note: Subpart (§§56-9.1-56-9.2) filed July 7, 1987 eff. July 28, 1987. § 56-9.1 Large asbestos projects.
(a) Enclosure-general.Personal decontamination enclosure systems shall be provided outside and attached to all locations where persons will enter or exit the work area. One system at a single location for each contained work area shall be required. Such systems may consist of existing rooms outside of the work area, if the layout is appropriate, that can be enclosed in plastic sheeting and are accessible from the work area. When this
http;//www.labor.state.ny.us/html/safety/s56.htm 01/20/2001
CITY_21MC100_012156420
NYC-WTC_000340395
OCR can misread numbers and units. Confirm readings against the page image before using them.
Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.
No available related records indexed in this group.
NYC-WTC_000453278
Chain-of-custody for asbestos-related samples under Part 56 rules in NYC WTC context.
17 shared non-person entities · 1 shared topics · similarity 0.978
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000437549
Asbestos chain-of-custody record for NYC WTC project, including state code reference.
17 shared non-person entities · 1 shared topics · similarity 0.978
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000443384
State regulation reference: Part 56 of Title 12 NYCRR, asbestos compliance document.
17 shared non-person entities · 1 shared topics · similarity 0.978
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000446470
State Part 56 asbestos chain-of-custody/document referencing NY Department of Labor; NYC files.
17 shared non-person entities · 1 shared topics · similarity 0.978
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000450663
City asbestos regulatory document referencing NYS Part 56; file with NYC-WTC code tag.
17 shared non-person entities · 1 shared topics · similarity 0.978
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000448811
New York City Part 56 asbestos documentation, NYC-WTC.
17 shared non-person entities · 1 shared topics · similarity 0.978
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000438568
Page 1 of a chain-of-custody form referencing NY CRR Part 56 and the NYC WTC records.
17 shared non-person entities · 1 shared topics · similarity 0.978
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000448332
DOL 12 NYCRR Part 56 reference and regulatory context for asbestos.
17 shared non-person entities · 1 shared topics · similarity 0.978
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000441450
Asbestos standards reference page from NY Department of Labor materials.
17 shared non-person entities · 1 shared topics · similarity 0.978
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000233286
Chain of custody form for asbestos samples referencing New York State Department of Labor regulations and sample tracking details.
17 shared non-person entities · 1 shared topics · similarity 0.978
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000451646
Asbestos Part 56 inspection reference document, NYC.
17 shared non-person entities · 1 shared topics · similarity 0.978
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000411802
COSH-related NYC RO regulatory chapter on asbestos control.
16 shared non-person entities · 1 shared topics · similarity 0.974
machine-extracted · confidence unavailable · Check page ↗Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.
NYC-WTC_000453278
Chain-of-custody for asbestos-related samples under Part 56 rules in NYC WTC context.
Similarity score 0.965 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000453278
Chain-of-custody for asbestos-related samples under Part 56 rules in NYC WTC context.
Similarity score 0.963 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000438568
Page 1 of a chain-of-custody form referencing NY CRR Part 56 and the NYC WTC records.
Similarity score 0.963 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000448332
DOL 12 NYCRR Part 56 reference and regulatory context for asbestos.
Similarity score 0.963 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000094912
Invoice detailing billing for bulk and air sample analysis results including PLM, PCM, and TEM testing at 44 Wall Street.
Similarity score 0.962 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000443384
State regulation reference: Part 56 of Title 12 NYCRR, asbestos compliance document.
Similarity score 0.962 (not a probability)
machine-extracted · confidence unavailable · Check page ↗Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.
NYC-WTC_000453278
Chain-of-custody for asbestos-related samples under Part 56 rules in NYC WTC context.
Similar indexed content
NYC-WTC_000437549
Asbestos chain-of-custody record for NYC WTC project, including state code reference.
Similar indexed content
NYC-WTC_000443384
State regulation reference: Part 56 of Title 12 NYCRR, asbestos compliance document.
Similar indexed content
State Part 56 asbestos chain-of-custody/document referencing NY Department of Labor; NYC files.
Similar indexed content
NYC-WTC_000450663
City asbestos regulatory document referencing NYS Part 56; file with NYC-WTC code tag.
Similar indexed content