Asbestos measurement overview, Health & Mental Hygiene, 2001

Machine-extracted title · confidence 44%

Overview of asbestos measurement methods and standards (PCM/TEM) used for indoor/outdoor air.

NYC-WTC_000454475
Page image
Scanned page image, NYC-WTC_000454475
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document

How is asbestos being measured in and around the WTC site?

Airborne asbestos levels are measured in terms of asbestos fibers per cubic centimeter (f/cm^) or number of stiuctures per square millimeter (stnxctures/mm^). The United States Asbestos Hazard Emergency Response Act (AHERA) set the standard for children re-entering school buildings after asbestos removal or abatement as a maximum of 70 structures/mm^ or the equivalent of 0.01 fibers per cubic centimeter (O.Olf/cc) for indoor air. For workers, the United States Occupational Safety and Health Adininistration’s (OSHA) standard is 0.1 f/cc in air averaged over an 8-hour work-day. Because there is currently no standard for asbestos in outdoor air, the agencies are comparing the outdoor air asbestos results to the more stringent AHERA standard.

Asbestos levels in dust are measured as percent asbestos per amount of material. A level of 1% or higher is considered to be an asbestos-containing material (ACM).

There are two methods of analysis for airborne asbestos being utilized by scientists from the EPA, DEP and other agencies. One method, referred to as “PCM”, counts all fibers in the air which are of a size associated with health effects, but cannot distinguish between asbestos and non-asbestos fibers. The other method, “TEM” can distinguish between asbestos and non-asbestos fibers (for example, fiberglass) and can also detect thin asbestos fibers that may not be detected by the PCM method.

As air monitoring continues, it is possible that occasional short-term increases of asbestos levels above the AHERA standard of 0.01 f/cc or 70 sturctures / may be detected. Nevertheless, most outdoor air sampling results near the World Trade Center have been within the standards used for asbestos in indoor air.

CITY_21MC100_0 08825158

NYC-WTC_000454475

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000454475Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Compare copies and versions →