Machine-extracted title · confidence 41%

Quality survey document prepared for 105 [address], Oct 7, 2002.

NYC-WTC_000337560–000337567
Page image
Page image not rendered yet.
The pipeline renders page images incrementally; check back or read the OCR text alongside.
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document

105 Duane Street Apartment 19E

building surfaces be maintained to the levels published in the standard. The method is generally applicable for the estimate of the concentration of asbestos fibers on surfaces starting from approximately 1000 fibers per square centimeter (f/cm2). This method does not provide information on the level of airborne exposure, but instead provides an assessment of the level of asbestos settled onto surfaces. As such it can only be used to assess the potential of exposure should contaminated dust become airborne.

It is important to note that asbestos “structures" (as defined by EPA) are not equivalent to asbestos "fibers" as defined by the Occupational Safety and Health Administration (OSHA). Asbestos fibers regulated by OSHA must be greater than 5.0 micrometers microns) in length, of large enough in diameter to be seen under PCM, and must have an aspect ratio of 3:1 or greater. Asbestos structures can be much smaller than "fiber" (since they are measured using TEM); "structures" generally include all asbestos fibers longer than 0.5 microns with an aspect ratio greater than 3:1 or in some cases, 5:1. The health effects of very small asbestos fibers are less clear cut than those known to be caused by fibers greater than 5 microns in length, but, in general, toxicity studies have shown that fibers shorter than 5 pm are less toxic than longer fibers.’

Some studies of settled dust measured via the microvac method have been reported in the literature. Millette and Hays review surface data through the early 199O's finding that typical carpet dust values in buildings with Asbestos Containing Material ranged from a few to millions of structures/cm^ via the microvac method. Overall, Millette and Hays suggest that levels of asbestos in settled dust determined by the microvac should be considered low if below 1,000 s/cm^, above background if >10,000 s/cm^, and high when >100,000 s/cm^. They also conclude that levels are highly dependent upon frequency of cleaning, with levels clearly lower when cleaning is frequent.

A more recent study by Ewing, et al,^ looked at some 85 buildings and found geometric mean asbestos levels for the following categories: outside dust— 5,100 s/cm^; buildings with no surfacing ACM—1,000 s/cm^; buildings with

' Health Effects Institute-Asbestos Research. Asbestos in public and commercial buildings: A literature review and synthesis of current knowledge. Cambridge, MA, 1991. ■ Ewing, WM, TA Dawson, GP Alber. Observations of settled asbestos dust in buildings. EIA Technical Journal, Summer 1996.

. '4

CITY_21MC100_003062670

NYC-WTC_000337563

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000337563Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

No available related records indexed in this group.

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Buildings in this record

Machine-extracted building matches; verify each source. Buildings, never households.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Compare copies and versions →