105 Duane Street Apartment 19E

The apartment has a fan coil unit in the bedroom and in the living room. The unit provides heating in the winter and cooling in the summer. Each fan coil unit has an outside air damper.

Vicky Lavergne has reported respiratory symptoms over the past year. Neither asbestos dust nor lead dust would cause respiratory symptoms, but concrete dust released during the collapse can cause respiratory irritation.

Methods Surface dust samples for the presence of asbestos were collected according to the method 5755-95 published by the American Society of Testing and Materials (ASTM). This involves drawing dust from a surface area of 100 square centimeters on a 0.8 micron mixed cellulose ester filter. The dust was collected using a personal sampling pump operated at 2 liters per minute. The filter is analyzed by transmission electron microscopy for asbestos fibers. All of the samples were shipped overnight and analyzed by lATL.

A wipe sample was taken for the presence of lead on the floor. The sample was taken with ghost wipes manufactured by Environmental Express and is designed for sampling surfaces for lead contamination following the ASTM method E 1792. The sample was taken across a 100 square centimeter area of the floor using disposable templates manufactured by SKC, Inc. The sample was analyzed by lATL using atomic absorption spectroscopy following the ASTM method.

A sample of water damaged wood flooring was taken from the living room beneath the air conditioner. There was evidence of visible mold growth on the sheetrock walls of the plenum in the bathroom exhaust shaft. The bulk sample was analyzed by PAK Microbiology Services, Inc using microscopic methods and by culturing on 2% malt extract agar.

Exposure Criteria Asbestos in Dust The ASTAA method is intended for guidance on examining dust contamination of building surfaces and is intended as a general assessment of the building. There is no suggestion in the ASTM method that it can be used to assess general health risk from asbestos exposure, nor does it suggest that all

3

CITY_21MC100_003062669

NYC-WTC_000337562

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000337562Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

No available related records indexed in this group.

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Buildings in this record

Machine-extracted building matches; verify each source. Buildings, never households.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Compare copies and versions →